ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

The difference in LET and ion species dependence for induction of initially measured and non-rejoined chromatin breaks in normal human fibroblasts.

https://repo.qst.go.jp/records/45250
https://repo.qst.go.jp/records/45250
6773af86-349f-4c8e-815d-e348a396bf17
Item type 学術雑誌論文 / Journal Article(1)
公開日 2008-08-21
タイトル
タイトル The difference in LET and ion species dependence for induction of initially measured and non-rejoined chromatin breaks in normal human fibroblasts.
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Tsuruoka, Chizuru

× Tsuruoka, Chizuru

WEKO 449492

Tsuruoka, Chizuru

Search repository
Suzuki, Masao

× Suzuki, Masao

WEKO 449493

Suzuki, Masao

Search repository
Hande, Prakash

× Hande, Prakash

WEKO 449494

Hande, Prakash

Search repository
Furusawa, Yoshiya

× Furusawa, Yoshiya

WEKO 449495

Furusawa, Yoshiya

Search repository
Anzai, Kazunori

× Anzai, Kazunori

WEKO 449496

Anzai, Kazunori

Search repository
Okayasu, Ryuichi

× Okayasu, Ryuichi

WEKO 449497

Okayasu, Ryuichi

Search repository
鶴岡 千鶴

× 鶴岡 千鶴

WEKO 449498

en 鶴岡 千鶴

Search repository
鈴木 雅雄

× 鈴木 雅雄

WEKO 449499

en 鈴木 雅雄

Search repository
Hande Prakash

× Hande Prakash

WEKO 449500

en Hande Prakash

Search repository
古澤 佳也

× 古澤 佳也

WEKO 449501

en 古澤 佳也

Search repository
安西 和紀

× 安西 和紀

WEKO 449502

en 安西 和紀

Search repository
岡安 隆一

× 岡安 隆一

WEKO 449503

en 岡安 隆一

Search repository
抄録
内容記述タイプ Abstract
内容記述 We studied the LET and ion-species dependence on the induction of chromatin breaks measured immediately after irradiation as initially measured breaks and after 24h-postirradiation incubation as non- rejoined breaks, in normal human fibroblasts with different heavy ions, such as carbon, neon, silicon and iron, generated by Heavy Ion Medical Accelerator in Chiba (HIMAC) at National Institute of Radiological Science (NIRS). Chromatin breaks were measured as an excess number of fragments of prematurely condensed chromosomes using a technique of premature chromosome condensation (PCC). The result showed that the number of excess fragments per cell per Gy for initially measured chromatin breaks was dependent on LET values in the LET ranges from 13.3 to 113.1 keV/maicrmeter, while it was not dependent on ion-species. On the other hand, the number of non-rejoined chromatin breaks detected after 24h-postirradiation incubation was clearly dependent on LETs and ion-species. These results showed that no statistical difference was observed in the cross section for initially measured breaks but statistical difference was observed in that for non-rejoined breaks among carbon, neon silicon and iron ions. This suggests that the LET dependent structure in biological effects is reflected in biological consequences of repair processes.
書誌情報 Radiation Research

巻 170, 号 2, p. 163-171, 発行日 2008-08
ISSN
収録物識別子タイプ ISSN
収録物識別子 0033-7587
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-16 00:05:58.101207
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3