{"_buckets": {"deposit": "6f0bf3fd-1691-4ccc-9e09-45430818e507"}, "_deposit": {"created_by": 1, "id": "69909", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "69909"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00069909", "sets": ["28"]}, "author_link": ["686429", "686418", "686420", "686427", "686425", "686426", "686421", "686419", "686424", "686422", "686428", "686423"], "item_10005_date_7": {"attribute_name": "発表年月日", "attribute_value_mlt": [{"subitem_date_issued_datetime": "2009-10-14", "subitem_date_issued_type": "Issued"}]}, "item_10005_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Aim: In the radiation therapy, normal bone marrow is often included in radiation field inevitably. The aim of this study was to investigate the change in 3\u0027-18F-fluoro-3\u0027-deoxy-L-thymidine (FLT) uptake to normal bone marrow after inevitable radiation.\nMethods: Twenty-one non-small cell lung cancer (NSCLC) patients who received carbon ion radiotherapy (CIRT) were studied with regard to bone marrow activity by FLT PET/CT. CIRT was performed with three protocols (42-44 GyE/1 fraction in 9 patients, 52.8-60 GyE/4 fractions in 10 patients, and 62.8 GyE/12 fractions in 2 patients). These dose and fraction pairs gave the similar clinical tumor response results. Radiation dose to bone marrow was calculated by three dimensional CT planning system. FLT PET/CT studies were carried out before and after CIRT. Post-CIRT FLT studies were performed at 1 or 2 day after CIRT (6 patients), 3 months after CIRT (20 patients) and more than 1 year after CIRT (3 patients). FLT uptake was evaluated visually and by a maximum standard uptake value (SUVmax). In some evaluations, the ratio of uptake of irradiated marrow to non-irradiated counterpart was used. As non-irradiated control sites, changes in lumbar (L2-5) bone marrow FLT uptake were measured. Irradiated bone marrow was divided into 2 two groups (10-30 % of maximum dose, and more than 30% of maximum dose), and the changes of FLT uptake were measured.\nResults: Ribs were included in the radiation field in all patients; spine in 2 patients, scapula in 7 patients, and sternum in 2 patients. FLT uptake in the bone marrow receiving the 10 % dose or more clearly decreased at all time points after CIRT in comparison with pre-irradiation values. The FLT uptake was the lowest just after CIRT, somewhat recovered at 3 months, and remained unchanged for more than 1 year. There was no significant difference in reduction of FLT uptake between the area receiving 10-30% dose and those receiving more than 30%. FLT uptake to non-irradiated areas (L2-5) was not changed after CIRT.\nConclusion: Bone marrow receiving as low as 10% dose of carbon ion showed clearly decreased FLT uptake. Bone marrow cells are considered sensitive to low dose. FLT-PET can sensitively detect these changes and may help to confirm the radiation field.", "subitem_description_type": "Abstract"}]}, "item_10005_description_6": {"attribute_name": "会議概要(会議名, 開催地, 会期, 主催者等)", "attribute_value_mlt": [{"subitem_description": "Annual Congress of the European Association of Nuclear Medicine 2009", "subitem_description_type": "Other"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Koizumi, Mitsuru"}], "nameIdentifiers": [{"nameIdentifier": "686418", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Saga, Tsuneo"}], "nameIdentifiers": [{"nameIdentifier": "686419", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Inubushi, Masayuki"}], "nameIdentifiers": [{"nameIdentifier": "686420", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yoshikawa, Kyosan"}], "nameIdentifiers": [{"nameIdentifier": "686421", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Fukumura, Toshimitsu"}], "nameIdentifiers": [{"nameIdentifier": "686422", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Baba, Masayuki"}], "nameIdentifiers": [{"nameIdentifier": "686423", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "小泉 満", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "686424", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "佐賀 恒夫", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "686425", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "犬伏 正幸", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "686426", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "吉川 