  1. 原著論文

Interlaboratory Comparison of the Dicentric Chromosome Assay for Radiation Biodosimetry in Mass Casualty Events

https://repo.qst.go.jp/records/45407
https://repo.qst.go.jp/records/45407
af22fa94-9977-4f5f-81fd-04971b5e1154
Item type 学術雑誌論文 / Journal Article(1)
公開日 2009-01-28
タイトル
タイトル Interlaboratory Comparison of the Dicentric Chromosome Assay for Radiation Biodosimetry in Mass Casualty Events
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Wilkins, Ruth

× Wilkins, Ruth

WEKO 451041

Wilkins, Ruth

Search repository
Yoshida, Mitsuaki

× Yoshida, Mitsuaki

WEKO 451042

Yoshida, Mitsuaki

Search repository
Pataje, Prasanna

× Pataje, Prasanna

WEKO 451043

Pataje, Prasanna

Search repository
et.al

× et.al

WEKO 451044

et.al

Search repository
吉田 光明

× 吉田 光明

WEKO 451045

en 吉田 光明

Search repository
抄録
内容記述タイプ Abstract
内容記述 This interlaboratory comparison validates the dicentric
chromosome assay for assessing radiation dose in mass casualty
accidents and identifies the advantages and limitations of
an international biodosimetry network. The assay's validity
and accuracy were determined among five laboratories following
the International Organization for Standardization guidelines.
Blood samples irradiated at the Armed Forces Radiobiology
Research Institute were shipped to all laboratories,
which constructed individual radiation calibration curves and
assessed the dose to dose-blinded samples. Each laboratory
constructed a dose–effect calibration curve for the yield of
dicentrics for 60Co _ rays in the 0 to 5-Gy range, using the
maximum likelihood linear-quadratic model, Y _ c _ _D _
_D2. For all laboratories, the estimated coefficients of the fitted
curves were within the 99.7% confidence intervals (CIs),
but the observed dicentric yields differed. When each laboratory
assessed radiation doses to four dose-blinded blood
samples by comparing the observed dicentric yield with the
laboratory's own calibration curve, the estimates were accurate
in all laboratories at all doses. For all laboratories, actual
doses were within the 99.75% CI for the assessed dose. Across
the dose range, the error in the estimated doses, compared to
the physical doses, ranged from 15% underestimation to 15%
overestimation.
書誌情報 Radiation Research

巻 169, 号 5, p. 551-560, 発行日 2008-05
ISSN
収録物識別子タイプ ISSN
収録物識別子 0033-7587
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-16 00:04:05.755513
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3