WEKO3
アイテム
{"_buckets": {"deposit": "ab99dac7-9080-43b2-b4a6-a0d3c6d9f958"}, "_deposit": {"created_by": 1, "id": "63253", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "63253"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00063253", "sets": ["29"]}, "author_link": ["624554", "624556", "624553", "624549", "624546", "624555", "624560", "624562", "624565", "624550", "624557", "624558", "624564", "624568", "624552", "624547", "624563", "624548", "624566", "624559", "624561", "624551", "624570", "624569", "624567"], "item_10005_date_7": {"attribute_name": "発表年月日", "attribute_value_mlt": [{"subitem_date_issued_datetime": "2009-04-14", "subitem_date_issued_type": "Issued"}]}, "item_10005_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Poupose: To determine if Cu-62 labeled diacetyl-bis (N (4)-methylthiosemicarbazone); (Cu-62-ATSM) imaging of tumor hypoxia is associated with C-11-methionine(MET) imaging of amino acid metabolism in cervical cancer.\n\\nMethod: PET/CT was performed in ten patients with cervical cancer for evaluation of both tumor hypoxia using Cu-62-ATSM and amino acid metabolism using MET. Histologically confirmed eight squamous cell carcinoma, four adenocarcima, two adenosquamous carcinoma and melanoma were enrolled in this study. Distribution of Cu-62-ATSM in tumor was compared with that of MET. The two-group system was evaluated the distribution of uptake as Matched (mostly matched with each other) and Mismatched (with each other). Tumor uptake of each tracer was also analyzed semi-quantitatively by Tumor-to-Normal-Tissue-Ratio (TNR).\n\\nResult: Matched and Mismatched-groups were 1 case (6.7%) and 14 cases (93.3%), respectively. In Mismatched-group, Cu-62-ATSM tend to accumulate around the distal margin of high MET uptake area in the tumor. Mean TNR was 9.5 in MET and 4.0 in Cu-62-ATSM, and thus image contrast between tumor and surrounding normal tissue was higher in MET PET/CT image than Cu-62-ATSM PET/CT image.\n\\nConclusion: Cu-62-ATSM and MET showed different distribution in most cases of cervical cancer. Cervical cancer had a greater tendency for the uptake of MET than Cu-62-ATSM.", "subitem_description_type": "Abstract"}]}, "item_10005_description_6": {"attribute_name": "会議概要(会議名, 開催地, 会期, 主催者等)", "attribute_value_mlt": [{"subitem_description": "H20年度HIMAC共同利用研究成果発表会", "subitem_description_type": "Other"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "長谷部, 充彦"}], "nameIdentifiers": [{"nameIdentifier": "624546", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "吉川, 京燦"}], "nameIdentifiers": [{"nameIdentifier": "624547", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "大橋, 靖也"}], "nameIdentifiers": [{"nameIdentifier": "624548", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "石川, 博之"}], "nameIdentifiers": [{"nameIdentifier": "624549", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "佐合, 賢治"}], "nameIdentifiers": [{"nameIdentifier": "624550", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "田巻, 倫明"}], "nameIdentifiers": [{"nameIdentifier": "624551", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "加藤, 真吾"}], "nameIdentifiers": [{"nameIdentifier": "624552", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "古川, 高子"}], "nameIdentifiers": [{"nameIdentifier": "624553", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "福村, 利光"}], "nameIdentifiers": [{"nameIdentifier": "624554", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "神立, 進"}], "nameIdentifiers": [{"nameIdentifier": "624555", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "鈴木, 和年"}], "nameIdentifiers": [{"nameIdentifier": "624556", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "佐賀, 恒夫"}], "nameIdentifiers": [{"nameIdentifier": "624557", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "辻井, 博彦"}], "nameIdentifiers": [{"nameIdentifier": "624558", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "長谷部 充彦", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "624559", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "吉川 京燦", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "624560", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "大橋 