WEKO3
アイテム
{"_buckets": {"deposit": "af991bc1-e3b4-4e3a-9914-18534a598566"}, "_deposit": {"created_by": 1, "id": "55718", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "55718"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00055718", "sets": ["7"]}, "author_link": ["570139", "570133", "570138", "570135", "570137", "570134", "570130", "570140", "570141", "570136", "570131", "570132"], "item_10004_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2010-12", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "NIRS-M-237", "bibliographicPageEnd": "12", "bibliographicPageStart": "8", "bibliographicVolumeNumber": "2010", "bibliographic_titles": [{"bibliographic_title": "放射線医学総合研究所技術報告書"}]}]}, "item_10004_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "放射線医学総合研究所のX線棟に設置されているTITAN 320型X線発生装置を用いた生物体照射などの多くの実験には、200kVの管電圧のX線が使われている。この装置からの一次X線スペクトルは測定されていないが、最も単純に線質を表す物理量として半価層(HVL)がある。TITAN 320型X線発生装置に準備されている付加フィルター類の半価層を測定して、実効エネルギーを算定した。一方、アルミニウムと銅の厚さの異なる付加フィルターを通過した空気カーマの測定結果が、Birch and Marshall[1]のスペクトル計算式から算定した空気カーマと良く合うことを報告した[2]。従って、200kVのX線の線質を表す実効エネルギーを、半価層の測定とスペクトルの計算値から算出して比較検討した。\n線量関係の測定として、生物照射などが行われている位置での空気カーマの絶対線量の測定には応用技研製のAE-130L、c-110ファーマ型電離箱を用いている。しかし低エネルギー特性を改善するため、付加フィルターを通過後の空気カーマの測定はPrecision Radiation Measurement社のLC-0.8平行平板型電離箱でおこなった。50〜300kVの管電圧の付加フィルターを入れない時、60cmのFocus-Surface Distance (FSD)における空気カーマを測定した。また、シャッター開閉による線量への誤差も評価した。", "subitem_description_type": "Abstract"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "平岡, 武"}], "nameIdentifiers": [{"nameIdentifier": "570130", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "三井, 大輔"}], "nameIdentifiers": [{"nameIdentifier": "570131", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "酢屋, 徳啓"}], "nameIdentifiers": [{"nameIdentifier": "570132", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "石川, 剛弘"}], "nameIdentifiers": [{"nameIdentifier": "570133", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "濱野, 毅"}], "nameIdentifiers": [{"nameIdentifier": "570134", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "今関, 等"}], "nameIdentifiers": [{"nameIdentifier": "570135", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "平岡 武", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "570136", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "三井 大輔", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "570137", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "酢屋 徳啓", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "570138", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "石川 剛弘", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "570139", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "濱野 毅", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "570140", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "今関 等", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "570141", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "200kVX線の線質と線量の評価", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "200kVX線の線質と線量の評価"}]}, "item_type_id": "10004", "owner": "1", "path": ["7"], "permalink_uri": "https://repo.qst.go.jp/records/55718", "pubdate": {"attribute_name": "公開日", "attribute_value": "2011-02-25"}, "publish_date": "2011-02-25", "publish_status": "0", "recid": "55718", "relation": {}, "relation_version_is_last": true, "title": ["200kVX線の線質と線量の評価"], "weko_shared_id": -1}
200kVX線の線質と線量の評価
https://repo.qst.go.jp/records/55718
https://repo.qst.go.jp/records/557184654048c-981a-4c87-9837-e2abbaaeb188
Item type | 一般雑誌記事 / Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2011-02-25 | |||||
タイトル | ||||||
タイトル | 200kVX線の線質と線量の評価 | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
平岡, 武
× 平岡, 武× 三井, 大輔× 酢屋, 徳啓× 石川, 剛弘× 濱野, 毅× 今関, 等× 平岡 武× 三井 大輔× 酢屋 徳啓× 石川 剛弘× 濱野 毅× 今関 等 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | 放射線医学総合研究所のX線棟に設置されているTITAN 320型X線発生装置を用いた生物体照射などの多くの実験には、200kVの管電圧のX線が使われている。この装置からの一次X線スペクトルは測定されていないが、最も単純に線質を表す物理量として半価層(HVL)がある。TITAN 320型X線発生装置に準備されている付加フィルター類の半価層を測定して、実効エネルギーを算定した。一方、アルミニウムと銅の厚さの異なる付加フィルターを通過した空気カーマの測定結果が、Birch and Marshall[1]のスペクトル計算式から算定した空気カーマと良く合うことを報告した[2]。従って、200kVのX線の線質を表す実効エネルギーを、半価層の測定とスペクトルの計算値から算出して比較検討した。 線量関係の測定として、生物照射などが行われている位置での空気カーマの絶対線量の測定には応用技研製のAE-130L、c-110ファーマ型電離箱を用いている。しかし低エネルギー特性を改善するため、付加フィルターを通過後の空気カーマの測定はPrecision Radiation Measurement社のLC-0.8平行平板型電離箱でおこなった。50〜300kVの管電圧の付加フィルターを入れない時、60cmのFocus-Surface Distance (FSD)における空気カーマを測定した。また、シャッター開閉による線量への誤差も評価した。 |
|||||
書誌情報 |
放射線医学総合研究所技術報告書 巻 2010, 号 NIRS-M-237, p. 8-12, 発行日 2010-12 |