WEKO3
アイテム
{"_buckets": {"deposit": "8c06292a-0bfe-45fd-8797-7a4cd3af135f"}, "_deposit": {"created_by": 1, "id": "68581", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "68581"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00068581", "sets": ["28"]}, "author_link": ["673094", "673087", "673093", "673083", "673085", "673091", "673089", "673095", "673082", "673079", "673090", "673086", "673081", "673084", "673080", "673088", "673092", "673078"], "item_10005_date_7": {"attribute_name": "発表年月日", "attribute_value_mlt": [{"subitem_date_issued_datetime": "2006-04-09", "subitem_date_issued_type": "Issued"}]}, "item_10005_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "【目的】MRI技術の進歩により、脳以外の体幹部の拡散強調MRI画像が実用性を持つようになった。30名の体幹部の骨軟部腫瘍の症例に対して、拡散強調画像を撮像し、信号強度、異常の範囲をSE, Gradient ECHO法を中心としたルーチンのMRI画像と比較した。【対象・方法】対象は、2005年度に、放射線治療を目的とした来院した30例の骨軟部腫瘍の症例である。放射線治療前のMRI画像である。病理組織は、MFH, Chordoma, Chondrosarcoma, MPNST, Osteosarcoma, Ewing Sarcoma, Melanoma等である。使用した器械は、Philips社の1.5T Achievaである。ルーチン画像としては、SE法を原則としたが、呼吸により移動がある臓器に対しては、Gradient ECHOを用いた。拡散強調画像法では、脂肪抑制法の併用を原則とした。呼吸による移動が生じる臓器には、自由呼吸下で、加算回数を増加させた。B値は800〜1000とした。【結果】拡散強調画像は、T2強調画像に類似した画像を呈した。しかし、悪性骨軟部腫瘍は、T2強調画像で低信号となることがあり、その場合でも、拡散強調画像は高信号を示した。myxomatous changeや液体成分の場合には、T2強調画像と逆転した画像が得られた。腫瘍の大きさは、SE, GRE画像に類似したが、コントラストが良好なため、T2強調画像や造影T1強調画像よりも腫瘍の進展範囲が明瞭な症例が認められた、逆にルーチン画像では異常のない骨内部が高信号となることがあり、骨転移との鑑別が必要な症例も認められた。【考察】T1強調画像、T2強調画像に続く新たなコントラストにより、診断精度が向上させられる可能性があると考えられた。", "subitem_description_type": "Abstract"}]}, "item_10005_description_6": {"attribute_name": "会議概要(会議名, 開催地, 会期, 主催者等)", "attribute_value_mlt": [{"subitem_description": "第65回日本医学放射線学会学術集会", "subitem_description_type": "Other"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "神立, 進"}], "nameIdentifiers": [{"nameIdentifier": "673078", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "岸本, 理和"}], "nameIdentifiers": [{"nameIdentifier": "673079", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "小松, 秀平"}], "nameIdentifiers": [{"nameIdentifier": "673080", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "伊藤, 慎悟"}], "nameIdentifiers": [{"nameIdentifier": "673081", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "鎌田, 正"}], "nameIdentifiers": [{"nameIdentifier": "673082", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "今井, 礼子"}], "nameIdentifiers": [{"nameIdentifier": "673083", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "溝江, 純悦"}], "nameIdentifiers": [{"nameIdentifier": "673084", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "柳, 剛"}], "nameIdentifiers": [{"nameIdentifier": "673085", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "辻井, 博彦"}], "nameIdentifiers": [{"nameIdentifier": "673086", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "神立 進", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "673087", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "岸本 理和", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "673088", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "小松 秀平", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "673089", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "伊藤 慎悟", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "673090", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "鎌田 正", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "673091", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "今井 礼子", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "673092", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "溝江 純悦", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "673093", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "柳 剛", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "673094", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "辻井 博彦", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "673095", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference object", "resourceuri": "http://purl.org/coar/resource_type/c_c94f"}]}, "item_title": "拡散強調MRI画像による骨軟部腫瘍の描出", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "拡散強調MRI画像による骨軟部腫瘍の描出"}]}, "item_type_id": "10005", "owner": "1", "path": ["28"], "permalink_uri": "https://repo.qst.go.jp/records/68581", "pubdate": {"attribute_name": "公開日", "attribute_value": "2006-07-07"}, "publish_date": "2006-07-07", "publish_status": "0", "recid": "68581", "relation": {}, "relation_version_is_last": true, "title": ["拡散強調MRI画像による骨軟部腫瘍の描出"], "weko_shared_id": -1}
拡散強調MRI画像による骨軟部腫瘍の描出
https://repo.qst.go.jp/records/68581
https://repo.qst.go.jp/records/6858195862a8f-ca96-4b45-8d25-1db8730f0e9d
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2006-07-07 | |||||
タイトル | ||||||
タイトル | 拡散強調MRI画像による骨軟部腫瘍の描出 | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
神立, 進
× 神立, 進× 岸本, 理和× 小松, 秀平× 伊藤, 慎悟× 鎌田, 正× 今井, 礼子× 溝江, 純悦× 柳, 剛× 辻井, 博彦× 神立 進× 岸本 理和× 小松 秀平× 伊藤 慎悟× 鎌田 正× 今井 礼子× 溝江 純悦× 柳 剛× 辻井 博彦 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | 【目的】MRI技術の進歩により、脳以外の体幹部の拡散強調MRI画像が実用性を持つようになった。30名の体幹部の骨軟部腫瘍の症例に対して、拡散強調画像を撮像し、信号強度、異常の範囲をSE, Gradient ECHO法を中心としたルーチンのMRI画像と比較した。【対象・方法】対象は、2005年度に、放射線治療を目的とした来院した30例の骨軟部腫瘍の症例である。放射線治療前のMRI画像である。病理組織は、MFH, Chordoma, Chondrosarcoma, MPNST, Osteosarcoma, Ewing Sarcoma, Melanoma等である。使用した器械は、Philips社の1.5T Achievaである。ルーチン画像としては、SE法を原則としたが、呼吸により移動がある臓器に対しては、Gradient ECHOを用いた。拡散強調画像法では、脂肪抑制法の併用を原則とした。呼吸による移動が生じる臓器には、自由呼吸下で、加算回数を増加させた。B値は800〜1000とした。【結果】拡散強調画像は、T2強調画像に類似した画像を呈した。しかし、悪性骨軟部腫瘍は、T2強調画像で低信号となることがあり、その場合でも、拡散強調画像は高信号を示した。myxomatous changeや液体成分の場合には、T2強調画像と逆転した画像が得られた。腫瘍の大きさは、SE, GRE画像に類似したが、コントラストが良好なため、T2強調画像や造影T1強調画像よりも腫瘍の進展範囲が明瞭な症例が認められた、逆にルーチン画像では異常のない骨内部が高信号となることがあり、骨転移との鑑別が必要な症例も認められた。【考察】T1強調画像、T2強調画像に続く新たなコントラストにより、診断精度が向上させられる可能性があると考えられた。 | |||||
会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
内容記述タイプ | Other | |||||
内容記述 | 第65回日本医学放射線学会学術集会 | |||||
発表年月日 | ||||||
日付 | 2006-04-09 | |||||
日付タイプ | Issued |