{"_buckets": {"deposit": "1a8741e9-67e0-49cd-99bb-8493ba73d05a"}, "_deposit": {"created_by": 1, "id": "53812", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "53812"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00053812", "sets": ["2"]}, "author_link": ["549208", "549209", "549210", "549201", "549204", "549212", "549211", "549214", "549205", "549207", "549213", "549203", "549206", "549215", "549202"], "item_10003_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2006-10", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "561", "bibliographicPageStart": "557", "bibliographicVolumeNumber": "4", "bibliographic_titles": [{"bibliographic_title": "Proceedings of the Asian and Oceanic Congress for Radiation Protection"}]}]}, "item_10003_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "The deposition of radon decay products in each respiratory region can \nincrease the lung cancer risk. Therefore, it is necessary to calculate the \ndeposition of radon decay products in respiratory regions. Nowadays, the \ndeposition in each respiratory region is able to be imitated using wire \nscreens in many studies. Those studies employed grab sampling, that is, \nsampling for short period less than several minutes. In natural environment, \nbecause the concentration of radon decay products changes with time, it is \nnecessary to measure continuously. In this study continuous dosimeter (CD) \nthat imitates deposition of radon decay products in respiratory regions by \nusing wire screens was developed for the purpose of estimation of the \ndeposition in respiratory regions in various environments. The ratio of \nactivities deposited in the simulated N and TB regions was calculated from \nresults of measurement by CD-R, CD-N and CD-TB continuously, so that after \naerosols were injected into the radon chamber, the ratio of N and TB \ndepositions decreased, and, in addition, N / (N+TB) deposition decreased. \nThese results indicated that CD-R, CD-N and CD-TB could measure the change \nof deposition ratio with time.", "subitem_description_type": "Abstract"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Iwaoka, Kazuki"}], "nameIdentifiers": [{"nameIdentifier": "549201", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tokonami, Shinji"}], "nameIdentifiers": [{"nameIdentifier": "549202", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ishikawa, Tetsuo"}], "nameIdentifiers": [{"nameIdentifier": "549203", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kobayashi, Yosuke"}], "nameIdentifiers": [{"nameIdentifier": "549204", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Takahashi, Hiroyuki"}], "nameIdentifiers": [{"nameIdentifier": "549205", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yatabe, Yoshinori"}], "nameIdentifiers": [{"nameIdentifier": "549206", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yonehara, Hidenori"}], "nameIdentifiers": [{"nameIdentifier": "549207", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Doi, Masahiro"}], "nameIdentifiers": [{"nameIdentifier": "549208", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "岩岡 和輝", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "549209", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "床次 眞司", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "549210", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "石川 徹夫", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "549211", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "小林 羊佐", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "549212", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "谷田部 慶憲", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "549213", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "米原 英典", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "549214", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "土居 雅広", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "549215", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference paper", "resourceuri": "http://purl.org/coar/resource_type/c_5794"}]}, "item_title": "Development of Continuous Radon Bronchial Dosimeter", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Development of Continuous Radon Bronchial Dosimeter"}]}, "item_type_id": "10003", "owner": "1", "path": ["2"], "permalink_uri": "https://repo.qst.go.jp/records/53812", "pubdate": {"attribute_name": "公開日", "attribute_value": "2007-02-27"}, "publish_date": "2007-02-27", "publish_status": "0", "recid": "53812", "relation": {}, "relation_version_is_last": true, "title": ["Development of Continuous Radon Bronchial Dosimeter"], "weko_shared_id": -1}
Development of Continuous Radon Bronchial Dosimeter
https://repo.qst.go.jp/records/53812
https://repo.qst.go.jp/records/5381288a6cfd3-adc6-4bde-9a84-74cb4f3e6b5d
Item type | 会議発表論文 / Conference Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2007-02-27 | |||||
タイトル | ||||||
タイトル | Development of Continuous Radon Bronchial Dosimeter | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_5794 | |||||
資源タイプ | conference paper | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Iwaoka, Kazuki
× Iwaoka, Kazuki× Tokonami, Shinji× Ishikawa, Tetsuo× Kobayashi, Yosuke× Takahashi, Hiroyuki× Yatabe, Yoshinori× Yonehara, Hidenori× Doi, Masahiro× 岩岡 和輝× 床次 眞司× 石川 徹夫× 小林 羊佐× 谷田部 慶憲× 米原 英典× 土居 雅広 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | The deposition of radon decay products in each respiratory region can increase the lung cancer risk. Therefore, it is necessary to calculate the deposition of radon decay products in respiratory regions. Nowadays, the deposition in each respiratory region is able to be imitated using wire screens in many studies. Those studies employed grab sampling, that is, sampling for short period less than several minutes. In natural environment, because the concentration of radon decay products changes with time, it is necessary to measure continuously. In this study continuous dosimeter (CD) that imitates deposition of radon decay products in respiratory regions by using wire screens was developed for the purpose of estimation of the deposition in respiratory regions in various environments. The ratio of activities deposited in the simulated N and TB regions was calculated from results of measurement by CD-R, CD-N and CD-TB continuously, so that after aerosols were injected into the radon chamber, the ratio of N and TB depositions decreased, and, in addition, N / (N+TB) deposition decreased. These results indicated that CD-R, CD-N and CD-TB could measure the change of deposition ratio with time. |
|||||