京燦", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "686427", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "福村 利光", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "686428", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "馬場 雅行", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "686429", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference object", "resourceuri": "http://purl.org/coar/resource_type/c_c94f"}]}, "item_title": "Evaluation of Bone Marrow Activity after Carbon-Ion Radiotherapy by PET/CT Using a Proliferative Tracer, FLT", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Evaluation of Bone Marrow Activity after Carbon-Ion Radiotherapy by PET/CT Using a Proliferative Tracer, FLT"}]}, "item_type_id": "10005", "owner": "1", "path": ["28"], "permalink_uri": "https://repo.qst.go.jp/records/69909", "pubdate": {"attribute_name": "公開日", "attribute_value": "2009-10-23"}, "publish_date": "2009-10-23", "publish_status": "0", "recid": "69909", "relation": {}, "relation_version_is_last": true, "title": ["Evaluation of Bone Marrow Activity after Carbon-Ion Radiotherapy by PET/CT Using a Proliferative Tracer, FLT"], "weko_shared_id": -1}
Evaluation of Bone Marrow Activity after Carbon-Ion Radiotherapy by PET/CT Using a Proliferative Tracer, FLT
https://repo.qst.go.jp/records/69909
https://repo.qst.go.jp/records/69909f1779cf5-769f-4258-9939-e07f8a0a2000
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2009-10-23 | |||||
タイトル | ||||||
タイトル | Evaluation of Bone Marrow Activity after Carbon-Ion Radiotherapy by PET/CT Using a Proliferative Tracer, FLT | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Koizumi, Mitsuru
× Koizumi, Mitsuru× Saga, Tsuneo× Inubushi, Masayuki× Yoshikawa, Kyosan× Fukumura, Toshimitsu× Baba, Masayuki× 小泉 満× 佐賀 恒夫× 犬伏 正幸× 吉川 京燦× 福村 利光× 馬場 雅行 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Aim: In the radiation therapy, normal bone marrow is often included in radiation field inevitably. The aim of this study was to investigate the change in 3'-18F-fluoro-3'-deoxy-L-thymidine (FLT) uptake to normal bone marrow after inevitable radiation. Methods: Twenty-one non-small cell lung cancer (NSCLC) patients who received carbon ion radiotherapy (CIRT) were studied with regard to bone marrow activity by FLT PET/CT. CIRT was performed with three protocols (42-44 GyE/1 fraction in 9 patients, 52.8-60 GyE/4 fractions in 10 patients, and 62.8 GyE/12 fractions in 2 patients). These dose and fraction pairs gave the similar clinical tumor response results. Radiation dose to bone marrow was calculated by three dimensional CT planning system. FLT PET/CT studies were carried out before and after CIRT. Post-CIRT FLT studies were performed at 1 or 2 day after CIRT (6 patients), 3 months after CIRT (20 patients) and more than 1 year after CIRT (3 patients). FLT uptake was evaluated visually and by a maximum standard uptake value (SUVmax). In some evaluations, the ratio of uptake of irradiated marrow to non-irradiated counterpart was used. As non-irradiated control sites, changes in lumbar (L2-5) bone marrow FLT uptake were measured. Irradiated bone marrow was divided into 2 two groups (10-30 % of maximum dose, and more than 30% of maximum dose), and the changes of FLT uptake were measured. Results: Ribs were included in the radiation field in all patients; spine in 2 patients, scapula in 7 patients, and sternum in 2 patients. FLT uptake in the bone marrow receiving the 10 % dose or more clearly decreased at all time points after CIRT in comparison with pre-irradiation values. The FLT uptake was the lowest just after CIRT, somewhat recovered at 3 months, and remained unchanged for more than 1 year. There was no significant difference in reduction of FLT uptake between the area receiving 10-30% dose and those receiving more than 30%. FLT uptake to non-irradiated areas (L2-5) was not changed after CIRT. Conclusion: Bone marrow receiving as low as 10% dose of carbon ion showed clearly decreased FLT uptake. Bone marrow cells are considered sensitive to low dose. FLT-PET can sensitively detect these changes and may help to confirm the radiation field. |
|||||
会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
内容記述タイプ | Other | |||||
内容記述 | Annual Congress of the European Association of Nuclear Medicine 2009 | |||||
発表年月日 | ||||||
日付 | 2009-10-14 | |||||
日付タイプ | Issued |