{"_buckets": {"deposit": "07b4fece-7fb9-4ccf-8f79-7a122b1c721e"}, "_deposit": {"created_by": 1, "id": "70036", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "70036"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00070036", "sets": ["28"]}, "author_link": ["687681", "687668", "687669", "687677", "687671", "687678", "687676", "687683", "687680", "687672", "687670", "687674", "687675", "687673", "687684", "687682", "687679"], "item_10005_date_7": {"attribute_name": "発表年月日", "attribute_value_mlt": [{"subitem_date_issued_datetime": "2009-10-30", "subitem_date_issued_type": "Issued"}]}, "item_10005_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "The aim of this study is to clarify cell cycle distribution and cytotoxicity after carbon-ion beams (C-ions). One human malignant melanoma cell line, HMV-I was exposed to X-rays or 290 MeV/u C-ions at the center of SOBP. We applied flow cytometry technique and colony formation assay. C-ions induced G2/M arrest effectively more than X-rays at 24 h. The iso-effect dose, i.e. the 10% survival dose (5.0Gy for X-rays, 2.7Gy for C-ions) was used to examine the cell cycle kinetics. G2/M fraction increased immediately after irradiations, and showed a peak at 15 h. G2/M arrest cells were stayed long time after C-ions, whereas it released quickly after X-rays. In addition, the mRNA expression of molecules related with the arrest was suppressed with D10 dose and the effects were transitory after X-rays, whereas C-ions showed prolonged suppression. The arrest was released significantly by caffeine, and the cell killing by C-ions was enhanced with caffeine together. It is suggested that the release from G2/M arrest after C-ions can enhance the cytotoxic effects. Repair of complex DNA damage by C-ions takes long time. When it released intermediate of the process, incomplete repaired damage cause cell death.", "subitem_description_type": "Abstract"}]}, "item_10005_description_6": {"attribute_name": "会議概要(会議名, 開催地, 会期, 主催者等)", "attribute_value_mlt": [{"subitem_description": "MICROS 2009 15th International Symposium on Microdosimetry", "subitem_description_type": "Other"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Matsumoto, Yoshitaka"}], "nameIdentifiers": [{"nameIdentifier": "687668", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hirayama, Ryoichi"}], "nameIdentifiers": [{"nameIdentifier": "687669", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Sai, Sei"}], "nameIdentifiers": [{"nameIdentifier": "687670", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ando, Koichi"}], "nameIdentifiers": [{"nameIdentifier": "687671", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Uzawa, Akiko"}], "nameIdentifiers": [{"nameIdentifier": "687672", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Takase, Nobuhiro"}], "nameIdentifiers": [{"nameIdentifier": "687673", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Koike, Sachiko"}], "nameIdentifiers": [{"nameIdentifier": "687674", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Okayasu, Ryuichi"}], "nameIdentifiers": [{"nameIdentifier": "687675", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Furusawa, Yoshiya"}], "nameIdentifiers": [{"nameIdentifier": "687676", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "松本 孔貴", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "687677", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "平山 亮一", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "687678", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "崔 星", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "687679", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "鵜澤 玲子", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "687680", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "高瀬 信宏", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "687681", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "小池 幸子", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "687682", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "岡安 隆一", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "687683", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "古澤 佳也", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "687684", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference object", "resourceuri": "http://purl.org/coar/resource_type/c_c94f"}]}, "item_title": "ABROGATION OF THE G2/M ARREST ENHANCED THE CYTOTOXIC EFFECTS BY CARBON-ION BEAMS", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "ABROGATION OF THE G2/M ARREST ENHANCED THE CYTOTOXIC EFFECTS BY CARBON-ION BEAMS"}]}, "item_type_id": "10005", "owner": "1", "path": ["28"], "permalink_uri": "https://repo.qst.go.jp/records/70036", "pubdate": {"attribute_name": "公開日", "attribute_value": "2010-02-19"}, "publish_date": "2010-02-19", "publish_status": "0", "recid": "70036", "relation": {}, "relation_version_is_last": true, "title": ["ABROGATION OF THE G2/M ARREST ENHANCED THE CYTOTOXIC EFFECTS BY CARBON-ION BEAMS"], "weko_shared_id": -1}
ABROGATION OF THE G2/M ARREST ENHANCED THE CYTOTOXIC EFFECTS BY CARBON-ION BEAMS
https://repo.qst.go.jp/records/70036
https://repo.qst.go.jp/records/700366f8c22f1-2256-4136-a25e-13d02f0912a7
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2010-02-19 | |||||
タイトル | ||||||
タイトル | ABROGATION OF THE G2/M ARREST ENHANCED THE CYTOTOXIC EFFECTS BY CARBON-ION BEAMS | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Matsumoto, Yoshitaka
× Matsumoto, Yoshitaka× Hirayama, Ryoichi× Sai, Sei× Ando, Koichi× Uzawa, Akiko× Takase, Nobuhiro× Koike, Sachiko× Okayasu, Ryuichi× Furusawa, Yoshiya× 松本 孔貴× 平山 亮一× 崔 星× 鵜澤 玲子× 高瀬 信宏× 小池 幸子× 岡安 隆一× 古澤 佳也 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | The aim of this study is to clarify cell cycle distribution and cytotoxicity after carbon-ion beams (C-ions). One human malignant melanoma cell line, HMV-I was exposed to X-rays or 290 MeV/u C-ions at the center of SOBP. We applied flow cytometry technique and colony formation assay. C-ions induced G2/M arrest effectively more than X-rays at 24 h. The iso-effect dose, i.e. the 10% survival dose (5.0Gy for X-rays, 2.7Gy for C-ions) was used to examine the cell cycle kinetics. G2/M fraction increased immediately after irradiations, and showed a peak at 15 h. G2/M arrest cells were stayed long time after C-ions, whereas it released quickly after X-rays. In addition, the mRNA expression of molecules related with the arrest was suppressed with D10 dose and the effects were transitory after X-rays, whereas C-ions showed prolonged suppression. The arrest was released significantly by caffeine, and the cell killing by C-ions was enhanced with caffeine together. It is suggested that the release from G2/M arrest after C-ions can enhance the cytotoxic effects. Repair of complex DNA damage by C-ions takes long time. When it released intermediate of the process, incomplete repaired damage cause cell death. | |||||
会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
内容記述タイプ | Other | |||||
内容記述 | MICROS 2009 15th International Symposium on Microdosimetry | |||||
発表年月日 | ||||||
日付 | 2009-10-30 | |||||
日付タイプ | Issued |