WEKO3
アイテム
{"_buckets": {"deposit": "4b922059-2bb4-44f4-afc6-8d4f11506301"}, "_deposit": {"created_by": 1, "id": "54482", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "54482"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00054482", "sets": ["2"]}, "author_link": ["556486", "556490", "556491", "556494", "556488", "556489", "556487", "556493", "556492", "556485"], "item_10003_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2011-05", "bibliographicIssueDateType": "Issued"}, "bibliographicPageStart": "237", "bibliographicVolumeNumber": "19", "bibliographic_titles": [{"bibliographic_title": "Proc. Intl. Soc. Mag. Reson. Med."}]}]}, "item_10003_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Recent studies on the utility of manganese have shown that manganese-enhanced MRI (MEMRI) can detect cellular alterations in tumor models [1][2]. In addition, the intercellular contrast agent MnCl2 has been successfully used to assess cell viability in heart ischemia [3], and cells can be easily labeled using Mn2+ in vitro [4]. Hasegawa et al. reported that MEMRI can reflect MnSOD over-expression in a tumor model [2]. Radiotherapy using high-energy x-rays treats malignancies with the intention of destroying or inactivating cells while preserving normal tissue integrity. We investigated the relationship between x-ray irradiation and Mn uptake in tumor cells and tested whether MEMRI can detect radiation-induced cell disturbances at an early stage both in vitro and in vivo.", "subitem_description_type": "Abstract"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Saito, Shigeyoshi"}], "nameIdentifiers": [{"nameIdentifier": "556485", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hasegawa, Sumitaka"}], "nameIdentifiers": [{"nameIdentifier": "556486", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Furukawa, Takako"}], "nameIdentifiers": [{"nameIdentifier": "556487", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Saga, Tsuneo"}], "nameIdentifiers": [{"nameIdentifier": "556488", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Aoki, Ichio"}], "nameIdentifiers": [{"nameIdentifier": "556489", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "齋藤 茂芳", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "556490", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "長谷川 純崇", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "556491", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "古川 高子", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "556492", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "佐賀 恒夫", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "556493", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "青木 伊知男", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "556494", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference paper", "resourceuri": "http://purl.org/coar/resource_type/c_5794"}]}, "item_title": "In-Vivo Detection of Cell Cycle Arrest Using Manganese-Enhanced MRI (MEMRI)", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "In-Vivo Detection of Cell Cycle Arrest Using Manganese-Enhanced MRI (MEMRI)"}]}, "item_type_id": "10003", "owner": "1", "path": ["2"], "permalink_uri": "https://repo.qst.go.jp/records/54482", "pubdate": {"attribute_name": "公開日", "attribute_value": "2014-02-17"}, "publish_date": "2014-02-17", "publish_status": "0", "recid": "54482", "relation": {}, "relation_version_is_last": true, "title": ["In-Vivo Detection of Cell Cycle Arrest Using Manganese-Enhanced MRI (MEMRI)"], "weko_shared_id": -1}
In-Vivo Detection of Cell Cycle Arrest Using Manganese-Enhanced MRI (MEMRI)
https://repo.qst.go.jp/records/54482
https://repo.qst.go.jp/records/54482bd1af22f-1404-4659-b3e5-ff561fd1d7d5
Item type | 会議発表論文 / Conference Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2014-02-17 | |||||
タイトル | ||||||
タイトル | In-Vivo Detection of Cell Cycle Arrest Using Manganese-Enhanced MRI (MEMRI) | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_5794 | |||||
資源タイプ | conference paper | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Saito, Shigeyoshi
× Saito, Shigeyoshi× Hasegawa, Sumitaka× Furukawa, Takako× Saga, Tsuneo× Aoki, Ichio× 齋藤 茂芳× 長谷川 純崇× 古川 高子× 佐賀 恒夫× 青木 伊知男 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Recent studies on the utility of manganese have shown that manganese-enhanced MRI (MEMRI) can detect cellular alterations in tumor models [1][2]. In addition, the intercellular contrast agent MnCl2 has been successfully used to assess cell viability in heart ischemia [3], and cells can be easily labeled using Mn2+ in vitro [4]. Hasegawa et al. reported that MEMRI can reflect MnSOD over-expression in a tumor model [2]. Radiotherapy using high-energy x-rays treats malignancies with the intention of destroying or inactivating cells while preserving normal tissue integrity. We investigated the relationship between x-ray irradiation and Mn uptake in tumor cells and tested whether MEMRI can detect radiation-induced cell disturbances at an early stage both in vitro and in vivo. | |||||
書誌情報 |
Proc. Intl. Soc. Mag. Reson. Med. 巻 19, p. 237, 発行日 2011-05 |