{"_buckets": {"deposit": "6263412e-62ac-4f45-9ee3-6181901e103d"}, "_deposit": {"created_by": 1, "id": "56098", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "56098"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00056098", "sets": ["7"]}, "author_link": ["573950", "573951", "573949", "573948", "573953", "573952"], "item_10004_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2018-03", "bibliographicIssueDateType": "Issued"}, "bibliographicPageStart": "67", "bibliographic_titles": [{"bibliographic_title": "QST Takasaki Annual Report 2016"}]}]}, "item_10004_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Monitoring the beam profile is essential for stable accelerator operation in high-power hadron accelerator facilities. At the spallation neutron source of J-PARC, it is necessary to monitor the two-dimensional (2D) intensity distribution of high-energy proton beams on a target for reducing the on-target peak current density of the beam transported with the nonlinear optics. Therefore, we are developing a 2D profile monitor based on the luminescent materials. In this study, the degradation test of a luminescent material and the operation test of a new monitoring system using a radiation-tolerant optical fiber were performed at the cyclotron facility in TIARA.", "subitem_description_type": "Abstract"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "明午, 伸一郎"}], "nameIdentifiers": [{"nameIdentifier": "573948", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "松田, 洋樹"}], "nameIdentifiers": [{"nameIdentifier": "573949", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "湯山, 貴裕"}], "nameIdentifiers": [{"nameIdentifier": "573950", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "百合, 庸介"}], "nameIdentifiers": [{"nameIdentifier": "573951", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "湯山 貴裕", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "573952", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "百合 庸介", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "573953", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Development of Luminescence Profile Monitor for High-Intensity Proton Accelerator Facility", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Development of Luminescence Profile Monitor for High-Intensity Proton Accelerator Facility"}]}, "item_type_id": "10004", "owner": "1", "path": ["7"], "permalink_uri": "https://repo.qst.go.jp/records/56098", "pubdate": {"attribute_name": "公開日", "attribute_value": "2018-03-20"}, "publish_date": "2018-03-20", "publish_status": "0", "recid": "56098", "relation": {}, "relation_version_is_last": true, "title": ["Development of Luminescence Profile Monitor for High-Intensity Proton Accelerator Facility"], "weko_shared_id": -1}
Development of Luminescence Profile Monitor for High-Intensity Proton Accelerator Facility
https://repo.qst.go.jp/records/56098
https://repo.qst.go.jp/records/5609862b6397a-424f-4f4f-ac7f-c706a03ba3fc
Item type | 一般雑誌記事 / Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2018-03-20 | |||||
タイトル | ||||||
タイトル | Development of Luminescence Profile Monitor for High-Intensity Proton Accelerator Facility | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
明午, 伸一郎
× 明午, 伸一郎× 松田, 洋樹× 湯山, 貴裕× 百合, 庸介× 湯山 貴裕× 百合 庸介 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Monitoring the beam profile is essential for stable accelerator operation in high-power hadron accelerator facilities. At the spallation neutron source of J-PARC, it is necessary to monitor the two-dimensional (2D) intensity distribution of high-energy proton beams on a target for reducing the on-target peak current density of the beam transported with the nonlinear optics. Therefore, we are developing a 2D profile monitor based on the luminescent materials. In this study, the degradation test of a luminescent material and the operation test of a new monitoring system using a radiation-tolerant optical fiber were performed at the cyclotron facility in TIARA. | |||||
書誌情報 |