WEKO3
アイテム
{"_buckets": {"deposit": "e7e13ac4-0abf-44e5-b105-8b7b8d97a8f6"}, "_deposit": {"created_by": 1, "id": "81372", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "81372"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00081372", "sets": ["7"]}, "author_link": ["910697", "910698"], "item_10004_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2017-06", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "6", "bibliographicPageEnd": "476", "bibliographicPageStart": "469", "bibliographicVolumeNumber": "73", "bibliographic_titles": [{"bibliographic_title": "日本放射線技術学会雑誌"}]}]}, "item_10004_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "国際放射線防護委員会(InternationalCommissiononRadiologicalProtection:ICRP)は,Publication73ʠRadiologicalProtectionandSafetyinMedicineʡ1)(「医学における放射線の防護と安全」)の中で「診断参考レベル(DiagnosticReferenceLevels:DRLs)」の考え方を導入した.更に,Publication103ʠThe2007RecommendationsoftheInternationalCommissiononRadiologicalProtectionʡ2)(「国際放射線防護委員会の2007年勧告」)では,医療放射線防護が「7.患者,介助者と介護者,生物医学研究志願者の医療被ばく」として章が独立し,「7.2.1.診断参考レベル」に記述された.放射線防護体系の中に明記されて以来,数多くの組織・国々で医療被ばく線量の調査が行われ,それらのデータを基にDRLsが設定されてきた.日本でも,その重要性は関係者らに認識されていたが,医療被ばくは法令上直接の規制対象になっていないため,公的な規制に取り入れられない状況が続いていた.しかし2015年,医療被ばく研究情報ネットワーク(JapanNetworkforResearchandInformationonMedicalExposure:J-RIME)が,オールジャパンとして初のDRLsといえる「最新の国内実態調査結果に基づく診断参考レベルの設定」3)を,関連学会・団体の協力を得てとりまとめた.これ以降,少しずつ,複数の学会などで取り組みが行われ,医療従事者の関心も高まってきている.このように,日本はDRLsに関して後塵を拝しているといわざるを得ないが,逆に見れば,他国の例が参考になるといえる.そこで,海外におけるDRLsについて,読者の参考になるデータ集としても用いることができるように,ここでまとめて紹介する.", "subitem_description_type": "Abstract"}]}, "item_10004_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0369-4305", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "赤羽, 恵一"}], "nameIdentifiers": [{"nameIdentifier": "910697", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Akahane, Keiichi", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "910698", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "DRLの海外での状況", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "DRLの海外での状況"}]}, "item_type_id": "10004", "owner": "1", "path": ["7"], "permalink_uri": "https://repo.qst.go.jp/records/81372", "pubdate": {"attribute_name": "公開日", "attribute_value": "2020-12-21"}, "publish_date": "2020-12-21", "publish_status": "0", "recid": "81372", "relation": {}, "relation_version_is_last": true, "title": ["DRLの海外での状況"], "weko_shared_id": -1}
DRLの海外での状況
https://repo.qst.go.jp/records/81372
https://repo.qst.go.jp/records/81372aff40b60-c23f-4d5b-839e-ac7a5f58c578
Item type | 一般雑誌記事 / Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2020-12-21 | |||||
タイトル | ||||||
タイトル | DRLの海外での状況 | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
赤羽, 恵一
× 赤羽, 恵一× Akahane, Keiichi |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | 国際放射線防護委員会(InternationalCommissiononRadiologicalProtection:ICRP)は,Publication73ʠRadiologicalProtectionandSafetyinMedicineʡ1)(「医学における放射線の防護と安全」)の中で「診断参考レベル(DiagnosticReferenceLevels:DRLs)」の考え方を導入した.更に,Publication103ʠThe2007RecommendationsoftheInternationalCommissiononRadiologicalProtectionʡ2)(「国際放射線防護委員会の2007年勧告」)では,医療放射線防護が「7.患者,介助者と介護者,生物医学研究志願者の医療被ばく」として章が独立し,「7.2.1.診断参考レベル」に記述された.放射線防護体系の中に明記されて以来,数多くの組織・国々で医療被ばく線量の調査が行われ,それらのデータを基にDRLsが設定されてきた.日本でも,その重要性は関係者らに認識されていたが,医療被ばくは法令上直接の規制対象になっていないため,公的な規制に取り入れられない状況が続いていた.しかし2015年,医療被ばく研究情報ネットワーク(JapanNetworkforResearchandInformationonMedicalExposure:J-RIME)が,オールジャパンとして初のDRLsといえる「最新の国内実態調査結果に基づく診断参考レベルの設定」3)を,関連学会・団体の協力を得てとりまとめた.これ以降,少しずつ,複数の学会などで取り組みが行われ,医療従事者の関心も高まってきている.このように,日本はDRLsに関して後塵を拝しているといわざるを得ないが,逆に見れば,他国の例が参考になるといえる.そこで,海外におけるDRLsについて,読者の参考になるデータ集としても用いることができるように,ここでまとめて紹介する. | |||||
書誌情報 |
日本放射線技術学会雑誌 巻 73, 号 6, p. 469-476, 発行日 2017-06 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0369-4305 |