{"created":"2023-05-15T14:39:40.232862+00:00","id":54482,"links":{},"metadata":{"_buckets":{"deposit":"4b922059-2bb4-44f4-afc6-8d4f11506301"},"_deposit":{"created_by":1,"id":"54482","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"54482"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00054482","sets":["2"]},"author_link":["556486","556490","556491","556494","556488","556489","556487","556493","556492","556485"],"item_10003_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2011-05","bibliographicIssueDateType":"Issued"},"bibliographicPageStart":"237","bibliographicVolumeNumber":"19","bibliographic_titles":[{"bibliographic_title":"Proc. Intl. Soc. Mag. Reson. Med."}]}]},"item_10003_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Recent studies on the utility of manganese have shown that manganese-enhanced MRI (MEMRI) can detect cellular alterations in tumor models [1][2]. In addition, the intercellular contrast agent MnCl2 has been successfully used to assess cell viability in heart ischemia [3], and cells can be easily labeled using Mn2+ in vitro [4]. Hasegawa et al. reported that MEMRI can reflect MnSOD over-expression in a tumor model [2]. Radiotherapy using high-energy x-rays treats malignancies with the intention of destroying or inactivating cells while preserving normal tissue integrity. We investigated the relationship between x-ray irradiation and Mn uptake in tumor cells and tested whether MEMRI can detect radiation-induced cell disturbances at an early stage both in vitro and in vivo.","subitem_description_type":"Abstract"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Saito, Shigeyoshi"}],"nameIdentifiers":[{"nameIdentifier":"556485","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Hasegawa, Sumitaka"}],"nameIdentifiers":[{"nameIdentifier":"556486","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Furukawa, Takako"}],"nameIdentifiers":[{"nameIdentifier":"556487","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Saga, Tsuneo"}],"nameIdentifiers":[{"nameIdentifier":"556488","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Aoki, Ichio"}],"nameIdentifiers":[{"nameIdentifier":"556489","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"齋藤 茂芳","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"556490","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"長谷川 純崇","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"556491","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"古川 高子","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"556492","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"佐賀 恒夫","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"556493","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"青木 伊知男","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"556494","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference paper","resourceuri":"http://purl.org/coar/resource_type/c_5794"}]},"item_title":"In-Vivo Detection of Cell Cycle Arrest Using Manganese-Enhanced MRI (MEMRI)","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"In-Vivo Detection of Cell Cycle Arrest Using Manganese-Enhanced MRI (MEMRI)"}]},"item_type_id":"10003","owner":"1","path":["2"],"pubdate":{"attribute_name":"公開日","attribute_value":"2014-02-17"},"publish_date":"2014-02-17","publish_status":"0","recid":"54482","relation_version_is_last":true,"title":["In-Vivo Detection of Cell Cycle Arrest Using Manganese-Enhanced MRI (MEMRI)"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T23:00:25.497862+00:00"}