ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

In Vitro and in Vivo Comparison of Binding of 99m-Tc-labeled Anti-CEA MAb F33-104 with 99m-Tc-labeled Anti-CEA MAb BW431/26

https://repo.qst.go.jp/records/44086
https://repo.qst.go.jp/records/44086
c3ae09df-2fcf-4ca1-9e5d-f47e39e58a4f
Item type 学術雑誌論文 / Journal Article(1)
公開日 2006-05-22
タイトル
タイトル In Vitro and in Vivo Comparison of Binding of 99m-Tc-labeled Anti-CEA MAb F33-104 with 99m-Tc-labeled Anti-CEA MAb BW431/26
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Watanabe, Naoyuki

× Watanabe, Naoyuki

WEKO 438259

Watanabe, Naoyuki

Search repository
Oriuchi, Noboru

× Oriuchi, Noboru

WEKO 438260

Oriuchi, Noboru

Search repository
Tanada, Shuji

× Tanada, Shuji

WEKO 438261

Tanada, Shuji

Search repository
Murata, Hajime

× Murata, Hajime

WEKO 438262

Murata, Hajime

Search repository
Inoue, Tomio

× Inoue, Tomio

WEKO 438263

Inoue, Tomio

Search repository
Sasaki, Yasuhito

× Sasaki, Yasuhito

WEKO 438264

Sasaki, Yasuhito

Search repository
et.al

× et.al

WEKO 438265

et.al

Search repository
渡辺 直行

× 渡辺 直行

WEKO 438266

en 渡辺 直行

Search repository
棚田 修二

× 棚田 修二

WEKO 438267

en 棚田 修二

Search repository
村田 啓

× 村田 啓

WEKO 438268

en 村田 啓

Search repository
井上 登美夫

× 井上 登美夫

WEKO 438269

en 井上 登美夫

Search repository
佐々木 康人

× 佐々木 康人

WEKO 438270

en 佐々木 康人

Search repository
抄録
内容記述タイプ Abstract
内容記述 Aim: The purpose of this study was to assess the potential for radioimmunodetection (RAID) of murine anti-carcinoembryonic antigen (CEA) monoclonal antibody (MAb) F33-104 laveled with technetium-99m(99m-Tc) by a reduction-mediated labeling method. Methods: The binding capacity of 99m-Tc-labeled anti-CEA MAb F33-104 with CEA by means of in vitro procedures such as immunoradiometric assay and cell binding assay and the biodistribution of 99m-Tc-labeled anti-CEA MAb F33-104 in normal nude mice and nude mice bearing human colon adenocarcinoma LS180 tumor were investigated and compared with 99m-Tc-labeled anti-CEA MAb BW431/26. Results: The in vitro binding rate of 99m-Tc-labeled anti-CEA MAb F33-104 with CEA in solution and attached to the cell membrane was significantly higher than 99m-Tc-labeled anti-CEA MAb BW431/261 (31.4 0.95% vs. 11.9 0.55% at 100 ng/mL of solube CEA, 83.5 2.84% vs, 54.0 2.54% at 107 of LS 180 cells). In vivo, accumulation of 99m-Tc-labeled anti-CEA MAbF33-104 was higher at 18 h postinjection than 99m-Tc-labeled anti-CEA MAb BW431/26(20.1 3.50% ID/g vs. 14.4 3.30% ID/g). 99m-Tc-activity in the kidneys of nude mice bearing tumor was higher at 18 h postinjection than at 3 h (12.8 2.10% ID/g vs, 8.01 2.40% ID/g of 99m-Tc-labeled anti-CEA MAb F33-104, 10.7 1.70% ID/g vs. 8.10 1.75% ID/g of 99m-Tc-labeled anti-CEA MAb BW431/26). Conclusion: 99m-Tc-labeled anti-CEA MAb F33-104 is a potential novel agent for RAID of recurrent colorectal cancer.
書誌情報 Nuklearmedizin

巻 38, p. 115-119, 発行日 1999
ISSN
収録物識別子タイプ ISSN
収録物識別子 0029-5566
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-16 00:19:36.150956
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3