ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Approach to 3D dose verification by utilizing autoactivation

https://repo.qst.go.jp/records/46491
https://repo.qst.go.jp/records/46491
22b5924f-2c53-499c-b762-cf7c1ac90d0b
Item type 学術雑誌論文 / Journal Article(1)
公開日 2013-02-14
タイトル
タイトル Approach to 3D dose verification by utilizing autoactivation
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Nakajima, Yasunori

× Nakajima, Yasunori

WEKO 463261

Nakajima, Yasunori

Search repository
Kohno, Toshiyuki

× Kohno, Toshiyuki

WEKO 463262

Kohno, Toshiyuki

Search repository
Inaniwa, Taku

× Inaniwa, Taku

WEKO 463263

Inaniwa, Taku

Search repository
Satou, Shinji

× Satou, Shinji

WEKO 463264

Satou, Shinji

Search repository
Yoshida, Eiji

× Yoshida, Eiji

WEKO 463265

Yoshida, Eiji

Search repository
Yamaya, Taiga

× Yamaya, Taiga

WEKO 463266

Yamaya, Taiga

Search repository
et.al

× et.al

WEKO 463267

et.al

Search repository
中島 靖紀

× 中島 靖紀

WEKO 463268

en 中島 靖紀

Search repository
河野 俊之

× 河野 俊之

WEKO 463269

en 河野 俊之

Search repository
稲庭 拓

× 稲庭 拓

WEKO 463270

en 稲庭 拓

Search repository
佐藤 眞二

× 佐藤 眞二

WEKO 463271

en 佐藤 眞二

Search repository
吉田 英治

× 吉田 英治

WEKO 463272

en 吉田 英治

Search repository
山谷 泰賀

× 山谷 泰賀

WEKO 463273

en 山谷 泰賀

Search repository
抄録
内容記述タイプ Abstract
内容記述 To evaluate the deposited dose distribution in a target, we have proposed to utilize the annihilation gamma-rays emitted from the positron emitters distributed in the target irradiated with stable heavy-ion beams. Verification of the one dimensional (1-D) dose distributions along and perpendicular to a beam axis was achieved through our previous works. The purpose of this work is to verify 3-D dose distributions. As the first attempt uniform PMMA targets were irradiated in simple rectangular parallelepiped shapes, and the annihilation gamma-rays were detected with a PET scanner. By comparing the detected annihilation gamma-ray distributions with the calculated ones the dose distributions were estimated. As a result the estimated positions of the distal edges of the dose distributions were in agreement with the measured ones within 1 mm. However, the estimated positions of the proximal edges were different from the measured ones by 5–9 mm depending on the thickness of the irradiation filed
書誌情報 Nuclear Instruments & Methods in Physics Research Section A

巻 648, 号 Suppl.1, p. S119-S121, 発行日 2010-12
ISSN
収録物識別子タイプ ISSN
収録物識別子 0168-9002
DOI
識別子タイプ DOI
関連識別子 10.1016/j.nima.2010.12.078
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:51:09.896453
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3