ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Measuring the vascular diameter of brain surface and parenchymal arteries in awake mouse.

https://repo.qst.go.jp/records/46908
https://repo.qst.go.jp/records/46908
5dbf00e8-a179-4bd7-933c-ef55957828da
Item type 学術雑誌論文 / Journal Article(1)
公開日 2014-11-07
タイトル
タイトル Measuring the vascular diameter of brain surface and parenchymal arteries in awake mouse.
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Sekiguchi, Yuta

× Sekiguchi, Yuta

WEKO 468094

Sekiguchi, Yuta

Search repository
Masamoto, Kazuto

× Masamoto, Kazuto

WEKO 468095

Masamoto, Kazuto

Search repository
Takuwa, Hiroyuki

× Takuwa, Hiroyuki

WEKO 468096

Takuwa, Hiroyuki

Search repository
Kawaguchi, Hiroshi

× Kawaguchi, Hiroshi

WEKO 468097

Kawaguchi, Hiroshi

Search repository
Kanno, Iwao

× Kanno, Iwao

WEKO 468098

Kanno, Iwao

Search repository
Ito, Hiroshi

× Ito, Hiroshi

WEKO 468099

Ito, Hiroshi

Search repository
Tomita, Yutaka

× Tomita, Yutaka

WEKO 468100

Tomita, Yutaka

Search repository
Itoh, Yoshiaki

× Itoh, Yoshiaki

WEKO 468101

Itoh, Yoshiaki

Search repository
Suzuki, Norihiro

× Suzuki, Norihiro

WEKO 468102

Suzuki, Norihiro

Search repository
Sudo, Ryo

× Sudo, Ryo

WEKO 468103

Sudo, Ryo

Search repository
Tanishita, Kazuo

× Tanishita, Kazuo

WEKO 468104

Tanishita, Kazuo

Search repository
関口 優太

× 関口 優太

WEKO 468105

en 関口 優太

Search repository
正本 和人

× 正本 和人

WEKO 468106

en 正本 和人

Search repository
田桑 弘之

× 田桑 弘之

WEKO 468107

en 田桑 弘之

Search repository
川口 拓之

× 川口 拓之

WEKO 468108

en 川口 拓之

Search repository
菅野 巖

× 菅野 巖

WEKO 468109

en 菅野 巖

Search repository
伊藤 浩

× 伊藤 浩

WEKO 468110

en 伊藤 浩

Search repository
冨田 裕

× 冨田 裕

WEKO 468111

en 冨田 裕

Search repository
抄録
内容記述タイプ Abstract
内容記述 The present study reports a semiautomatic image analysis method for measuring the spatiotemporal dynamics of the vessel dilation that was fluorescently imaged with either confocal or two-photon microscope. With this method, arterial dilation induced by whisker stimulation was compared between cortical surface and parenchymal tissue in the vibrissae area of somatosensory cortex in awake Tie2-GFP mice in which the vascular endothelium had genetically expressed green fluorescent protein. We observed that a mean arterial diameter during a pre-stimulus baseline state was 39 ± 7, 19 ± 1, 16 ± 4, 17 ± 4, and 14 ± 3 μm at depths of 0, 100, 200, 300, and 400 μm, respectively. The stimulation-evoked dilation induced by mechanical whisker deflection (10 Hz for 5 s) was 3.4 ± 0.8, 1.8 ± 0.8, 1.8 ± 0.9, 1.6 ± 0.9, and 1.5 ± 0.6 μm at each depth, respectively. Consequently, no significant differences were observed for the vessel dilation rate between the cortical surface and parenchymal arteries: 8.8 %, 9.9 %, 10.9 %, 9.2 %, and 10.3 % relative to their baseline diameters, respectively. These preliminary results demonstrate that the present method is useful to further investigate the quantitative relationships between the spatiotemporally varying arterial tone and the associated blood flow changes in the parenchymal microcirculation to reveal the regulatory mechanism of the cerebral blood flow.
書誌情報 Oxygen Transport to Tissue XXXV (Advances in Experimental Medicine and Biology ; v.789)

巻 789, p. 419-425, 発行日 2013-07
出版者
出版者 Springer
ISSN
収録物識別子タイプ ISSN
収録物識別子 0065-2598
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:46:11.083529
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3