ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Labeling of Phosphorothioate Antisense Oligonucleotides with Yttrium-90

https://repo.qst.go.jp/records/44084
https://repo.qst.go.jp/records/44084
9efd1a71-7a13-4527-be84-e2f9247002a0
Item type 学術雑誌論文 / Journal Article(1)
公開日 2006-05-22
タイトル
タイトル Labeling of Phosphorothioate Antisense Oligonucleotides with Yttrium-90
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Watanabe, Naoyuki

× Watanabe, Naoyuki

WEKO 438236

Watanabe, Naoyuki

Search repository
Endou, Keigo

× Endou, Keigo

WEKO 438237

Endou, Keigo

Search repository
Tanada, Shuji

× Tanada, Shuji

WEKO 438238

Tanada, Shuji

Search repository
Murata, Hajime

× Murata, Hajime

WEKO 438239

Murata, Hajime

Search repository
Sasaki, Yasuhito

× Sasaki, Yasuhito

WEKO 438240

Sasaki, Yasuhito

Search repository
et.al

× et.al

WEKO 438241

et.al

Search repository
渡辺 直行

× 渡辺 直行

WEKO 438242

en 渡辺 直行

Search repository
遠藤 啓吾

× 遠藤 啓吾

WEKO 438243

en 遠藤 啓吾

Search repository
棚田 修二

× 棚田 修二

WEKO 438244

en 棚田 修二

Search repository
村田 啓

× 村田 啓

WEKO 438245

en 村田 啓

Search repository
佐々木 康人

× 佐々木 康人

WEKO 438246

en 佐々木 康人

Search repository
抄録
内容記述タイプ Abstract
内容記述 Novel yttrium-90 (90Y)-labeled phosphorothioate antisense oligonucleotides were designed as a potential targeted radionuclede therapeutic agent for malignant tumors. A 15-mer phosphorothioate antisense oligonucleotide, which was complementary to the translation start region of the N-myc oncogene mRNA, was conjugated with isothiocyanobenzyl ethylenediamine tetraacetic acid (SCN-Bn-EDTA), via a C-5-substituted deoxyuridine that had replaced a thymine in the oligonucleotide, and wa then labeled with 90Y-acetate. Following purification, the radiochemical purity of hte 90Y-Bn-EDTA-phosphorothioate antisence oligonucleotides was estimated by 2.0% agarose gel electrophoresis, and the specific hybridization of 90Y-Bn-EDTA-phosphorothioate antisense oligonucleotide to a phosphorodiester sense oligonucleotide was investigated by 20% polyacrylamide gel electrophoresis in a cell-free system. Radiochemical purity was 98.7 0.4% at 72 h after labeling and 90.3 0.9% after 72-h incubation with human normal serum. The 90Y-Bn-EDTA-phosphorothioate antisense oligonucleotide hybridized specifically to a complementary phosphorodiester sense oligonucleotide. In conclusion, phosphorothioate antisense oligonucleotides can be labeled stably with 90Y using SCN-Bn-EDTA without loss of hybridization properties.
書誌情報 Nuclear Medicine and Biology

巻 26, 号 2, p. 239-243, 発行日 1999
ISSN
収録物識別子タイプ ISSN
収録物識別子 0969-8051
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-16 00:19:37.537727
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3