ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

After-pulsing, cross-talk, dark-count, and gain of MPPC under 7-T static magnetic field.

https://repo.qst.go.jp/records/47561
https://repo.qst.go.jp/records/47561
cdcec0ce-7991-401e-948b-44a227c6d0c7
Item type 学術雑誌論文 / Journal Article(1)
公開日 2016-10-05
タイトル
タイトル After-pulsing, cross-talk, dark-count, and gain of MPPC under 7-T static magnetic field.
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Hirano, Yoshiyuki

× Hirano, Yoshiyuki

WEKO 476721

Hirano, Yoshiyuki

Search repository
Nishikido, Fumihiko

× Nishikido, Fumihiko

WEKO 476722

Nishikido, Fumihiko

Search repository
Kokuryo, Daisuke

× Kokuryo, Daisuke

WEKO 476723

Kokuryo, Daisuke

Search repository
Yamaya, Taiga

× Yamaya, Taiga

WEKO 476724

Yamaya, Taiga

Search repository
平野 祥之

× 平野 祥之

WEKO 476725

en 平野 祥之

Search repository
錦戸 文彦

× 錦戸 文彦

WEKO 476726

en 錦戸 文彦

Search repository
國領 大介

× 國領 大介

WEKO 476727

en 國領 大介

Search repository
山谷 泰賀

× 山谷 泰賀

WEKO 476728

en 山谷 泰賀

Search repository
抄録
内容記述タイプ Abstract
内容記述 Multi-pixel photon counters (MPPCs) have been used instead of photomultiplier tubes for positron emission tomography combined with magnetic resonance (PET-MR). However, the effects of the magnetic field (MF) on the intrinsic properties-gain, cross-talk, after-pulsing, and dark-count-have not been sufficiently investigated. Therefore, we measured these properties for two types of MPPCs-S10931-50P and S12572-50P-in a static 7-T MF. These properties were measured with a pulse-shape analysis using pulse data acquired by a digital oscilloscope in the presence of the MF (w/MF) and the absence of the MF (w/o MF) by changing the supplied over-voltages (from 0.95 to 2.1 V for S10931 and from 2.1 to 3.3 V for S12572). No significant differences between the w/MF and w/o MF cases were observed for either MPPC, suggesting that the gain, cross-talk, after-pulsing, and dark-count are insensitive to a 7-T MF. The present work shows that constant MPPC performance is expected under a strong MF and demonstrates positive results for PET-MR.
書誌情報 Radiological physics and technology

巻 9, 号 2, p. 245-253, 発行日 2016-07
ISSN
収録物識別子タイプ ISSN
収録物識別子 1865-0333
PubMed番号
識別子タイプ PMID
関連識別子 27188511
DOI
識別子タイプ DOI
関連識別子 10.1007/s12194-016-0356-3
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:38:19.739905
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3