{"created":"2023-05-15T14:39:34.234489+00:00","id":54347,"links":{},"metadata":{"_buckets":{"deposit":"27a29cd8-ad31-46e2-bfea-5a2eb787059e"},"_deposit":{"created_by":1,"id":"54347","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"54347"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00054347","sets":["2"]},"author_link":["555166","555168","555170","555167","555172","555173","555169","555171"],"item_10003_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2012-11","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"237","bibliographicPageStart":"232","bibliographicVolumeNumber":"2012-6","bibliographic_titles":[{"bibliographic_title":"Proceedings of the Workshop on Environmental Radioactivity (KEK Proceedings)"}]}]},"item_10003_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"小型OSL線量読取装置(microStar)により低線量の繰り返し測定、積算線量測定、環境放射線測定の実測を行い、小型OSL線量計測システムの環境放射線測定への適用性を検証した。実験には環境放射線測定用線量計(EXタイプ)を用い、放射線医学総合研究所のCs-137線源(74GBq)を用いて試験照射を行い、microStar読取装置で線量を読み取った。JISにおいて定められた一般環境放射線測定における基準線量は0.3mGyであるので、10個の線量計に対し0.3mGyの照射、読み取り、アニールを100回繰り返した結果、測定回ごとの測定値の平均はプラスマイナス10%の範囲内にあり、標準偏差もプラスマイナス10%を超えることが無かった。","subitem_description_type":"Abstract"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"小林, 育夫"}],"nameIdentifiers":[{"nameIdentifier":"555166","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"岡崎, 徹"}],"nameIdentifiers":[{"nameIdentifier":"555167","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Passmore, Chris"}],"nameIdentifiers":[{"nameIdentifier":"555168","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"矢島, 千秋"}],"nameIdentifiers":[{"nameIdentifier":"555169","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"保田, 浩志"}],"nameIdentifiers":[{"nameIdentifier":"555170","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"小林 育夫","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"555171","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"矢島 千秋","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"555172","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"保田 浩志","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"555173","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference paper","resourceuri":"http://purl.org/coar/resource_type/c_5794"}]},"item_title":"小型OSL線量読取装置による環境放射線測定","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"小型OSL線量読取装置による環境放射線測定"}]},"item_type_id":"10003","owner":"1","path":["2"],"pubdate":{"attribute_name":"公開日","attribute_value":"2012-12-19"},"publish_date":"2012-12-19","publish_status":"0","recid":"54347","relation_version_is_last":true,"title":["小型OSL線量読取装置による環境放射線測定"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T23:02:01.160156+00:00"}