WEKO3
アイテム
Measurement of dose equivalent distribution on-board commercial jet aircraft
https://repo.qst.go.jp/records/46979
https://repo.qst.go.jp/records/469792867c680-ee6c-453c-9db8-21bc50254125
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2014-12-01 | |||||
タイトル | ||||||
タイトル | Measurement of dose equivalent distribution on-board commercial jet aircraft | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
J., Kubancˇa´k
× J., Kubancˇa´k× Ambrozˇova, I.× Ploc, O.× K., Pachnerova´ Brabcova× V.Sˇ, teˇpa´n× Uchihori, Y.× 内堀 幸夫 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | The annual effective doses of aircrew members often exceed the limit of 1 mSv for the public due to the increased level of cosmic radiation at the flight altitudes, and thus, it is recommended to monitor them [International Commission on Radiation Protection. 1990 Recommendations of the International Commission on Radiological Protection. ICRP Publication 60. Ann. ICRP 21(1–3), (1991)]. According to the Monte Carlo simulations [Battistoni, G., Ferrari, A., Pelliccioni, M. and Villari, R. Evaluation of the doses to aircrew members taking into consideration the aircraft structures. Adv. Space Res. 36, 1645–1652 (2005) and Ferrari, A., Pelliccioni, M. and Villari, R. Evaluation of the influence of aircraft shielding on the aircrew exposure through an aircraft mathematical model. Radiat. Prot. Dosim. 108(2), 91–105 (2004)], the ambient dose equivalent rate H_ ð10Þ depends on the location in the aircraft. The aim of this article is to experimentally evaluate H_ ð10Þ on-board selected types of aircraft. The authors found that H_ ð10Þ values are higher in the front and the back of the cabin and lesser in the middle of the cabin. Moreover, total dosimetry characteristics obtained in this way are in a reasonable agreement with other data, in particular with the above-mentioned simulations. |
|||||
書誌情報 |
Radiation Protection Dosimetry 巻 157, 号 4, p. 1-5, 発行日 2013-12 |
|||||
出版者 | ||||||
出版者 | Oxford University Press. | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0144-8420 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1093/rpd/nct331 | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | http://rpd.oxfordjournals.org/ | |||||
関連名称 | http://rpd.oxfordjournals.org/ |