抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Introduction: When using metabolic trapping type tracers, the tracers are not always trapped in the target tissue; i.e., some are completely trapped in the target, but others can be eliminated from the target tissue at a measurable rate. The tracers that can be eliminated are termed incomplete trapping irreversible tracers. These incomplete trapping irreversible tracers may be clinically useful when the tracer beta-value, the ratio of the tracer (metabolite) elimination rate to the tracer efflux rate, is under approximately 0.1. In this study, we propose a non-input analysis for incomplete trapping irreversible tracers based on the shape analysis (Shape), a non-input analysis used for irreversible tracers. Methods: A Monte Carlo simulation study based on experimental monkey data with two actual PET tracers (a complete trapping irreversible tracer [11C]MP4A and an incomplete trapping irreversible tracer [18 F]FEP- 4MA) was performed to examine the effects of the environmental error and the tracer elimination rate on the estimation of the k3-parameter (corresponds to metabolic rate) using Shape (original) and modified Shape (M-Shape) analysis. The simulation results were also compared with the experimental results obtained with the two PET tracers. Results: When the tracer beta-value was over 0.03, the M-Shape method was superior to the Shape method for the estimation of the k3-parameter. The simulation results were also in reasonable agreement with the experimental ones. Conclusions: M-Shape can be used as the non-input analysis of incomplete trapping irreversible tracers for PET study. |
|||||
書誌情報 |
Nuclear Medicine and Biology 巻 40, 号 5, p. 664-669, 発行日 2012-02 |
|||||