{"created":"2023-05-15T14:36:42.314219+00:00","id":47285,"links":{},"metadata":{"_buckets":{"deposit":"aab85a4f-7a40-48dc-af94-2f2ff737a478"},"_deposit":{"created_by":1,"id":"47285","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"47285"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00047285","sets":["1"]},"author_link":["472943","472938","472937","472940","472936","472939","472941","472942","472944"],"item_8_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2015-10","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"80","bibliographicPageStart":"75","bibliographicVolumeNumber":"115","bibliographic_titles":[{"bibliographic_title":"Radiation Physics and Chemistry"}]}]},"item_8_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"The capability of radioluminescence (RL) dosimeters composed of carbon-doped aluminium oxide (Al2O3:C) detectors+optical fibre has been verified for absorbed dose-rate measurements during carbon radiotherapy. The RL signals from two separate Al2O3:C detectors (single crystal 'CG' and droplet 'P1') have been systematically measured and compared along the Bragg-curve and Spread-Out Bragg-Peak of 290 MeV/n carbon beams in the water. The absorbed dose response was assessed for the range of 0.5–10 Gy. For doses up to 6 Gy, we observed a linear response for both types of detectors, while for higher doses CG presented a more prominent supraliearity than P1. The RL response for low-LET protons in the entrance from the curve was found to closely resemble that observed for a clinical 6 MV X-ray beam, while it was found that P1 has a better agreement with the reference data from standard ionization chamber than CG. We observed a significant decrease in luminescence efficiency with LET in the Bragg peak region. The Al2O3:C RL luminescence efficiency differs from Al2O3:C OSL results, which implies that the signal can be corrected for LET dependency to match the correct SOBP and Bragg Peak.","subitem_description_type":"Abstract"}]},"item_8_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"Elsevier"}]},"item_8_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1016/j.radphyschem.2015.06.001","subitem_relation_type_select":"DOI"}}]},"item_8_relation_17":{"attribute_name":"関連サイト","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"http://www.sciencedirect.com/science/article/pii/S0969806X15002297"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"http://www.sciencedirect.com/science/article/pii/S0969806X15002297","subitem_relation_type_select":"URI"}}]},"item_8_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0969-806X","subitem_source_identifier_type":"ISSN"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Nascimento, L.F"}],"nameIdentifiers":[{"nameIdentifier":"472936","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Vanhavere, F."}],"nameIdentifiers":[{"nameIdentifier":"472937","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kodaira, Satoshi"}],"nameIdentifiers":[{"nameIdentifier":"472938","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kitamura, Hisashi"}],"nameIdentifiers":[{"nameIdentifier":"472939","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"D.Verellen"}],"nameIdentifiers":[{"nameIdentifier":"472940","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Deene, Y.De"}],"nameIdentifiers":[{"nameIdentifier":"472941","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Vangavere Filip","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"472942","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"小平 聡","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"472943","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"北村 尚","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"472944","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Application of Al2O3:C+fibre dosimeters for 290 MeV/n carbon therapeutic beam dosimetry.","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Application of Al2O3:C+fibre dosimeters for 290 MeV/n carbon therapeutic beam dosimetry."}]},"item_type_id":"8","owner":"1","path":["1"],"pubdate":{"attribute_name":"公開日","attribute_value":"2015-09-15"},"publish_date":"2015-09-15","publish_status":"0","recid":"47285","relation_version_is_last":true,"title":["Application of Al2O3:C+fibre dosimeters for 290 MeV/n carbon therapeutic beam dosimetry."],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T23:41:37.496674+00:00"}