  1. 原著論文

EFFECT OF CALCIUM TRISODIUM DTPA IN RATS WITH PUNCTURE WOUND CONTAMINATED BY 90Y-CHLORIDE

https://repo.qst.go.jp/records/43739
https://repo.qst.go.jp/records/43739
471d05cb-00a0-4958-984f-b4fdcdd0e265
Item type 学術雑誌論文 / Journal Article(1)
公開日 2005-07-20
タイトル
タイトル EFFECT OF CALCIUM TRISODIUM DTPA IN RATS WITH PUNCTURE WOUND CONTAMINATED BY 90Y-CHLORIDE
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Watanabe, Naoyuki

× Watanabe, Naoyuki

WEKO 434869

Watanabe, Naoyuki

Search repository
Tanada, Shuji

× Tanada, Shuji

WEKO 434870

Tanada, Shuji

Search repository
Sasaki, Yasuhito

× Sasaki, Yasuhito

WEKO 434871

Sasaki, Yasuhito

Search repository
渡辺 直行

× 渡辺 直行

WEKO 434872

en 渡辺 直行

Search repository
棚田 修二

× 棚田 修二

WEKO 434873

en 棚田 修二

Search repository
佐々木 康人

× 佐々木 康人

WEKO 434874

en 佐々木 康人

Search repository
抄録
内容記述タイプ Abstract
内容記述 The efficacy of diethylenetriaminepentaacetate calcium trisodium (CaNa3DTPA) in a dese of 34.7 mol kg-1 as a function of its route of administration was investigated in rats with a puncture wound contaminated by 90Y-chloride at a concentration of 2.55 MBq kg-1. Approximately 60% of 90Y-chloride at a puncture wound was absorbed into the body of rats over 72 h post-puncture and radioactivity in gemoral bone increased during the timed-release of 90Y. Intravenous administration of CaNaDTPA (systemic treatment) at 15 min post-puncture reduced 90Y at a puncture wound and in bone up to 75.6 and 84.3% of controls, respectively. Direct infiltration of CaNaDTPA into a puncture wound site (local treatment) at 15 min post-punctre diminished radioactivity at the puncture wound and in bone up to 34.9 and 52.5% of controls, respectively.
Thus, prompt local treatment may be effective for removing 90Y from a puncture wound and minimising 90Y-distribution to bone compared with systemic treatment.
書誌情報 Radiation Protection Dosimetry

巻 114, 号 4, p. 509-513, 発行日 2005-05
ISSN
収録物識別子タイプ ISSN
収録物識別子 0144-8420
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-16 00:23:38.311676
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3