靖也", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "624561", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "石川 博之", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "624562", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "田巻 倫明", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "624563", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "加藤 眞吾", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "624564", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "古川 高子", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "624565", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "福村 利光", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "624566", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "神立 進", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "624567", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "鈴木 和年", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "624568", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "佐賀 恒夫", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "624569", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "辻井 博彦", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "624570", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference object", "resourceuri": "http://purl.org/coar/resource_type/c_c94f"}]}, "item_title": "子宮頸癌における重粒子線治療前後のMethionine-PETと62CuATSM-PET診断の比較研究", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "子宮頸癌における重粒子線治療前後のMethionine-PETと62CuATSM-PET診断の比較研究"}]}, "item_type_id": "10005", "owner": "1", "path": ["29"], "permalink_uri": "https://repo.qst.go.jp/records/63253", "pubdate": {"attribute_name": "公開日", "attribute_value": "2009-09-30"}, "publish_date": "2009-09-30", "publish_status": "0", "recid": "63253", "relation": {}, "relation_version_is_last": true, "title": ["子宮頸癌における重粒子線治療前後のMethionine-PETと62CuATSM-PET診断の比較研究"], "weko_shared_id": -1}
子宮頸癌における重粒子線治療前後のMethionine-PETと62CuATSM-PET診断の比較研究
https://repo.qst.go.jp/records/63253
https://repo.qst.go.jp/records/63253c1e1005c-41a5-4cbd-ac87-b7987a225451
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2009-09-30 | |||||
タイトル | ||||||
タイトル | 子宮頸癌における重粒子線治療前後のMethionine-PETと62CuATSM-PET診断の比較研究 | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
長谷部, 充彦
× 長谷部, 充彦× 吉川, 京燦× 大橋, 靖也× 石川, 博之× 佐合, 賢治× 田巻, 倫明× 加藤, 真吾× 古川, 高子× 福村, 利光× 神立, 進× 鈴木, 和年× 佐賀, 恒夫× 辻井, 博彦× 長谷部 充彦× 吉川 京燦× 大橋 靖也× 石川 博之× 田巻 倫明× 加藤 眞吾× 古川 高子× 福村 利光× 神立 進× 鈴木 和年× 佐賀 恒夫× 辻井 博彦 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Poupose: To determine if Cu-62 labeled diacetyl-bis (N (4)-methylthiosemicarbazone); (Cu-62-ATSM) imaging of tumor hypoxia is associated with C-11-methionine(MET) imaging of amino acid metabolism in cervical cancer. \nMethod: PET/CT was performed in ten patients with cervical cancer for evaluation of both tumor hypoxia using Cu-62-ATSM and amino acid metabolism using MET. Histologically confirmed eight squamous cell carcinoma, four adenocarcima, two adenosquamous carcinoma and melanoma were enrolled in this study. Distribution of Cu-62-ATSM in tumor was compared with that of MET. The two-group system was evaluated the distribution of uptake as Matched (mostly matched with each other) and Mismatched (with each other). Tumor uptake of each tracer was also analyzed semi-quantitatively by Tumor-to-Normal-Tissue-Ratio (TNR). \nResult: Matched and Mismatched-groups were 1 case (6.7%) and 14 cases (93.3%), respectively. In Mismatched-group, Cu-62-ATSM tend to accumulate around the distal margin of high MET uptake area in the tumor. Mean TNR was 9.5 in MET and 4.0 in Cu-62-ATSM, and thus image contrast between tumor and surrounding normal tissue was higher in MET PET/CT image than Cu-62-ATSM PET/CT image. \nConclusion: Cu-62-ATSM and MET showed different distribution in most cases of cervical cancer. Cervical cancer had a greater tendency for the uptake of MET than Cu-62-ATSM. |
|||||
会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
内容記述タイプ | Other | |||||
内容記述 | H20年度HIMAC共同利用研究成果発表会 | |||||
発表年月日 | ||||||
日付 | 2009-04-14 | |||||
日付タイプ | Issued |