The dosimetric impact of respiratory breast movement and daily setup error on tangential whole breast irradiation using conventional wedge, field-in-field and irregular surface compensator techniques

https://repo.qst.go.jp/records/46509
https://repo.qst.go.jp/records/46509
3f8cdaee-7f47-47cb-8f75-e846090f6eeb
Item type 学術雑誌論文 / Journal Article(1)
公開日 2013-03-28
タイトル
タイトル The dosimetric impact of respiratory breast movement and daily setup error on tangential whole breast irradiation using conventional wedge, field-in-field and irregular surface compensator techniques
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Furuya, Tomohisa

× Furuya, Tomohisa

WEKO 463472

Furuya, Tomohisa

Search repository
Sugimoto, Satoru

× Sugimoto, Satoru

WEKO 463473

Sugimoto, Satoru

Search repository
Kurokawa, Chie

× Kurokawa, Chie

WEKO 463474

Kurokawa, Chie

Search repository
Ozawa, Shuichi

× Ozawa, Shuichi

WEKO 463475

Ozawa, Shuichi

Search repository
Karasawa, Kumiko

× Karasawa, Kumiko

WEKO 463476

Karasawa, Kumiko

Search repository
Sasai, Keisuke

× Sasai, Keisuke

WEKO 463477

Sasai, Keisuke

Search repository
唐澤 久美子

× 唐澤 久美子

WEKO 463478

en 唐澤 久美子

Search repository
笹井 啓資

× 笹井 啓資

WEKO 463479

en 笹井 啓資

Search repository
抄録
内容記述タイプ Abstract
内容記述 To evaluate the dosimetric impact of respiratory breast motion and daily setup error on whole breast irradi-ation (WBI) using three irradiation techniques; conventional wedge (CW), field-in-field (FIF) and irregularsurface compensator (ISC). WBI was planned for 16 breast cancer patients. The dose indices for evaluated clinical target volume (CTVevl), lung, and body were evaluated. For the anterior-posterior (AP) respiratorymotion and setup error of a single fraction, the isocenter was moved according to a sine function, and thedose indices were averaged over one period. Furthermore, the dose indices were weighted according tosetup error frequencies that have a normal distribution to model systematic and random setup error for the entire treatment course. In all irradiation techniques, AP movement has a significant impact on dose distri-bution. CTVevlD95(the minimum relative dose that covers 95 % volume) and V95
(the relative volume re-ceiving 95 % of the prescribed dose) were observed to significantly decrease from the original ISC plan when simulated for the entire treatment course. In contrast, the D95,V95 and dose homogeneity index did not significantly differ from those of the original plans for FIF and CW. With regard to lung dose, the effect of motion was very similar among all three techniques. The dosimetric impact of AP respiratory breast motion and setup error was largest for the ISC technique, and the second greatest effect was observed with the FIF technique. However, these variations are relatively small.
書誌情報 Journal of Radiation Research

巻 54, p. 157-165, 発行日 2012-08
ISSN
収録物識別子タイプ ISSN
収録物識別子 0449-3060
DOI
識別子タイプ DOI
関連識別子 10.1093/jrr/rrs064
戻る
0
views
See details
Views