WEKO3
アイテム
{"_buckets": {"deposit": "09f97f0d-b8d4-41ca-8565-dc680031af13"}, "_deposit": {"created_by": 1, "id": "69300", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "69300"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00069300", "sets": ["28"]}, "author_link": ["680071", "680073", "680065", "680068", "680076", "680072", "680066", "680070", "680075", "680067", "680069", "680074"], "item_10005_date_7": {"attribute_name": "発表年月日", "attribute_value_mlt": [{"subitem_date_issued_datetime": "2008-03-15", "subitem_date_issued_type": "Issued"}]}, "item_10005_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Introduction: High LET carbon ion beam cancer therapy at National Institute of Radiological Sciences (Chiba, Japan) began in 1994. Considering the expansion of heavy-ion cancer therapy, the quality and accuracy of the heavy-ion therapy must be improved and optimized. Detection of free radical reactions and geometry in a large sample irradiated by a heavy-ion beam is thus important to understand the effect of high LET irradiation in patients. Therefore, a new method to detect free radical generation, which can be translated to an imaging technique, is required. In this experiment, using an X-ray irradiation, the imaging-translational detection of H2O2 generation in an aqueous sample was tested. Method: LiPc crystal was put into a plastic microtube. The microtube was filled with mili-Q water or PBS, and sealed air-tightly without any bubble in the tube. The tube was irradiated by X-ray (Eeff = 80 keV) with dose of 256 Gy. After the irradiation, EPR spectra of LiPc in the tube were measured at L-band (1.2 GHz). The pO2 value in the tube was estimated from the linewidth of EPR spectrum of LiPc. A similar sample without LiPc was irradiated by X-ray (256 Gy), and then H2O2 concentration in the tube was measured. A water solution of TEMPOL (2 mM) was irradiated by X-ray (356 Gy), and the reduction of the EPR signal of TEMPOL was measured. Results and Discussion: By irradiating 256 Gy of X-ray, pO2 in the irradiated water was decreased by 30 mmHg, and generation of 60 \u0026#61549;mol/L H2O2 in the irradiated water was detected. When a water solution of TEMPOL (2 mM) was irradiated by 256 Gy of X-ray, EPR signal of TEMPOL in the sample was decreased. The H2O2 generated in the water during the irradiation can make the reduction of TEMPOL without hydrogen-donor, such as GSH, NADH, or NADPH. This experimental design will be translated to imaging experiment and applied to the high LET radiation such as heavy-ion beams in the future.", "subitem_description_type": "Abstract"}]}, "item_10005_description_6": {"attribute_name": "会議概要(会議名, 開催地, 会期, 主催者等)", "attribute_value_mlt": [{"subitem_description": "Oxygen Club of California 2008 World Congress", "subitem_description_type": "Other"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Matsumoto, Kenichiro"}], "nameIdentifiers": [{"nameIdentifier": "680065", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Matsumoto, Atsuko"}], "nameIdentifiers": [{"nameIdentifier": "680066", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Nyuui, Minako"}], "nameIdentifiers": [{"nameIdentifier": "680067", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ueno, Megumi"}], "nameIdentifiers": [{"nameIdentifier": "680068", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Manda, Sushma"}], "nameIdentifiers": [{"nameIdentifier": "680069", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Anzai, Kazunori"}], "nameIdentifiers": [{"nameIdentifier": "680070", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "松本 謙一郎", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "680071", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "松本 厚子", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "680072", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "乳井 美奈子", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "680073", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "上野 恵美", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "680074", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Manda Sushma", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "680075", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "安西 和紀", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "680076", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference object", "resourceuri": "http://purl.org/coar/resource_type/c_c94f"}]}, "item_title": "Free radical reaction and oxygen consumption in an aqueous solution by an X-ray irradiation", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Free radical reaction and oxygen consumption in an aqueous solution by an X-ray irradiation"}]}, "item_type_id": "10005", "owner": "1", "path": ["28"], "permalink_uri": "https://repo.qst.go.jp/records/69300", "pubdate": {"attribute_name": "公開日", "attribute_value": "2008-03-18"}, "publish_date": "2008-03-18", "publish_status": "0", "recid": "69300", "relation": {}, "relation_version_is_last": true, "title": ["Free radical reaction and oxygen consumption in an aqueous solution by an X-ray irradiation"], "weko_shared_id": -1}
Free radical reaction and oxygen consumption in an aqueous solution by an X-ray irradiation
https://repo.qst.go.jp/records/69300
https://repo.qst.go.jp/records/6930079dba92f-b737-4cf4-bc4f-4783fb53e49c
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2008-03-18 | |||||
タイトル | ||||||
タイトル | Free radical reaction and oxygen consumption in an aqueous solution by an X-ray irradiation | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Matsumoto, Kenichiro
× Matsumoto, Kenichiro× Matsumoto, Atsuko× Nyuui, Minako× Ueno, Megumi× Manda, Sushma× Anzai, Kazunori× 松本 謙一郎× 松本 厚子× 乳井 美奈子× 上野 恵美× Manda Sushma× 安西 和紀 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Introduction: High LET carbon ion beam cancer therapy at National Institute of Radiological Sciences (Chiba, Japan) began in 1994. Considering the expansion of heavy-ion cancer therapy, the quality and accuracy of the heavy-ion therapy must be improved and optimized. Detection of free radical reactions and geometry in a large sample irradiated by a heavy-ion beam is thus important to understand the effect of high LET irradiation in patients. Therefore, a new method to detect free radical generation, which can be translated to an imaging technique, is required. In this experiment, using an X-ray irradiation, the imaging-translational detection of H2O2 generation in an aqueous sample was tested. Method: LiPc crystal was put into a plastic microtube. The microtube was filled with mili-Q water or PBS, and sealed air-tightly without any bubble in the tube. The tube was irradiated by X-ray (Eeff = 80 keV) with dose of 256 Gy. After the irradiation, EPR spectra of LiPc in the tube were measured at L-band (1.2 GHz). The pO2 value in the tube was estimated from the linewidth of EPR spectrum of LiPc. A similar sample without LiPc was irradiated by X-ray (256 Gy), and then H2O2 concentration in the tube was measured. A water solution of TEMPOL (2 mM) was irradiated by X-ray (356 Gy), and the reduction of the EPR signal of TEMPOL was measured. Results and Discussion: By irradiating 256 Gy of X-ray, pO2 in the irradiated water was decreased by 30 mmHg, and generation of 60 mol/L H2O2 in the irradiated water was detected. When a water solution of TEMPOL (2 mM) was irradiated by 256 Gy of X-ray, EPR signal of TEMPOL in the sample was decreased. The H2O2 generated in the water during the irradiation can make the reduction of TEMPOL without hydrogen-donor, such as GSH, NADH, or NADPH. This experimental design will be translated to imaging experiment and applied to the high LET radiation such as heavy-ion beams in the future. | |||||
会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
内容記述タイプ | Other | |||||
内容記述 | Oxygen Club of California 2008 World Congress | |||||
発表年月日 | ||||||
日付 | 2008-03-15 | |||||
日付タイプ | Issued |