WEKO3
アイテム
{"_buckets": {"deposit": "27a29cd8-ad31-46e2-bfea-5a2eb787059e"}, "_deposit": {"created_by": 1, "id": "54347", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "54347"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00054347", "sets": ["2"]}, "author_link": ["555166", "555168", "555170", "555167", "555172", "555173", "555169", "555171"], "item_10003_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2012-11", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "237", "bibliographicPageStart": "232", "bibliographicVolumeNumber": "2012-6", "bibliographic_titles": [{"bibliographic_title": "Proceedings of the Workshop on Environmental Radioactivity (KEK Proceedings)"}]}]}, "item_10003_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "小型OSL線量読取装置(microStar)により低線量の繰り返し測定、積算線量測定、環境放射線測定の実測を行い、小型OSL線量計測システムの環境放射線測定への適用性を検証した。実験には環境放射線測定用線量計(EXタイプ)を用い、放射線医学総合研究所のCs-137線源(74GBq)を用いて試験照射を行い、microStar読取装置で線量を読み取った。JISにおいて定められた一般環境放射線測定における基準線量は0.3mGyであるので、10個の線量計に対し0.3mGyの照射、読み取り、アニールを100回繰り返した結果、測定回ごとの測定値の平均はプラスマイナス10%の範囲内にあり、標準偏差もプラスマイナス10%を超えることが無かった。", "subitem_description_type": "Abstract"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "小林, 育夫"}], "nameIdentifiers": [{"nameIdentifier": "555166", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "岡崎, 徹"}], "nameIdentifiers": [{"nameIdentifier": "555167", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Passmore, Chris"}], "nameIdentifiers": [{"nameIdentifier": "555168", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "矢島, 千秋"}], "nameIdentifiers": [{"nameIdentifier": "555169", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "保田, 浩志"}], "nameIdentifiers": [{"nameIdentifier": "555170", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "小林 育夫", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "555171", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "矢島 千秋", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "555172", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "保田 浩志", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "555173", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference paper", "resourceuri": "http://purl.org/coar/resource_type/c_5794"}]}, "item_title": "小型OSL線量読取装置による環境放射線測定", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "小型OSL線量読取装置による環境放射線測定"}]}, "item_type_id": "10003", "owner": "1", "path": ["2"], "permalink_uri": "https://repo.qst.go.jp/records/54347", "pubdate": {"attribute_name": "公開日", "attribute_value": "2012-12-19"}, "publish_date": "2012-12-19", "publish_status": "0", "recid": "54347", "relation": {}, "relation_version_is_last": true, "title": ["小型OSL線量読取装置による環境放射線測定"], "weko_shared_id": -1}
小型OSL線量読取装置による環境放射線測定
https://repo.qst.go.jp/records/54347
https://repo.qst.go.jp/records/54347355852d9-ba48-4b9f-875d-c140c5cfe3db
Item type | 会議発表論文 / Conference Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2012-12-19 | |||||
タイトル | ||||||
タイトル | 小型OSL線量読取装置による環境放射線測定 | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_5794 | |||||
資源タイプ | conference paper | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
小林, 育夫
× 小林, 育夫× 岡崎, 徹× Passmore, Chris× 矢島, 千秋× 保田, 浩志× 小林 育夫× 矢島 千秋× 保田 浩志 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | 小型OSL線量読取装置(microStar)により低線量の繰り返し測定、積算線量測定、環境放射線測定の実測を行い、小型OSL線量計測システムの環境放射線測定への適用性を検証した。実験には環境放射線測定用線量計(EXタイプ)を用い、放射線医学総合研究所のCs-137線源(74GBq)を用いて試験照射を行い、microStar読取装置で線量を読み取った。JISにおいて定められた一般環境放射線測定における基準線量は0.3mGyであるので、10個の線量計に対し0.3mGyの照射、読み取り、アニールを100回繰り返した結果、測定回ごとの測定値の平均はプラスマイナス10%の範囲内にあり、標準偏差もプラスマイナス10%を超えることが無かった。 | |||||
書誌情報 |
Proceedings of the Workshop on Environmental Radioactivity (KEK Proceedings) 巻 2012-6, p. 232-237, 発行日 2012-11 |