WEKO3
アイテム
{"_buckets": {"deposit": "77c6a424-d5c5-4cd2-915e-a405c0076590"}, "_deposit": {"created_by": 1, "id": "64601", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "64601"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00064601", "sets": ["29"]}, "author_link": ["636633", "636637", "636638", "636635", "636639", "636634", "636636", "636632"], "item_10005_date_7": {"attribute_name": "発表年月日", "attribute_value_mlt": [{"subitem_date_issued_datetime": "2012-05-19", "subitem_date_issued_type": "Issued"}]}, "item_10005_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Purpose\nTo investigate whether a carbon ion beam has beneficial effects compared to X-rays by targeting putative human pancreatic cancer stem cells. \nMaterials\nHuman pancreatic cancer stem-like cells sorted from MiaPaca2, BxPc3, PANC1 and PK45 cells were treated with or without carbon ion or X-ray irradiation and then colony formation assay, spheroid formation assay, FACS analysis, as well as tumor formation analysis were performed. \nResults\nThe relative biological effectiveness (RBE) values of a carbon ion beam relative to X-ray for above pancreatic cancer cells at the D10 values were 1.71-2.18. The ability for colony, spheroid formation, and tumorigenicity from cancer stem-like CD44+/CD24+ cells is significantly higher than that from non-cancer stem-like cells CD44-/CD24-cells. FACS data showed that CD44+/CD24+ cells were more highly enriched after X-rays compared to carbon ion irradiation at isoeffective doses. The RBE values for the carbon ion beam relative to X-ray at the D10 levels for CD44+/CD24+ cells were 2.0-2.19. The number of gammaH2AX foci in CD44-/CD24- cells was higher than that of CD44+/CD24+ cells after irradiation with either X-ray or carbon ion beam. The number of gammaH2AX foci in CD44+/CD24+ cells was almost the same in the early time, but it persists for significantly longer in carbon ion beam irradiated cells compared to X-rays. \nConclusion\nCarbon ion beam has superior potential to kill pancreatic cancer stem cell-like cells, and prolonged induction of DNA damage might be one of the pivotal mechanisms of its high radiobiological effects compared to X-rays.", "subitem_description_type": "Abstract"}]}, "item_10005_description_6": {"attribute_name": "会議概要(会議名, 開催地, 会期, 主催者等)", "attribute_value_mlt": [{"subitem_description": "51st Annual Meeting of Particle Therapy Co-Operative Group (PTCOG51)", "subitem_description_type": "Other"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Sai, Sei"}], "nameIdentifiers": [{"nameIdentifier": "636632", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Oonishi, Kazuhiko"}], "nameIdentifiers": [{"nameIdentifier": "636633", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yamada, Shigeru"}], "nameIdentifiers": [{"nameIdentifier": "636634", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kamada, Tadashi"}], "nameIdentifiers": [{"nameIdentifier": "636635", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "崔 星", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "636636", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "大西 和彦", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "636637", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "山田 滋", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "636638", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "鎌田 正", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "636639", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference object", "resourceuri": "http://purl.org/coar/resource_type/c_c94f"}]}, "item_title": "Effects of Carbon Ion Beam on Pancreatic Cancer Stem-Like Cells In Vitro and In Vivo", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Effects of Carbon Ion Beam on Pancreatic Cancer Stem-Like Cells In Vitro and In Vivo"}]}, "item_type_id": "10005", "owner": "1", "path": ["29"], "permalink_uri": "https://repo.qst.go.jp/records/64601", "pubdate": {"attribute_name": "公開日", "attribute_value": "2012-06-01"}, "publish_date": "2012-06-01", "publish_status": "0", "recid": "64601", "relation": {}, "relation_version_is_last": true, "title": ["Effects of Carbon Ion Beam on Pancreatic Cancer Stem-Like Cells In Vitro and In Vivo"], "weko_shared_id": -1}
Effects of Carbon Ion Beam on Pancreatic Cancer Stem-Like Cells In Vitro and In Vivo
https://repo.qst.go.jp/records/64601
https://repo.qst.go.jp/records/646019b03c7a9-fe23-4794-94a9-50619bb522d8
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2012-06-01 | |||||
タイトル | ||||||
タイトル | Effects of Carbon Ion Beam on Pancreatic Cancer Stem-Like Cells In Vitro and In Vivo | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Sai, Sei
× Sai, Sei× Oonishi, Kazuhiko× Yamada, Shigeru× Kamada, Tadashi× 崔 星× 大西 和彦× 山田 滋× 鎌田 正 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Purpose To investigate whether a carbon ion beam has beneficial effects compared to X-rays by targeting putative human pancreatic cancer stem cells. Materials Human pancreatic cancer stem-like cells sorted from MiaPaca2, BxPc3, PANC1 and PK45 cells were treated with or without carbon ion or X-ray irradiation and then colony formation assay, spheroid formation assay, FACS analysis, as well as tumor formation analysis were performed. Results The relative biological effectiveness (RBE) values of a carbon ion beam relative to X-ray for above pancreatic cancer cells at the D10 values were 1.71-2.18. The ability for colony, spheroid formation, and tumorigenicity from cancer stem-like CD44+/CD24+ cells is significantly higher than that from non-cancer stem-like cells CD44-/CD24-cells. FACS data showed that CD44+/CD24+ cells were more highly enriched after X-rays compared to carbon ion irradiation at isoeffective doses. The RBE values for the carbon ion beam relative to X-ray at the D10 levels for CD44+/CD24+ cells were 2.0-2.19. The number of gammaH2AX foci in CD44-/CD24- cells was higher than that of CD44+/CD24+ cells after irradiation with either X-ray or carbon ion beam. The number of gammaH2AX foci in CD44+/CD24+ cells was almost the same in the early time, but it persists for significantly longer in carbon ion beam irradiated cells compared to X-rays. Conclusion Carbon ion beam has superior potential to kill pancreatic cancer stem cell-like cells, and prolonged induction of DNA damage might be one of the pivotal mechanisms of its high radiobiological effects compared to X-rays. |
|||||
会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
内容記述タイプ | Other | |||||
内容記述 | 51st Annual Meeting of Particle Therapy Co-Operative Group (PTCOG51) | |||||
発表年月日 | ||||||
日付 | 2012-05-19 | |||||
日付タイプ | Issued |