WEKO3
アイテム
{"_buckets": {"deposit": "dd3729be-5647-4a2f-b186-164d56d8f5a7"}, "_deposit": {"created_by": 1, "id": "86014", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "86014"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00086014", "sets": ["29"]}, "author_link": ["1041837", "1041827", "1041832", "1041830", "1041829", "1041835", "1041828", "1041825", "1041831", "1041834", "1041833", "1041826", "1041839", "1041838", "1041836", "1041824"], "item_10005_date_7": {"attribute_name": "発表年月日", "attribute_value_mlt": [{"subitem_date_issued_datetime": "2022-04-17", "subitem_date_issued_type": "Issued"}]}, "item_10005_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "[Purpose] The crosshair light sharing (CLS) PET detector, which has depth-of-interaction (DOI) capability, was recently developed by our group. In this work, as the first practical system based on the CLS detector, we developed a high-resolution portable small-animal PET with a long axial field-of-view (FOV) of 20 cm. \n\n[Methods] The system was composed of 128 CLS detectors*, which consisted of GFAG crystals and SiPMs. All devices were mounted on a compact pushcart (740 mm × 950 mm), and the system worked with a power supply from a typical wall socket of AC100V. The axial FOV was 207 mm, which covered a total-body of rat. Performance characterization was performed according to the NEMA NU4 standards. In addition, a 22Na ultra-micro hot phantom was used for spatial resolution measurement, and normal mouse and rat PET imaging with 18F-NaF and 18F-FDG was performed for imaging demonstration. \n\n[Results] The developed CLS-PET system successfully resolved 0.75 mm rods of the ultra-micro hot phantom. The sensitivity was 1.1% at the FOV center and the peak noise-equivalent count rate was 62 kcps@76 kBq/mL. The coincidence timing resolution was 496 ps. For the NaF-PET, mouse and rat total-body images were obtained, and detailed bone structures were clearly observed. For the mouse FDG-PET, cardiac FDG uptakes were clearly visualized. \n\n[Conclusion] The CLS-PET system achieved sub-mm spatial resolution and successfully provided mouse and rat total-body images. This portable small-animal PET system can offer opportunities for novel applications such as studies on PET-guided radiation therapy and PET-guided surgery.\n*Yoshida, et al. Phys Med Biol. 2021;66:065013.\n", "subitem_description_type": "Abstract"}]}, "item_10005_description_6": {"attribute_name": "会議概要(会議名, 開催地, 会期, 主催者等)", "attribute_value_mlt": [{"subitem_description": "第123回日本医学物理学会学術大会", "subitem_description_type": "Other"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Go, Akamatsu"}], "nameIdentifiers": [{"nameIdentifier": "1041824", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Eiji, Yoshida"}], "nameIdentifiers": [{"nameIdentifier": "1041825", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hideaki, Tashima"}], "nameIdentifiers": [{"nameIdentifier": "1041826", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Shigeki, Ito"}], "nameIdentifiers": [{"nameIdentifier": "1041827", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yuma, Iwao"}], "nameIdentifiers": [{"nameIdentifier": "1041828", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hidekatsu, Wakizaka"}], "nameIdentifiers": [{"nameIdentifier": "1041829", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Miwako, Takahashi"}], "nameIdentifiers": [{"nameIdentifier": "1041830", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Taiga, Yamaya"}], "nameIdentifiers": [{"nameIdentifier": "1041831", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Go, Akamatsu", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "1041832", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Eiji, Yoshida", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "1041833", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hideaki, Tashima", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "1041834", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Shigeki, Ito", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "1041835", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yuma, Iwao", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "1041836", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hidekatsu, Wakizaka", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "1041837", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Miwako, Takahashi", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "1041838", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Taiga, Yamaya", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "1041839", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference object", "resourceuri": "http://purl.org/coar/resource_type/c_c94f"}]}, "item_title": "CLS-PET: a high-resolution portable small-animal PET with a 20 cm axial FOV", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "CLS-PET: a high-resolution portable small-animal PET with a 20 cm axial FOV"}]}, "item_type_id": "10005", "owner": "1", "path": ["29"], "permalink_uri": "https://repo.qst.go.jp/records/86014", "pubdate": {"attribute_name": "公開日", "attribute_value": "2022-04-07"}, "publish_date": "2022-04-07", "publish_status": "0", "recid": "86014", "relation": {}, "relation_version_is_last": true, "title": ["CLS-PET: a high-resolution portable small-animal PET with a 20 cm axial FOV"], "weko_shared_id": -1}
CLS-PET: a high-resolution portable small-animal PET with a 20 cm axial FOV
https://repo.qst.go.jp/records/86014
https://repo.qst.go.jp/records/86014c759f925-ae97-4b61-858e-b772005013d5
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2022-04-07 | |||||
タイトル | ||||||
タイトル | CLS-PET: a high-resolution portable small-animal PET with a 20 cm axial FOV | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Go, Akamatsu
× Go, Akamatsu× Eiji, Yoshida× Hideaki, Tashima× Shigeki, Ito× Yuma, Iwao× Hidekatsu, Wakizaka× Miwako, Takahashi× Taiga, Yamaya× Go, Akamatsu× Eiji, Yoshida× Hideaki, Tashima× Shigeki, Ito× Yuma, Iwao× Hidekatsu, Wakizaka× Miwako, Takahashi× Taiga, Yamaya |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | [Purpose] The crosshair light sharing (CLS) PET detector, which has depth-of-interaction (DOI) capability, was recently developed by our group. In this work, as the first practical system based on the CLS detector, we developed a high-resolution portable small-animal PET with a long axial field-of-view (FOV) of 20 cm. [Methods] The system was composed of 128 CLS detectors*, which consisted of GFAG crystals and SiPMs. All devices were mounted on a compact pushcart (740 mm × 950 mm), and the system worked with a power supply from a typical wall socket of AC100V. The axial FOV was 207 mm, which covered a total-body of rat. Performance characterization was performed according to the NEMA NU4 standards. In addition, a 22Na ultra-micro hot phantom was used for spatial resolution measurement, and normal mouse and rat PET imaging with 18F-NaF and 18F-FDG was performed for imaging demonstration. [Results] The developed CLS-PET system successfully resolved 0.75 mm rods of the ultra-micro hot phantom. The sensitivity was 1.1% at the FOV center and the peak noise-equivalent count rate was 62 kcps@76 kBq/mL. The coincidence timing resolution was 496 ps. For the NaF-PET, mouse and rat total-body images were obtained, and detailed bone structures were clearly observed. For the mouse FDG-PET, cardiac FDG uptakes were clearly visualized. [Conclusion] The CLS-PET system achieved sub-mm spatial resolution and successfully provided mouse and rat total-body images. This portable small-animal PET system can offer opportunities for novel applications such as studies on PET-guided radiation therapy and PET-guided surgery. *Yoshida, et al. Phys Med Biol. 2021;66:065013. |
|||||
会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
内容記述タイプ | Other | |||||
内容記述 | 第123回日本医学物理学会学術大会 | |||||
発表年月日 | ||||||
日付 | 2022-04-17 | |||||
日付タイプ | Issued |