ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Lymph node mapping using quantum dot-labeled polymersomes

https://repo.qst.go.jp/records/47458
https://repo.qst.go.jp/records/47458
79dddda4-3a5d-4e51-9ffe-c50ab30ab0d5
Item type 学術雑誌論文 / Journal Article(1)
公開日 2016-08-10
タイトル
タイトル Lymph node mapping using quantum dot-labeled polymersomes
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Rumiana, Bakalova

× Rumiana, Bakalova

WEKO 475417

Rumiana, Bakalova

Search repository
Zhelov, Zhivko

× Zhelov, Zhivko

WEKO 475418

Zhelov, Zhivko

Search repository
Nikolova, Billiana

× Nikolova, Billiana

WEKO 475419

Nikolova, Billiana

Search repository
Murayama, Shuhei

× Murayama, Shuhei

WEKO 475420

Murayama, Shuhei

Search repository
Lazarova, Desislava

× Lazarova, Desislava

WEKO 475421

Lazarova, Desislava

Search repository
Tsoneva, Idana

× Tsoneva, Idana

WEKO 475422

Tsoneva, Idana

Search repository
Aoki, Ichio

× Aoki, Ichio

WEKO 475423

Aoki, Ichio

Search repository
Saga, Tsuneo

× Saga, Tsuneo

WEKO 475424

Saga, Tsuneo

Search repository
バカロバ ルミアナ

× バカロバ ルミアナ

WEKO 475425

en バカロバ ルミアナ

Search repository
村山 周平

× 村山 周平

WEKO 475426

en 村山 周平

Search repository
青木 伊知男

× 青木 伊知男

WEKO 475427

en 青木 伊知男

Search repository
佐賀 恒夫

× 佐賀 恒夫

WEKO 475428

en 佐賀 恒夫

Search repository
抄録
内容記述タイプ Abstract
内容記述 The present study was designed to investigate whether poly-ion complex hollow vesicles (polymersomes), based on chemically-modified chitosan, are appropriate for lymph node mapping in the context of their application in the development of theranostic nanosized drug delivery systems (nano-DDS). The experiments were performed on Balb/c nude mice (colon cancer-grafted). The mice were subjected to anesthesia and quantum dot (QD705)-labeled polymersomes (d~120 nm) were injected intravenously via the tail vein. The optical imaging was carried out on Maestro EX Imaging System (excitation filter: 435–480 nm; emission filter: 700 nm). A strong fluorescent signal, correspondingto QD705 fluorescence, was detected in thelymph nodes, as well as in the tumor. A very weak fluorescent signal was found in the liver area. The half-life of QD705-labelled polymersomeswas 6 ± 2 hours in the bloodstream and 11 ± 3 hours in the lymph nodes. The data suggest that polymersomes are very promising carriers for lymph node mapping using QD as a contrast agent. They are useful matrix for development of nano-formulations with theranostic capabilities.
書誌情報 General Physiology and Biophysics

巻 34, 号 4, p. 393-398, 発行日 2015-10
出版者
出版者 AEPress
ISSN
収録物識別子タイプ ISSN
収録物識別子 0231-5882
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:39:36.512471
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3