  1. 原著論文

Development of a high dynamic range read-out system using multiple photodiodes for the total absorption calorimeter of the CALorimetric Electron Telescope

https://repo.qst.go.jp/records/45490
https://repo.qst.go.jp/records/45490
cbacc418-38f2-49f5-bcb0-205e811686b9
Item type 学術雑誌論文 / Journal Article(1)
公開日 2009-04-17
タイトル
タイトル Development of a high dynamic range read-out system using multiple photodiodes for the total absorption calorimeter of the CALorimetric Electron Telescope
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Katayose, Yusaku

× Katayose, Yusaku

WEKO 451972

Katayose, Yusaku

Search repository
Shibata, M

× Shibata, M

WEKO 451973

Shibata, M

Search repository
Torii, Syoji

× Torii, Syoji

WEKO 451974

Torii, Syoji

Search repository
Shimizu, Y

× Shimizu, Y

WEKO 451975

Shimizu, Y

Search repository
Tamura, Tadahisa

× Tamura, Tadahisa

WEKO 451976

Tamura, Tadahisa

Search repository
Hibino, Kinya

× Hibino, Kinya

WEKO 451977

Hibino, Kinya

Search repository
Okuno, Syouji

× Okuno, Syouji

WEKO 451978

Okuno, Syouji

Search repository
Yoshida, Kenji

× Yoshida, Kenji

WEKO 451979

Yoshida, Kenji

Search repository
Kitamura, Hisashi

× Kitamura, Hisashi

WEKO 451980

Kitamura, Hisashi

Search repository
Uchihori, Yukio

× Uchihori, Yukio

WEKO 451981

Uchihori, Yukio

Search repository
Murakami, Hiroyuki

× Murakami, Hiroyuki

WEKO 451982

Murakami, Hiroyuki

Search repository
Kubo, Shin

× Kubo, Shin

WEKO 451983

Kubo, Shin

Search repository
北村 尚

× 北村 尚

WEKO 451984

en 北村 尚

Search repository
内堀 幸夫

× 内堀 幸夫

WEKO 451985

en 内堀 幸夫

Search repository
抄録
内容記述タイプ Abstract
内容記述 Read-out systems using Si-PIN photodiodes and front-end circuits(FEC) were studied to measure the energy deposit with a dynamic range from 1MIP(Minimum Ionization Particle) to 106 MIPs in a BGO bar of the total absorption calorimeter (TASC) of the CALET (CALorimetric Electron Telescope) instrument. Three types of FEC were tested for the photodiode read out. Two were A225(AMP-TEK), which consists of a hybrid charge sensitive preamplifier and a shaping amplifier, and MPX-08 (NOVA), which is a charge-integrating chip. It was confirmed that the A225 has a resolution of about 0.31 fC and a maximum range of about 2 pC. It was found that the use of the A225 makes a wide range measurement with six orders of magnitude possible using three photodiodes. A new hybrid integrated circuit is being developed to measure a BGO signal with a dynamic range of seven orders using two photodiodes. This FEC consists of two preamplifiers, one for a smaller photodiode and one for a larger one. A high-gain preamplifier was developed and its performance was evaluated. The resolution is about 0.5 fC and the maximum range is more than 25 pC. This makes a dynamic range with four orders of magnitude possible using one photodiode. The outline of a read-out systems using each type of FEC and the state of the development of each system is described below.
書誌情報 Journal of the Physical Society of Japan

巻 78, 号 Suppl. A, p. 177-180, 発行日 2009-04
ISSN
収録物識別子タイプ ISSN
収録物識別子 0031-9015
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-16 00:03:08.203720
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3