WEKO3
アイテム
{"_buckets": {"deposit": "e3556683-509a-40d0-959a-94ef5e694946"}, "_deposit": {"created_by": 1, "id": "45880", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "45880"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00045880", "sets": ["1"]}, "author_link": ["456352", "456353", "456355", "456356", "456354"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2007-07", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "6", "bibliographicPageEnd": "277", "bibliographicPageStart": "272", "bibliographicVolumeNumber": "25", "bibliographic_titles": [{"bibliographic_title": "Radiation Medicine"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "PURPOSE: The aim of this study was to assess the radiosensitivities and homogeneous efficacy in the spread-out Bragg peak (SOBP) for lung cancer cell lines exposed to carbon ions. MATERIALS AND METHODS: The dose-dependent survival rates of seven cell lines exposed to carbon ions, fast neutrons, and photons were obtained using colony-forming assays in vitro. The relative biological effectiveness (RBE) of carbon ions and fast neutrons to photons was determined by comparing the doses at the 10% and 1% survival levels. RESULTS: The RBEs at 13, 40, 50, and 80 keV/microm were 1.20-1.29, 1.55-1.80, 1.57-2.00, and 1.69-2.58, respectively, at the 10% survival level. The RBE of 290 MeV carbon ions increased with increasing linear energy transfer. The biological dose (relative physical dose x RBE) distributions in the SOBP did not statistically differ at the proximal, mid, or distal points at the 10% (p = 0.945) and 1% (p = 0.211) survival levels, respectively; however, deviation of the biological dose at 10% and 1% survival were 3%-16% and 6%-24%, respectively. Furthermore, 290 MeV carbon ions at 80 keV/microm in the SOBP were nearly equivalent to 30 MeV fast neutrons. CONCLUSION: Our results demonstrate nearly homogeneous effectiveness in the SOBP, although we are aware of the deviation in some cell lines", "subitem_description_type": "Abstract"}]}, "item_8_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1007/s11604-007-0134-6", "subitem_relation_type_select": "DOI"}}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0288-2043", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Takiguchi, Yasuo"}], "nameIdentifiers": [{"nameIdentifier": "456352", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Miyamoto, Tadaaki"}], "nameIdentifiers": [{"nameIdentifier": "456353", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Nagao, Keiichi"}], "nameIdentifiers": [{"nameIdentifier": "456354", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kuriyama, Takayuki"}], "nameIdentifiers": [{"nameIdentifier": "456355", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "宮本 忠昭", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "456356", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Assessment of the homogeneous efficacy of carbon ions in the spread-out Bragg peak for human lung cancer cell lines", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Assessment of the homogeneous efficacy of carbon ions in the spread-out Bragg peak for human lung cancer cell lines"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/45880", "pubdate": {"attribute_name": "公開日", "attribute_value": "2010-08-13"}, "publish_date": "2010-08-13", "publish_status": "0", "recid": "45880", "relation": {}, "relation_version_is_last": true, "title": ["Assessment of the homogeneous efficacy of carbon ions in the spread-out Bragg peak for human lung cancer cell lines"], "weko_shared_id": -1}
Assessment of the homogeneous efficacy of carbon ions in the spread-out Bragg peak for human lung cancer cell lines
https://repo.qst.go.jp/records/45880
https://repo.qst.go.jp/records/45880103ada01-a750-4a16-9e80-92b7ea6dac1d
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2010-08-13 | |||||
タイトル | ||||||
タイトル | Assessment of the homogeneous efficacy of carbon ions in the spread-out Bragg peak for human lung cancer cell lines | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Takiguchi, Yasuo
× Takiguchi, Yasuo× Miyamoto, Tadaaki× Nagao, Keiichi× Kuriyama, Takayuki× 宮本 忠昭 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | PURPOSE: The aim of this study was to assess the radiosensitivities and homogeneous efficacy in the spread-out Bragg peak (SOBP) for lung cancer cell lines exposed to carbon ions. MATERIALS AND METHODS: The dose-dependent survival rates of seven cell lines exposed to carbon ions, fast neutrons, and photons were obtained using colony-forming assays in vitro. The relative biological effectiveness (RBE) of carbon ions and fast neutrons to photons was determined by comparing the doses at the 10% and 1% survival levels. RESULTS: The RBEs at 13, 40, 50, and 80 keV/microm were 1.20-1.29, 1.55-1.80, 1.57-2.00, and 1.69-2.58, respectively, at the 10% survival level. The RBE of 290 MeV carbon ions increased with increasing linear energy transfer. The biological dose (relative physical dose x RBE) distributions in the SOBP did not statistically differ at the proximal, mid, or distal points at the 10% (p = 0.945) and 1% (p = 0.211) survival levels, respectively; however, deviation of the biological dose at 10% and 1% survival were 3%-16% and 6%-24%, respectively. Furthermore, 290 MeV carbon ions at 80 keV/microm in the SOBP were nearly equivalent to 30 MeV fast neutrons. CONCLUSION: Our results demonstrate nearly homogeneous effectiveness in the SOBP, although we are aware of the deviation in some cell lines | |||||
書誌情報 |
Radiation Medicine 巻 25, 号 6, p. 272-277, 発行日 2007-07 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0288-2043 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1007/s11604-007-0134-6 |