  1. 原著論文

Characteristics of fast beam switching for spot scanning

https://repo.qst.go.jp/records/43541
https://repo.qst.go.jp/records/43541
485a204e-d3a6-41b9-9376-75f20dc768af
Item type 学術雑誌論文 / Journal Article(1)
公開日 2004-11-16
タイトル
タイトル Characteristics of fast beam switching for spot scanning
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Furukawa, Takuji

× Furukawa, Takuji

WEKO 432973

Furukawa, Takuji

Search repository
Noda, Kouji

× Noda, Kouji

WEKO 432974

Noda, Kouji

Search repository
Urakabe, Eriko

× Urakabe, Eriko

WEKO 432975

Urakabe, Eriko

Search repository
Muramatsu, Masayuki

× Muramatsu, Masayuki

WEKO 432976

Muramatsu, Masayuki

Search repository
Kanazawa, Mitsutaka

× Kanazawa, Mitsutaka

WEKO 432977

Kanazawa, Mitsutaka

Search repository
古川 卓司

× 古川 卓司

WEKO 432978

en 古川 卓司

Search repository
野田 耕司

× 野田 耕司

WEKO 432979

en 野田 耕司

Search repository
新谷 恵理子

× 新谷 恵理子

WEKO 432980

en 新谷 恵理子

Search repository
村松 正幸

× 村松 正幸

WEKO 432981

en 村松 正幸

Search repository
金澤 光隆

× 金澤 光隆

WEKO 432982

en 金澤 光隆

Search repository
抄録
内容記述タイプ Abstract
内容記述 An irradiation method for spot scanning has been developed in order to provide accurate irradiation even for an irregular target shape. In spot scanning irradiation, the beam is turned off while the beam position is shifted to the next spot for precise dose management. Recently, the fast beam cut-off method, which can achieve a cut-off time of around 50 micro sec, was proposed and verified at the HIMAC synchrotron. In order to utilize such a speciality of the technique for spot scanning, the characteristics of fast beam switching were investigated while turning on/off both the transverse and longitudinal RF fields many times during a single flattop. As a result, it was verified that this technique provides more than 50 spots during a single flattop in the synchrotron operation pattern with a cut-off time of 50 ms. With an increase in a switching number, the momentum spread and the size of the extracted beam increase within the allowable range for practical usage.
書誌情報 Nuclear Instruments & Methods in Physics Research Section A

巻 503, p. 485-495, 発行日 2003-05
ISSN
収録物識別子タイプ ISSN
収録物識別子 0168-9002
戻る
0
views
See details
Views