{"_buckets": {"deposit": "4aee33e2-b38d-48e2-86f1-c11a8a79b0b3"}, "_deposit": {"created_by": 1, "id": "83625", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "83625"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00083625", "sets": ["28"]}, "author_link": ["1007730", "1007729"], "item_10005_date_7": {"attribute_name": "発表年月日", "attribute_value_mlt": [{"subitem_date_issued_datetime": "2021-10-22", "subitem_date_issued_type": "Issued"}]}, "item_10005_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "For mouse brain dedicated positron emission tomography (PET), depth-of-interaction (DOI) information is necessary to provide high resolution without compromising the sensitivity. In this study, we designed mouse brain PET with a staggered 4-layer DOI detector using 1 mm crystal pitch for high-resolution molecular imaging research. The proposed PET had a 50 mm ring diameter and 11 mm axial FOV. The proof-of-concept experimental results obtained with a single DOI detector showed good crystal map quality, resolving 95% of the crystals. Based on those results, we conducted GATE simulations to optimize the crystal layer configuration which can provide the best spatial resolution throughout the field-of-view. Three different crystal layer configurations were used: (1) uniform crystal layer (5+5+5+5 mm), (2) heterogenous crystal layer (3+3+4+10 mm), and (3) heterogenous crystal layer with a total thickness of 17 mm (3+3+4+7 mm). To evaluate the spatial resolution, five cylindrical sources (D=0.1 mm, L=10 mm) with spacing of 5 mm in the radial direction were used. In addition, an ultra-micro hot phantom was used to evaluate the imaging performance. The PET images were reconstructed by using an OSEM algorithm with 8 subsets and 10 iterations. An energy window of 400-600 keV was used for the image reconstruction and sensitivity calculation. The heterogenous crystal layer configuration (3+3+4+7 mm) showed the best spatial resolution (0.45 mm at center and 0.74 mm at 10 mm radial offset) among the three. The 0.75 mm rods of the ultra-micro hot phantom could be resolved with the peak-to-valley ratio of 1.57. In conclusion, the mouse brain PET with a staggered 4-layer DOI detector using the heterogenous crystal layer configuration (3+3+4+7 mm) can provide submillimeter resolution and 1.35% sensitivity. In the future, we plan to develop a prototype mouse brain PET scanner to validate the simulation results.", "subitem_description_type": "Abstract"}]}, "item_10005_description_6": {"attribute_name": "会議概要(会議名, 開催地, 会期, 主催者等)", "attribute_value_mlt": [{"subitem_description": "2021 Virtual IEEE Nuclear Science Symposium and Medical Imaging Conference", "subitem_description_type": "Other"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Kang, Hangyu"}], "nameIdentifiers": [{"nameIdentifier": "1007729", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kang, Hangyu", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "1007730", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference object", "resourceuri": "http://purl.org/coar/resource_type/c_c94f"}]}, "item_title": "Mouse Brain PET with a Staggered 4-Layer DOI Detector – Optimized Crystal Layer with GATE", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Mouse Brain PET with a Staggered 4-Layer DOI Detector – Optimized Crystal Layer with GATE"}]}, "item_type_id": "10005", "owner": "1", "path": ["28"], "permalink_uri": "https://repo.qst.go.jp/records/83625", "pubdate": {"attribute_name": "公開日", "attribute_value": "2021-10-15"}, "publish_date": "2021-10-15", "publish_status": "0", "recid": "83625", "relation": {}, "relation_version_is_last": true, "title": ["Mouse Brain PET with a Staggered 4-Layer DOI Detector – Optimized Crystal Layer with GATE"], "weko_shared_id": -1}
Mouse Brain PET with a Staggered 4-Layer DOI Detector – Optimized Crystal Layer with GATE
https://repo.qst.go.jp/records/83625
https://repo.qst.go.jp/records/83625b6f3a619-41f5-4e5b-b951-d6379bb0e7d3
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2021-10-15 | |||||
タイトル | ||||||
タイトル | Mouse Brain PET with a Staggered 4-Layer DOI Detector – Optimized Crystal Layer with GATE | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Kang, Hangyu
× Kang, Hangyu× Kang, Hangyu |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | For mouse brain dedicated positron emission tomography (PET), depth-of-interaction (DOI) information is necessary to provide high resolution without compromising the sensitivity. In this study, we designed mouse brain PET with a staggered 4-layer DOI detector using 1 mm crystal pitch for high-resolution molecular imaging research. The proposed PET had a 50 mm ring diameter and 11 mm axial FOV. The proof-of-concept experimental results obtained with a single DOI detector showed good crystal map quality, resolving 95% of the crystals. Based on those results, we conducted GATE simulations to optimize the crystal layer configuration which can provide the best spatial resolution throughout the field-of-view. Three different crystal layer configurations were used: (1) uniform crystal layer (5+5+5+5 mm), (2) heterogenous crystal layer (3+3+4+10 mm), and (3) heterogenous crystal layer with a total thickness of 17 mm (3+3+4+7 mm). To evaluate the spatial resolution, five cylindrical sources (D=0.1 mm, L=10 mm) with spacing of 5 mm in the radial direction were used. In addition, an ultra-micro hot phantom was used to evaluate the imaging performance. The PET images were reconstructed by using an OSEM algorithm with 8 subsets and 10 iterations. An energy window of 400-600 keV was used for the image reconstruction and sensitivity calculation. The heterogenous crystal layer configuration (3+3+4+7 mm) showed the best spatial resolution (0.45 mm at center and 0.74 mm at 10 mm radial offset) among the three. The 0.75 mm rods of the ultra-micro hot phantom could be resolved with the peak-to-valley ratio of 1.57. In conclusion, the mouse brain PET with a staggered 4-layer DOI detector using the heterogenous crystal layer configuration (3+3+4+7 mm) can provide submillimeter resolution and 1.35% sensitivity. In the future, we plan to develop a prototype mouse brain PET scanner to validate the simulation results. | |||||