Deuterium magnetic resonance imaging of rabbit eye in vivo.

https://repo.qst.go.jp/records/44401
https://repo.qst.go.jp/records/44401
53a0871a-8bb3-4c3e-ba82-9f8a55e141ff
Item type 学術雑誌論文 / Journal Article(1)
公開日 2006-07-04
タイトル
タイトル Deuterium magnetic resonance imaging of rabbit eye in vivo.
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Obata, Takayuki

× Obata, Takayuki

WEKO 441194

Obata, Takayuki

Search repository
Ikehira, Hiroo

× Ikehira, Hiroo

WEKO 441195

Ikehira, Hiroo

Search repository
Koga, Masahisa

× Koga, Masahisa

WEKO 441196

Koga, Masahisa

Search repository
Yoshida, Katsuya

× Yoshida, Katsuya

WEKO 441197

Yoshida, Katsuya

Search repository
Tateno, Yukio

× Tateno, Yukio

WEKO 441198

Tateno, Yukio

Search repository
et.al

× et.al

WEKO 441199

et.al

Search repository
小畠 隆行

× 小畠 隆行

WEKO 441200

en 小畠 隆行

Search repository
池平 博夫

× 池平 博夫

WEKO 441201

en 池平 博夫

Search repository
古賀 雅久

× 古賀 雅久

WEKO 441202

en 古賀 雅久

Search repository
吉田 勝哉

× 吉田 勝哉

WEKO 441203

en 吉田 勝哉

Search repository
舘野 之男

× 舘野 之男

WEKO 441204

en 舘野 之男

Search repository
抄録
内容記述タイプ Abstract
内容記述 We used deuterium magnetic resonance imaging (2H MRI) to visualize water movement in the rabbit eye. Dynamic 2H MRI was obtained every 3.5 min at 2 tesla by FLASH pulse sequence (TR, 300 ms; TE, 10 ms; alpha = 90 degrees) with a slice thickness of 10 mm using a surface coil (4 cm in diameter). After topical administration (0.2 ml D2O), only the aqueous chamber was imaged, and the signals decreased mono-exponentially. The flow rate was 0.113/min, in agreement with that already reported. After intravenous administration of deuterated saline (3 ml/kg), the aqueous chamber became visible first during imaging, then by the vitreous body. The signals around the lens were only faintly detected. Thus, deuterium MRI was determined to be useful for visualizing water movement in the eye.
書誌情報 Magnetic Resonance in Medicine

巻 33, 号 4, p. 569-572, 発行日 1995-04
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-16 00:15:53.503069
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3