Relative biological effectiveness of therapeutic proton beams for HSG cells at Japanese proton therapy facilities

https://repo.qst.go.jp/records/46806
https://repo.qst.go.jp/records/46806
2f4c7ba1-5454-440c-8127-0ef086bc2778
Item type 学術雑誌論文 / Journal Article(1)
公開日 2014-08-20
タイトル
タイトル Relative biological effectiveness of therapeutic proton beams for HSG cells at Japanese proton therapy facilities
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Aoki, Mizuho

× Aoki, Mizuho

WEKO 466880

Aoki, Mizuho

Search repository
Furusawa, Yoshiya

× Furusawa, Yoshiya

WEKO 466881

Furusawa, Yoshiya

Search repository
Uzawa, Akiko

× Uzawa, Akiko

WEKO 466882

Uzawa, Akiko

Search repository
Matsumoto, Yoshitaka

× Matsumoto, Yoshitaka

WEKO 466883

Matsumoto, Yoshitaka

Search repository
Hirayama, Ryoichi

× Hirayama, Ryoichi

WEKO 466884

Hirayama, Ryoichi

Search repository
Tsuruoka, Chizuru

× Tsuruoka, Chizuru

WEKO 466885

Tsuruoka, Chizuru

Search repository
et.al

× et.al

WEKO 466886

et.al

Search repository
青木 瑞穂

× 青木 瑞穂

WEKO 466887

en 青木 瑞穂

Search repository
古澤 佳也

× 古澤 佳也

WEKO 466888

en 古澤 佳也

Search repository
鵜澤 玲子

× 鵜澤 玲子

WEKO 466889

en 鵜澤 玲子

Search repository
松本 孔貴

× 松本 孔貴

WEKO 466890

en 松本 孔貴

Search repository
平山 亮一

× 平山 亮一

WEKO 466891

en 平山 亮一

Search repository
鶴岡 千鶴

× 鶴岡 千鶴

WEKO 466892

en 鶴岡 千鶴

Search repository
抄録
内容記述タイプ Abstract
内容記述 We investigated the relative biological effectiveness (RBE) of therapeutic proton beams at six proton facilities in Japan with respect to cell lethality of HSG cells. The RBE of treatments could be determined from experimental data. For this purpose, we used a cell survival assay to compare the cell-killing efficiency of proton beams. Among the five linear accelerator (LINAC) X-ray machines at 4 or 6 MeV that were used as reference beams, there was only a small variation (coefficient of variation CV = 3.1% at D10) in biological effectiveness. The averaged value of D10 for the proton beams at the middle position of the spread-out Bragg peak (SOBP) was 4.98. These values showed good agreement, with a CV of 4.3% among the facilities. Thus, the average RBE10 (RBE at the D10 level) at the middle position of the SOBP beam for six facilities in Japan was 1.05 with a CV of 2.8%.
書誌情報 Journal of Radiation Research

巻 55, 号 4, p. 812-815, 発行日 2014-04
出版者
出版者 Oxford Univ Press
ISSN
収録物識別子タイプ ISSN
収録物識別子 0449-3060
PubMed番号
識別子タイプ PMID
関連識別子 24699001
DOI
識別子タイプ DOI
関連識別子 10.1093/jrr/rru003
関連サイト
識別子タイプ URI
関連識別子 http://jrr.oxfordjournals.org/content/55/4/812.abstract
関連名称 http://jrr.oxfordjournals.org/content/55/4/812.abstract
戻る
0
views
See details
Views