{"created":"2023-05-15T14:35:18.751977+00:00","id":45490,"links":{},"metadata":{"_buckets":{"deposit":"b4bf12f0-6ad1-4663-aafd-edd0bb84e290"},"_deposit":{"created_by":1,"id":"45490","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"45490"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00045490","sets":["1"]},"author_link":["451974","451980","451985","451972","451979","451976","451978","451982","451981","451984","451973","451975","451983","451977"],"item_8_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2009-04","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"Suppl. A","bibliographicPageEnd":"180","bibliographicPageStart":"177","bibliographicVolumeNumber":"78","bibliographic_titles":[{"bibliographic_title":"Journal of the Physical Society of Japan"}]}]},"item_8_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Read-out systems using Si-PIN photodiodes and front-end circuits(FEC) were studied to measure the energy deposit with a dynamic range from 1MIP(Minimum Ionization Particle) to 106 MIPs in a BGO bar of the total absorption calorimeter (TASC) of the CALET (CALorimetric Electron Telescope) instrument. Three types of FEC were tested for the photodiode read out. Two were A225(AMP-TEK), which consists of a hybrid charge sensitive preamplifier and a shaping amplifier, and MPX-08 (NOVA), which is a charge-integrating chip. It was confirmed that the A225 has a resolution of about 0.31 fC and a maximum range of about 2 pC. It was found that the use of the A225 makes a wide range measurement with six orders of magnitude possible using three photodiodes. A new hybrid integrated circuit is being developed to measure a BGO signal with a dynamic range of seven orders using two photodiodes. This FEC consists of two preamplifiers, one for a smaller photodiode and one for a larger one. A high-gain preamplifier was developed and its performance was evaluated. The resolution is about 0.5 fC and the maximum range is more than 25 pC. This makes a dynamic range with four orders of magnitude possible using one photodiode. The outline of a read-out systems using each type of FEC and the state of the development of each system is described below.","subitem_description_type":"Abstract"}]},"item_8_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0031-9015","subitem_source_identifier_type":"ISSN"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Katayose, Yusaku"}],"nameIdentifiers":[{"nameIdentifier":"451972","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Shibata, M"}],"nameIdentifiers":[{"nameIdentifier":"451973","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Torii, Syoji"}],"nameIdentifiers":[{"nameIdentifier":"451974","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Shimizu, Y"}],"nameIdentifiers":[{"nameIdentifier":"451975","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Tamura, Tadahisa"}],"nameIdentifiers":[{"nameIdentifier":"451976","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Hibino, Kinya"}],"nameIdentifiers":[{"nameIdentifier":"451977","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Okuno, Syouji"}],"nameIdentifiers":[{"nameIdentifier":"451978","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Yoshida, Kenji"}],"nameIdentifiers":[{"nameIdentifier":"451979","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kitamura, Hisashi"}],"nameIdentifiers":[{"nameIdentifier":"451980","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Uchihori, Yukio"}],"nameIdentifiers":[{"nameIdentifier":"451981","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Murakami, Hiroyuki"}],"nameIdentifiers":[{"nameIdentifier":"451982","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kubo, Shin"}],"nameIdentifiers":[{"nameIdentifier":"451983","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"北村 尚","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"451984","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"内堀 幸夫","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"451985","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Development of a high dynamic range read-out system using multiple photodiodes for the total absorption calorimeter of the CALorimetric Electron Telescope","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Development of a high dynamic range read-out system using multiple photodiodes for the total absorption calorimeter of the CALorimetric Electron Telescope"}]},"item_type_id":"8","owner":"1","path":["1"],"pubdate":{"attribute_name":"公開日","attribute_value":"2009-04-17"},"publish_date":"2009-04-17","publish_status":"0","recid":"45490","relation_version_is_last":true,"title":["Development of a high dynamic range read-out system using multiple photodiodes for the total absorption calorimeter of the CALorimetric Electron Telescope"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-16T00:03:08.098916+00:00"}