WEKO3
アイテム
{"_buckets": {"deposit": "1590fe5b-27b9-46e6-874c-d382278330ed"}, "_deposit": {"created_by": 1, "id": "45454", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "45454"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00045454", "sets": ["1"]}, "author_link": ["451625", "451616", "451609", "451617", "451621", "451611", "451610", "451612", "451620", "451613", "451615", "451623", "451619", "451614", "451624", "451626", "451622", "451618"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2008-12", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "2", "bibliographicPageEnd": "304", "bibliographicPageStart": "300", "bibliographicVolumeNumber": "73", "bibliographic_titles": [{"bibliographic_title": "European Journal of Radiology"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "To investigate the relationship between liver glucose, glycogen, and plasma glucose in diabetic patients, in vivo liver carbon-13 magnetic resonance spectroscopy (13C MRS) with a clinical 3.0 T MR system was performed. Subjects were healthy male volunteers (n=5) and male type-2 diabetic patients (n=5). Pre- and during oral glucose tolerance tests (OGTT), 13C MR spectra without proton decoupling were acquired in a monitoring period of over six hours, and in total seven spectra were obtained from each subject. For OGTT, 75 g of glucose, including 5 g of [1-13C]glucose, was administered. \nThe MR signals of liver [1-13C]glucose and glycogen were detected and their time-course changes were assessed in comparison with the plasma data obtained at screening. The correlations between the fasting plasma glucose level and liver glycogen/glucose rate (Spearman: p=-0.68, p\u003c0.05, n=10) and the fasting plasma glucose level and liver glycogen peak/fasting rate (Spearman: p=-0.67, p\u003c0.05, n=10) indicated that 13C MRS can perform noninvasive measurement of glycogen storage/degradation ability in the liver individually and can assist in tailor-made therapy for diabetes. \nIn conclusion, 13C MRS has a potential to become a powerful tool in diagnosing diabetes multilaterally.", "subitem_description_type": "Abstract"}]}, "item_8_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1016/j.ejrad.2008.10.019", "subitem_relation_type_select": "DOI"}}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0720-048X", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Tomiyasu, Moyoko"}], "nameIdentifiers": [{"nameIdentifier": "451609", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Obata, Takayuki"}], "nameIdentifiers": [{"nameIdentifier": "451610", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Nishi, Yukio"}], "nameIdentifiers": [{"nameIdentifier": "451611", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Nakamoto, Hiromitsu"}], "nameIdentifiers": [{"nameIdentifier": "451612", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Nonaka, Hiroi"}], "nameIdentifiers": [{"nameIdentifier": "451613", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Takayama, Yukihisa"}], "nameIdentifiers": [{"nameIdentifier": "451614", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Joonas, Autio"}], "nameIdentifiers": [{"nameIdentifier": "451615", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ikehira, Hiroo"}], "nameIdentifiers": [{"nameIdentifier": "451616", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kanno, Iwao"}], "nameIdentifiers": [{"nameIdentifier": "451617", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "富安 もよこ", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "451618", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "小畠 隆行", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "451619", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "西 幸雄", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "451620", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "中本 泰充", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "451621", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "野中 博意", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "451622", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "高山 幸久", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "451623", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "ヨーナス オーティオ", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "451624", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "池平 博夫", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "451625", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "菅野 巖", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "451626", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Monitoring of liver glycogen synthesis in diabetic patients using carbon-13 MR spectroscopy", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Monitoring of liver glycogen synthesis in diabetic patients using carbon-13 MR spectroscopy"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/45454", "pubdate": {"attribute_name": "公開日", "attribute_value": "2009-03-26"}, "publish_date": "2009-03-26", "publish_status": "0", "recid": "45454", "relation": {}, "relation_version_is_last": true, "title": ["Monitoring of liver glycogen synthesis in diabetic patients using carbon-13 MR spectroscopy"], "weko_shared_id": -1}
Monitoring of liver glycogen synthesis in diabetic patients using carbon-13 MR spectroscopy
https://repo.qst.go.jp/records/45454
https://repo.qst.go.jp/records/4545440f72765-321e-44ac-b32f-59f8d00edda4
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2009-03-26 | |||||
タイトル | ||||||
タイトル | Monitoring of liver glycogen synthesis in diabetic patients using carbon-13 MR spectroscopy | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Tomiyasu, Moyoko
× Tomiyasu, Moyoko× Obata, Takayuki× Nishi, Yukio× Nakamoto, Hiromitsu× Nonaka, Hiroi× Takayama, Yukihisa× Joonas, Autio× Ikehira, Hiroo× Kanno, Iwao× 富安 もよこ× 小畠 隆行× 西 幸雄× 中本 泰充× 野中 博意× 高山 幸久× ヨーナス オーティオ× 池平 博夫× 菅野 巖 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | To investigate the relationship between liver glucose, glycogen, and plasma glucose in diabetic patients, in vivo liver carbon-13 magnetic resonance spectroscopy (13C MRS) with a clinical 3.0 T MR system was performed. Subjects were healthy male volunteers (n=5) and male type-2 diabetic patients (n=5). Pre- and during oral glucose tolerance tests (OGTT), 13C MR spectra without proton decoupling were acquired in a monitoring period of over six hours, and in total seven spectra were obtained from each subject. For OGTT, 75 g of glucose, including 5 g of [1-13C]glucose, was administered. The MR signals of liver [1-13C]glucose and glycogen were detected and their time-course changes were assessed in comparison with the plasma data obtained at screening. The correlations between the fasting plasma glucose level and liver glycogen/glucose rate (Spearman: p=-0.68, p<0.05, n=10) and the fasting plasma glucose level and liver glycogen peak/fasting rate (Spearman: p=-0.67, p<0.05, n=10) indicated that 13C MRS can perform noninvasive measurement of glycogen storage/degradation ability in the liver individually and can assist in tailor-made therapy for diabetes. In conclusion, 13C MRS has a potential to become a powerful tool in diagnosing diabetes multilaterally. |
|||||
書誌情報 |
European Journal of Radiology 巻 73, 号 2, p. 300-304, 発行日 2008-12 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0720-048X | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1016/j.ejrad.2008.10.019 |