WEKO3
アイテム
{"_buckets": {"deposit": "fdb07d01-19d7-4df3-bf92-ac8df991d647"}, "_deposit": {"created_by": 1, "id": "66028", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "66028"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00066028", "sets": ["29"]}, "author_link": ["776212", "776208", "776210", "776216", "776222", "776218", "776213", "776223", "776209", "776221", "776224", "776219", "776207", "776215", "776217", "776211", "776220", "776214"], "item_10005_date_7": {"attribute_name": "発表年月日", "attribute_value_mlt": [{"subitem_date_issued_datetime": "2016-11-05", "subitem_date_issued_type": "Issued"}]}, "item_10005_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Dementia is a severe problem in aging societies. There is a strong potential demand for high-sensitivity, high-resolution, and low-cost brain positron emission tomography (PET) imaging for its early diagnosis. Therefore, we have proposed the helmet-chin PET, a novel geometry for high-sensitivity brain imaging based on a hemispheric arrangement of detectors. For a proof-of-concept, we developed the first prototype using 4-layered depth-of-interaction (DOI) detectors. The helmet-chin PET prototype used 54 DOI detectors, each of which consisted of 16×16×4 Zr-doped GSO crystals (2.8×2.8×7.5 mm3) and a high sensitivity 64-channel flat-panel photomultiplier tube. In the prototype, 47 detectors were used to form a hemisphere of 25 cm inner diameter and 50 cm outer diameter, and 7 detectors were used for the chin detector. In this study, we conducted the first clinical test with a healthy volunteer. First, we compared sensitivity with a whole-body time-of-flight-PET (Biograph mCT Flow 64-4R PET/CT system, Siemens Medical Solutions USA, Inc.) to determine injection activity. As a result, the sensitivity of the helmet-chin PET prototype for the brain region was almost twice as high as that of the mCT, even though the number of detectors was less than 30% that of the mCT. Then a healthy volunteer was measured by the mCT for 15 min beginning 60 min after 18F-FDG injection of 70 MBq and by the helmet-chin PET for 18 min beginning 85 min after the injection. For the first clinical test, we could obtain a clear image of the brain with low radioactivity injection. We analyzed region of interest (ROI) values based on the anatomical structure. As a result, ROI values measured by the helmet-chin PET prototype and the mCT were in good agreement. The first clinical test showed promising performance of the helmet-chin PET for highly sensitive brain imaging.", "subitem_description_type": "Abstract"}]}, "item_10005_description_6": {"attribute_name": "会議概要(会議名, 開催地, 会期, 主催者等)", "attribute_value_mlt": [{"subitem_description": "2016 IEEE NSS/MIC", "subitem_description_type": "Other"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Tashima, Hideaki"}], "nameIdentifiers": [{"nameIdentifier": "776207", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yoshida, Eiji"}], "nameIdentifiers": [{"nameIdentifier": "776208", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Iwao, Yuma"}], "nameIdentifiers": [{"nameIdentifier": "776209", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Wakizaka, Hidekatsu"}], "nameIdentifiers": [{"nameIdentifier": "776210", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tazawa, Shusaku"}], "nameIdentifiers": [{"nameIdentifier": "776211", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Seki, Chie"}], "nameIdentifiers": [{"nameIdentifier": "776212", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kimura, Yasuyuki"}], "nameIdentifiers": [{"nameIdentifier": "776213", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Suhara, Tetsuya"}], "nameIdentifiers": [{"nameIdentifier": "776214", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yamaya, Taiga"}], "nameIdentifiers": [{"nameIdentifier": "776215", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tashima, Hideaki", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "776216", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yoshida, Eiji", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "776217", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Iwao, Yuma", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "776218", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Wakizaka, Hidekatsu", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "776219", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tazawa, Shusaku", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "776220", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Seki, Chie", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "776221", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kimura, Yasuyuki", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "776222", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Suhara, Tetsuya", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "776223", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yamaya, Taiga", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "776224", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference object", "resourceuri": "http://purl.org/coar/resource_type/c_c94f"}]}, "item_title": "First Clinical Test of the Helmet-Chin PET Prototype", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "First Clinical Test of the Helmet-Chin PET Prototype"}]}, "item_type_id": "10005", "owner": "1", "path": ["29"], "permalink_uri": "https://repo.qst.go.jp/records/66028", "pubdate": {"attribute_name": "公開日", "attribute_value": "2016-11-22"}, "publish_date": "2016-11-22", "publish_status": "0", "recid": "66028", "relation": {}, "relation_version_is_last": true, "title": ["First Clinical Test of the Helmet-Chin PET Prototype"], "weko_shared_id": -1}
First Clinical Test of the Helmet-Chin PET Prototype
https://repo.qst.go.jp/records/66028
https://repo.qst.go.jp/records/66028ee3d2b94-f479-4b78-a0c4-84efd669d7b9
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2016-11-22 | |||||
タイトル | ||||||
タイトル | First Clinical Test of the Helmet-Chin PET Prototype | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Tashima, Hideaki
× Tashima, Hideaki× Yoshida, Eiji× Iwao, Yuma× Wakizaka, Hidekatsu× Tazawa, Shusaku× Seki, Chie× Kimura, Yasuyuki× Suhara, Tetsuya× Yamaya, Taiga× Tashima, Hideaki× Yoshida, Eiji× Iwao, Yuma× Wakizaka, Hidekatsu× Tazawa, Shusaku× Seki, Chie× Kimura, Yasuyuki× Suhara, Tetsuya× Yamaya, Taiga |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Dementia is a severe problem in aging societies. There is a strong potential demand for high-sensitivity, high-resolution, and low-cost brain positron emission tomography (PET) imaging for its early diagnosis. Therefore, we have proposed the helmet-chin PET, a novel geometry for high-sensitivity brain imaging based on a hemispheric arrangement of detectors. For a proof-of-concept, we developed the first prototype using 4-layered depth-of-interaction (DOI) detectors. The helmet-chin PET prototype used 54 DOI detectors, each of which consisted of 16×16×4 Zr-doped GSO crystals (2.8×2.8×7.5 mm3) and a high sensitivity 64-channel flat-panel photomultiplier tube. In the prototype, 47 detectors were used to form a hemisphere of 25 cm inner diameter and 50 cm outer diameter, and 7 detectors were used for the chin detector. In this study, we conducted the first clinical test with a healthy volunteer. First, we compared sensitivity with a whole-body time-of-flight-PET (Biograph mCT Flow 64-4R PET/CT system, Siemens Medical Solutions USA, Inc.) to determine injection activity. As a result, the sensitivity of the helmet-chin PET prototype for the brain region was almost twice as high as that of the mCT, even though the number of detectors was less than 30% that of the mCT. Then a healthy volunteer was measured by the mCT for 15 min beginning 60 min after 18F-FDG injection of 70 MBq and by the helmet-chin PET for 18 min beginning 85 min after the injection. For the first clinical test, we could obtain a clear image of the brain with low radioactivity injection. We analyzed region of interest (ROI) values based on the anatomical structure. As a result, ROI values measured by the helmet-chin PET prototype and the mCT were in good agreement. The first clinical test showed promising performance of the helmet-chin PET for highly sensitive brain imaging. | |||||
会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
内容記述タイプ | Other | |||||
内容記述 | 2016 IEEE NSS/MIC | |||||
発表年月日 | ||||||
日付 | 2016-11-05 | |||||
日付タイプ | Issued |