タイトル
タイトル Radiation Dose Distribution Support System by Using Nonlinear Registration method; Application for DICOM-RT Information
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Ando, Yutaka

× Ando, Yutaka

WEKO 689082

Ando, Yutaka

Search repository
Tanikawa, Takumi

× Tanikawa, Takumi

WEKO 689083

Tanikawa, Takumi

Search repository
Mukai, Masami

× Mukai, Masami

WEKO 689084

Mukai, Masami

Search repository
Kamada, Tadashi

× Kamada, Tadashi

WEKO 689085

Kamada, Tadashi

Search repository
Uemura, Koji

× Uemura, Koji

WEKO 689086

Uemura, Koji

Search repository
Tsukamoto, Nobuhiro

× Tsukamoto, Nobuhiro

WEKO 689087

Tsukamoto, Nobuhiro

Search repository
Masuzawa, Takashi

× Masuzawa, Takashi

WEKO 689088

Masuzawa, Takashi

Search repository
Osada, Masakazu

× Osada, Masakazu

WEKO 689089

Osada, Masakazu

Search repository
Seki, Masayoshi

× Seki, Masayoshi

WEKO 689090

Seki, Masayoshi

Search repository
安藤 裕

× 安藤 裕

WEKO 689091

en 安藤 裕

Search repository
谷川 琢海

× 谷川 琢海

WEKO 689092

en 谷川 琢海

Search repository
向井 まさみ

× 向井 まさみ

WEKO 689093

en 向井 まさみ

Search repository
鎌田 正

× 鎌田 正

WEKO 689094

en 鎌田 正

Search repository
上村 幸司

× 上村 幸司

WEKO 689095

en 上村 幸司

Search repository
塚本 信宏

× 塚本 信宏

WEKO 689096

en 塚本 信宏

Search repository
抄録
内容記述タイプ Abstract
内容記述 Purpose: In recent years, the precise irradiation methods, such as IMRT and heavy ion radiotherapy, have developed and used widely for cancer treatment. They have made possible correct irradiation to complicated-shaped target and greatly improved the effect of radiotherapy. Meanwhile, for the patients who receive two or more radiotherapy because of a local recurrence and/or a remote metastasis, for physicians it is necessary to plan the radiation treatment so that the dose distribution would not overlap with previous radiation. Conventionally, a radiation oncologist determine a new plan by referring to a past radiation treatment plan visually. However, this work is very complex and difficult, and high skill is required of doctors. In this study, we tried to develop a next generation system to support designing multiple treatments with reliable and effective radiation, and the nonlinear registration method for aligning the intra-subject X-ray CT images obtained on another day was examined.
The goal of this study is to combine the dose distribution of the repeated radiation therapy on the nominal CT-image atlas and to evaluate the tolerance dose of the each treated organs. This paper is the first step of the study.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 CARS2010 ( 24rd International Congress and Exhibition )
発表年月日
日付 2010-06-26
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 20:06:01.076202
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3