A simultaneous space sampling method for DNA fraction collection using a comb structure in microfluidic devices.

https://repo.qst.go.jp/records/46976
https://repo.qst.go.jp/records/46976
722cf05e-80e2-46f0-bf64-049b1a12e5b5
Item type 学術雑誌論文 / Journal Article(1)
公開日 2014-12-01
タイトル
タイトル A simultaneous space sampling method for DNA fraction collection using a comb structure in microfluidic devices.
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Li, Zheyu

× Li, Zheyu

WEKO 468862

Li, Zheyu

Search repository
Sun, Kai

× Sun, Kai

WEKO 468863

Sun, Kai

Search repository
Sunayama, Misato

× Sunayama, Misato

WEKO 468864

Sunayama, Misato

Search repository
Araki, Ryoko

× Araki, Ryoko

WEKO 468865

Araki, Ryoko

Search repository
Ueno, Kosei

× Ueno, Kosei

WEKO 468866

Ueno, Kosei

Search repository
Abe, Masumi

× Abe, Masumi

WEKO 468867

Abe, Masumi

Search repository
Misawa, Hiroaki

× Misawa, Hiroaki

WEKO 468868

Misawa, Hiroaki

Search repository
砂山 美里

× 砂山 美里

WEKO 468869

en 砂山 美里

Search repository
荒木 良子

× 荒木 良子

WEKO 468870

en 荒木 良子

Search repository
安倍 真澄

× 安倍 真澄

WEKO 468871

en 安倍 真澄

Search repository
抄録
内容記述タイプ Abstract
内容記述 Fraction collection of selected components from a complex mixture plays a critical role in biomedical research, environmental analysis, and biotechnology. Here, we introduce a novel electrophoretic chip device based on a signal processing theorem that allows simultaneous space sampling for fractionation of ssDNA target fragments. Ten parallel extraction channels, which covered 1.5-mm-long sampling ranges, were used to facilitate the capturing of fast-moving fragments. Furthermore, the space sampling extraction made it possible to acquire pure collection, even from partly overlapping fragments that had been insufficiently separated after a short electrophoretic run. Fragments of 180, 181, and 182 bases were simultaneously collected, and then the recovered DNA was PCR amplified and assessed by CE analysis. The 181-base target was shown to be isolated in a 70-mm-long separation length within 10 min, in contrast to the >50 min required for the 300-mm-long separation channel in our previous study. This method provides effective combination of time and space, which is a breakthrough in the traditional concept of fraction collection on a chip.
書誌情報 Electrophoresis

巻 32, 号 23, p. 3392-3398, 発行日 2011-11
出版者
出版者 Wiley-VCH
ISSN
収録物識別子タイプ ISSN
収録物識別子 0173-0835
PubMed番号
識別子タイプ PMID
関連識別子 22072547
DOI
識別子タイプ DOI
関連識別子 10.1002/elps.201100362
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:45:23.289403
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3