  1. 原著論文

Biological effects of low-dose ionizing radiation exposure on interventional cardiologists

https://repo.qst.go.jp/records/45899
https://repo.qst.go.jp/records/45899
2f459de3-3bd6-4d92-9257-67007216aaa5
Item type 学術雑誌論文 / Journal Article(1)
公開日 2010-09-28
タイトル
タイトル Biological effects of low-dose ionizing radiation exposure on interventional cardiologists
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Zakeri, Farideh

× Zakeri, Farideh

WEKO 456603

Zakeri, Farideh

Search repository
Hirobe, Tomohisa

× Hirobe, Tomohisa

WEKO 456604

Hirobe, Tomohisa

Search repository
Akbari, Noghabi Kambiz

× Akbari, Noghabi Kambiz

WEKO 456605

Akbari, Noghabi Kambiz

Search repository
廣部 知久

× 廣部 知久

WEKO 456606

en 廣部 知久

Search repository
抄録
内容記述タイプ Abstract
内容記述 Background Interventional cardiologists (ICs) are likely to receive high radiation exposure as a result of procedures they undertake.
Aims To assess the effects of low-dose X-ray radiation exposure on chromosomal damage and on selected
indices of cellular and humoral immunity in ICs.
Methods The study population consisted of 37 ICs and 37 clinical physicians as the control group with similar
age, sex and duration of employment, without any work-related exposure to ionizing radiation. Cytogenetic
studies were performed by chromosome aberration analysis and immunological studies by
flow cytometry, enzyme-linked immunosorbent assay and immunodiffusion techniques.
Results The frequencies of aberrant cells, chromosome breaks and dicentrics plus centric rings were significantly higher in the exposed group compared to the control group (P , 0.05; P , 0.01; P , 0.001,
respectively), without positive correlation between the frequency of dicentric and centric ring aberrations
and the cumulative doses of the ICs (r 5 0.24, not significant). A significant increase was observed
in the expression of activation marker CD69 on TCD41 stimulated cells in serum immunoglobulin G and interleukin (IL)-2 (P , 0.05) and a significant decrease in serum IL-10 (P , 0.05) in the ICs compared with that of the control group. There was no statistical difference between the two groups in terms of number of white blood cells and lymphocytes, CD31, CD41 and CD81 T cells, CD191 and CD161 561 cells and concentrations of interferon (IFN)-g, IL-4, IL-6 and IL-8 cytokines.
Conclusions While cytogenetic results show higher chromosomal damage, some immune responses are stimulated or modulated immunologically in ICs.
書誌情報 Occupational Medicine

巻 60, 号 6, p. 464-469, 発行日 2010-06
ISSN
収録物識別子タイプ ISSN
収録物識別子 0962-7480
DOI
識別子タイプ DOI
関連識別子 10.1093/occmed/kqq062
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:58:16.199537
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3