ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Application of Al2O3:C+fibre dosimeters for 290 MeV/n carbon therapeutic beam dosimetry.

https://repo.qst.go.jp/records/47285
https://repo.qst.go.jp/records/47285
6c7c2cec-86b4-4890-a3e0-7ec22e3d8a8b
Item type 学術雑誌論文 / Journal Article(1)
公開日 2015-09-15
タイトル
タイトル Application of Al2O3:C+fibre dosimeters for 290 MeV/n carbon therapeutic beam dosimetry.
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Nascimento, L.F

× Nascimento, L.F

WEKO 472936

Nascimento, L.F

Search repository
Vanhavere, F.

× Vanhavere, F.

WEKO 472937

Vanhavere, F.

Search repository
Kodaira, Satoshi

× Kodaira, Satoshi

WEKO 472938

Kodaira, Satoshi

Search repository
Kitamura, Hisashi

× Kitamura, Hisashi

WEKO 472939

Kitamura, Hisashi

Search repository
D.Verellen

× D.Verellen

WEKO 472940

D.Verellen

Search repository
Deene, Y.De

× Deene, Y.De

WEKO 472941

Deene, Y.De

Search repository
Vangavere Filip

× Vangavere Filip

WEKO 472942

en Vangavere Filip

Search repository
小平 聡

× 小平 聡

WEKO 472943

en 小平 聡

Search repository
北村 尚

× 北村 尚

WEKO 472944

en 北村 尚

Search repository
抄録
内容記述タイプ Abstract
内容記述 The capability of radioluminescence (RL) dosimeters composed of carbon-doped aluminium oxide (Al2O3:C) detectors+optical fibre has been verified for absorbed dose-rate measurements during carbon radiotherapy. The RL signals from two separate Al2O3:C detectors (single crystal 'CG' and droplet 'P1') have been systematically measured and compared along the Bragg-curve and Spread-Out Bragg-Peak of 290 MeV/n carbon beams in the water. The absorbed dose response was assessed for the range of 0.5–10 Gy. For doses up to 6 Gy, we observed a linear response for both types of detectors, while for higher doses CG presented a more prominent supraliearity than P1. The RL response for low-LET protons in the entrance from the curve was found to closely resemble that observed for a clinical 6 MV X-ray beam, while it was found that P1 has a better agreement with the reference data from standard ionization chamber than CG. We observed a significant decrease in luminescence efficiency with LET in the Bragg peak region. The Al2O3:C RL luminescence efficiency differs from Al2O3:C OSL results, which implies that the signal can be corrected for LET dependency to match the correct SOBP and Bragg Peak.
書誌情報 Radiation Physics and Chemistry

巻 115, p. 75-80, 発行日 2015-10
出版者
出版者 Elsevier
ISSN
収録物識別子タイプ ISSN
収録物識別子 0969-806X
DOI
識別子タイプ DOI
関連識別子 10.1016/j.radphyschem.2015.06.001
関連サイト
識別子タイプ URI
関連識別子 http://www.sciencedirect.com/science/article/pii/S0969806X15002297
関連名称 http://www.sciencedirect.com/science/article/pii/S0969806X15002297
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:41:37.616384
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3