ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Assessment of the homogeneous efficacy of carbon ions in the spread-out Bragg peak for human lung cancer cell lines

https://repo.qst.go.jp/records/45880
https://repo.qst.go.jp/records/45880
103ada01-a750-4a16-9e80-92b7ea6dac1d
Item type 学術雑誌論文 / Journal Article(1)
公開日 2010-08-13
タイトル
タイトル Assessment of the homogeneous efficacy of carbon ions in the spread-out Bragg peak for human lung cancer cell lines
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Takiguchi, Yasuo

× Takiguchi, Yasuo

WEKO 456352

Takiguchi, Yasuo

Search repository
Miyamoto, Tadaaki

× Miyamoto, Tadaaki

WEKO 456353

Miyamoto, Tadaaki

Search repository
Nagao, Keiichi

× Nagao, Keiichi

WEKO 456354

Nagao, Keiichi

Search repository
Kuriyama, Takayuki

× Kuriyama, Takayuki

WEKO 456355

Kuriyama, Takayuki

Search repository
宮本 忠昭

× 宮本 忠昭

WEKO 456356

en 宮本 忠昭

Search repository
抄録
内容記述タイプ Abstract
内容記述 PURPOSE: The aim of this study was to assess the radiosensitivities and homogeneous efficacy in the spread-out Bragg peak (SOBP) for lung cancer cell lines exposed to carbon ions. MATERIALS AND METHODS: The dose-dependent survival rates of seven cell lines exposed to carbon ions, fast neutrons, and photons were obtained using colony-forming assays in vitro. The relative biological effectiveness (RBE) of carbon ions and fast neutrons to photons was determined by comparing the doses at the 10% and 1% survival levels. RESULTS: The RBEs at 13, 40, 50, and 80 keV/microm were 1.20-1.29, 1.55-1.80, 1.57-2.00, and 1.69-2.58, respectively, at the 10% survival level. The RBE of 290 MeV carbon ions increased with increasing linear energy transfer. The biological dose (relative physical dose x RBE) distributions in the SOBP did not statistically differ at the proximal, mid, or distal points at the 10% (p = 0.945) and 1% (p = 0.211) survival levels, respectively; however, deviation of the biological dose at 10% and 1% survival were 3%-16% and 6%-24%, respectively. Furthermore, 290 MeV carbon ions at 80 keV/microm in the SOBP were nearly equivalent to 30 MeV fast neutrons. CONCLUSION: Our results demonstrate nearly homogeneous effectiveness in the SOBP, although we are aware of the deviation in some cell lines
書誌情報 Radiation Medicine

巻 25, 号 6, p. 272-277, 発行日 2007-07
ISSN
収録物識別子タイプ ISSN
収録物識別子 0288-2043
DOI
識別子タイプ DOI
関連識別子 10.1007/s11604-007-0134-6
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:58:29.444468
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3