{"created":"2023-05-15T14:51:19.889470+00:00","id":70173,"links":{},"metadata":{"_buckets":{"deposit":"02a68cc6-a770-4279-9c0d-e65d14b9d3db"},"_deposit":{"created_by":1,"id":"70173","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"70173"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00070173","sets":["10:28"]},"author_link":["689089","689096","689094","689083","689084","689087","689095","689092","689093","689086","689091","689082","689090","689085","689088"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2010-06-26","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Purpose: In recent years, the precise irradiation methods, such as IMRT and heavy ion radiotherapy, have developed and used widely for cancer treatment. They have made possible correct irradiation to complicated-shaped target and greatly improved the effect of radiotherapy. Meanwhile, for the patients who receive two or more radiotherapy because of a local recurrence and/or a remote metastasis, for physicians it is necessary to plan the radiation treatment so that the dose distribution would not overlap with previous radiation. Conventionally, a radiation oncologist determine a new plan by referring to a past radiation treatment plan visually. However, this work is very complex and difficult, and high skill is required of doctors. In this study, we tried to develop a next generation system to support designing multiple treatments with reliable and effective radiation, and the nonlinear registration method for aligning the intra-subject X-ray CT images obtained on another day was examined.\nThe goal of this study is to combine the dose distribution of the repeated radiation therapy on the nominal CT-image atlas and to evaluate the tolerance dose of the each treated organs. This paper is the first step of the study.","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"CARS2010 ( 24rd International Congress and Exhibition )","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Ando, Yutaka"}],"nameIdentifiers":[{"nameIdentifier":"689082","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Tanikawa, Takumi"}],"nameIdentifiers":[{"nameIdentifier":"689083","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Mukai, Masami"}],"nameIdentifiers":[{"nameIdentifier":"689084","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kamada, Tadashi"}],"nameIdentifiers":[{"nameIdentifier":"689085","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Uemura, Koji"}],"nameIdentifiers":[{"nameIdentifier":"689086","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Tsukamoto, Nobuhiro"}],"nameIdentifiers":[{"nameIdentifier":"689087","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Masuzawa, Takashi"}],"nameIdentifiers":[{"nameIdentifier":"689088","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Osada, Masakazu"}],"nameIdentifiers":[{"nameIdentifier":"689089","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Seki, Masayoshi"}],"nameIdentifiers":[{"nameIdentifier":"689090","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"安藤 裕","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"689091","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"谷川 琢海","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"689092","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"向井 まさみ","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"689093","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"鎌田 正","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"689094","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"上村 幸司","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"689095","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"塚本 信宏","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"689096","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"Radiation Dose Distribution Support System by Using Nonlinear Registration method; Application for DICOM-RT Information","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Radiation Dose Distribution Support System by Using Nonlinear Registration method; Application for DICOM-RT Information"}]},"item_type_id":"10005","owner":"1","path":["28"],"pubdate":{"attribute_name":"公開日","attribute_value":"2010-06-29"},"publish_date":"2010-06-29","publish_status":"0","recid":"70173","relation_version_is_last":true,"title":["Radiation Dose Distribution Support System by Using Nonlinear Registration method; Application for DICOM-RT Information"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T20:06:00.979826+00:00"}