{"created":"2023-05-15T14:36:07.117675+00:00","id":46491,"links":{},"metadata":{"_buckets":{"deposit":"b6a2fc76-49a4-4f69-8453-a90ad972671f"},"_deposit":{"created_by":1,"id":"46491","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"46491"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00046491","sets":["1"]},"author_link":["463271","463266","463273","463267","463262","463272","463269","463270","463268","463265","463261","463263","463264"],"item_8_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2010-12","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"Suppl.1","bibliographicPageEnd":"S121","bibliographicPageStart":"S119","bibliographicVolumeNumber":"648","bibliographic_titles":[{"bibliographic_title":"Nuclear Instruments & Methods in Physics Research Section A"}]}]},"item_8_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"To evaluate the deposited dose distribution in a target, we have proposed to utilize the annihilation gamma-rays emitted from the positron emitters distributed in the target irradiated with stable heavy-ion beams. Verification of the one dimensional (1-D) dose distributions along and perpendicular to a beam axis was achieved through our previous works. The purpose of this work is to verify 3-D dose distributions. As the first attempt uniform PMMA targets were irradiated in simple rectangular parallelepiped shapes, and the annihilation gamma-rays were detected with a PET scanner. By comparing the detected annihilation gamma-ray distributions with the calculated ones the dose distributions were estimated. As a result the estimated positions of the distal edges of the dose distributions were in agreement with the measured ones within 1 mm. However, the estimated positions of the proximal edges were different from the measured ones by 5–9 mm depending on the thickness of the irradiation filed","subitem_description_type":"Abstract"}]},"item_8_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1016/j.nima.2010.12.078","subitem_relation_type_select":"DOI"}}]},"item_8_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0168-9002","subitem_source_identifier_type":"ISSN"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Nakajima, Yasunori"}],"nameIdentifiers":[{"nameIdentifier":"463261","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kohno, Toshiyuki"}],"nameIdentifiers":[{"nameIdentifier":"463262","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Inaniwa, Taku"}],"nameIdentifiers":[{"nameIdentifier":"463263","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Satou, Shinji"}],"nameIdentifiers":[{"nameIdentifier":"463264","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Yoshida, Eiji"}],"nameIdentifiers":[{"nameIdentifier":"463265","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Yamaya, Taiga"}],"nameIdentifiers":[{"nameIdentifier":"463266","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"et.al"}],"nameIdentifiers":[{"nameIdentifier":"463267","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"中島 靖紀","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"463268","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"河野 俊之","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"463269","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"稲庭 拓","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"463270","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"佐藤 眞二","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"463271","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"吉田 英治","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"463272","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"山谷 泰賀","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"463273","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Approach to 3D dose verification by utilizing autoactivation","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Approach to 3D dose verification by utilizing autoactivation"}]},"item_type_id":"8","owner":"1","path":["1"],"pubdate":{"attribute_name":"公開日","attribute_value":"2013-02-14"},"publish_date":"2013-02-14","publish_status":"0","recid":"46491","relation_version_is_last":true,"title":["Approach to 3D dose verification by utilizing autoactivation"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T23:51:09.768995+00:00"}