WEKO3
アイテム
Quantitative analysis of dopamine transporters in human brain using [11C]PE2I and positron emission tomography: evaluation of reference tissue models
https://repo.qst.go.jp/records/47328
https://repo.qst.go.jp/records/4732843432c94-5fcf-482d-9989-37151d7f52dd
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2015-11-13 | |||||
タイトル | ||||||
タイトル | Quantitative analysis of dopamine transporters in human brain using [11C]PE2I and positron emission tomography: evaluation of reference tissue models | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Seki, Chie
× Seki, Chie× Ito, Hiroshi× Ichimiya, Tetsuya× Arakawa, Ryosuke× Ikoma, Yoko× Shidahara, Miho× Maeda, Jun× Takano, Akihiro× Takahashi, Hidehiko× Kimura, Yuichi× Suzuki, Kazutoshi× Kanno, Iwao× Suhara, Tetsuya× 関 千江× 伊藤 浩× 一宮 哲哉× 荒川 亮介× 生駒 洋子× 志田原 美保× 前田 純× 高野 晶寛× 高橋 英彦× 木村 裕一× 鈴木 和年× 菅野 巖× 須原 哲也 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | OBJECTIVE: Dopamine transporter (DAT) is a reuptake carrier of dopamine at presynapse that regulates dopaminergic neural transmission. [(11)C]PE2I is a cocaine analog developed as a potent positron emission tomography (PET) ligand for DAT with high selectivity. The aim of this study was to evaluate the applicability of quantification methods using reference tissue models for [(11)C]PE2I. METHODS: Dynamic PET scans were performed in 6 young healthy male volunteers after an intravenous bolus injection of [(11)C]PE2I. Metabolite-corrected arterial plasma-input functions were obtained. Compartment model analysis and plasma-input Logan analysis were performed to determine the kinetic parameters and distribution volume (V (T)). The distribution volume ratio (DVR) was calculated as the ratio of V (T) in the cerebral region to that in the cerebellum. DVRs were also determined by the original multilinear reference tissue model method (MRTMo) and the simplified reference tissue model method (SRTM), comparing the results with those obtained from graphical analysis using arterial input function. To estimate errors in DVR calculated using the reference tissue model, a simulation study that focused on cerebellar kinetics and scan duration was performed. RESULTS: The highest [(11)C]PE2I binding was observed in the striatum, followed by the midbrain and thalamus. The 2-tissue model was preferable to the 1-tissue model for describing the [(11)C]PE2I kinetics in the cerebellum. Both the measured and 90-min simulated data showed that reference tissue models caused an underestimation of DVR in the striatum. The simulation showed that 90-min scan duration was insufficient when cerebellar kinetics was described as a 1-tissue model. Nevertheless, DVR values determined by MRTMo and SRTM were in good agreement with those by the graphical approach in other lower binding regions. CONCLUSION: Due to the [(11)C]PE2I kinetics in the cerebellum and limited scan duration for (11)C, MRTMo and SRTM underestimated the striatal DVR. Despite this limitation, the present study demonstrated the applicability of reference tissue models. Since DAT in the midbrain and thalamus is of interest in the pathophysiology of neuropsychiatric disease, this noninvasive quantitative analysis will be useful for clinical investigations. | |||||
書誌情報 |
Annals of Nuclear Medicine 巻 24, 号 4, p. 249-260, 発行日 2010-04 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0914-7187 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1007/s12149-010-0364-z |