WEKO3
アイテム
ANALYSIS OF CELL-SURVIVAL FRACTIONS FOR HEAVY-ION IRRADIATIONS BASED ON MICRODOSIMETRIC KINETIC MODEL IMPLEMENTED IN THE PARTICLE AND HEAVY ION TRANSPORT CODE SYSTEM
https://repo.qst.go.jp/records/46179
https://repo.qst.go.jp/records/4617993841fa8-b37f-402a-9d81-ba7b64a294b9
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2011-10-07 | |||||
タイトル | ||||||
タイトル | ANALYSIS OF CELL-SURVIVAL FRACTIONS FOR HEAVY-ION IRRADIATIONS BASED ON MICRODOSIMETRIC KINETIC MODEL IMPLEMENTED IN THE PARTICLE AND HEAVY ION TRANSPORT CODE SYSTEM | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Sato, Tatsuhiko
× Sato, Tatsuhiko× Watanabe, Ritsuko× Kase, Yuki× Tsuruoka, Chizuru× Suzuki, Masao× Furusawa, Yoshiya× Niita, Koji× 鶴岡 千鶴× 鈴木 雅雄× 古澤 佳也 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | It is considered that the linear energy transfer (LET) may not be the ideal index for expressing the relative biological effective- ness (RBE) of cell killing for heavy-ion irradiation, as the ion-species dependencies have clearly been observed in the relation between LET and RBE derived from cell-survival fraction data. The previously measured survival fractions of four cell lines irra- diated by various ion species, employing the saturation-corrected dose-mean lineal energy, y*, instead of LET as the index of the RBE were therefore re-analysed. In the analysis, the initial slopes of the survival fractions, the so-called a-parameter in the linear-quadratic model, were plotted as a function of y*, which was calculated by the microdosimetric kinetic (MK) model implemented in the Particle and Heavy Ion Transport code System. It was found from the analysis that the ion-species depen- dencies observed in the relations between a and LET disappeared from those between a and y*, and their relations can be well reproduced by a simple equation derived from the MK model. These results clearly indicate the suitability of y* to be used in the estimation of the RBE of cell killing for heavy-ion irradiations, which is of great importance in the treatment planning of charged-particle therapy. | |||||
書誌情報 |
Radiation Protection Dosimetry 巻 143, 号 2/4, p. 491-496, 発行日 2010-12 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0144-8420 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1093/rpd/ncq484 |