WEKO3
アイテム
{"_buckets": {"deposit": "9d3039ef-622e-494d-a866-36c973d28750"}, "_deposit": {"created_by": 1, "id": "47565", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "47565"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00047565", "sets": ["1"]}, "author_link": ["476776", "476786", "476782", "476775", "476774", "476777", "476778", "476784", "476780", "476785", "476783", "476773", "476779", "476781", "476788", "476787"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2016-07", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "11", "bibliographicPageEnd": "691", "bibliographicPageStart": "685", "bibliographicVolumeNumber": "43", "bibliographic_titles": [{"bibliographic_title": "Nuclear Medicine and Biology"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Introduction\nCopper-64 is an attractive radionuclide for positron emission tomography and is emerging as a radiotherapeutic agent. The demand of 64Cu with low metallic impurities has increased because of its wide applications when incorporated with antibodies, peptides, and proteins. In this study, we propose a new separation method to produce high-quality 64Cu using a cation exchange column, as well as an automated separation system suitable for large-scale production.\n\\nMethods\n64Cu was produced from an electrodeposited 64Ni target via the 64Ni(p,n)-reaction with a 24 MeV HH+ beam at 10 eμA (electrical microampere) conducted for 1–3 h. The irradiated target was transported to a hot cell and disassembled remotely. 64Cu was separated by a solvent mixture of HCl and acetone on a cation-exchange resin, AG50W-X8. The chemical purity of 64Cu final product was evaluated using ion-chromatography coupled with a UV detector and inductively coupled plasma mass spectroscopy for quality as well as metallic impurities.\n\\nResults\nWe obtained 64Cu in dried form at a yield of 5.2–13 GBq at the end of separation, or 521 ± 12 MBq/eμA h as the final product within 2.5 h of processing time. The metallic impurities were a satisfactory low level in the order of ppb. Major contaminants of Co and Ni were lower than those samples obtained by a widely accepted separation using an anion-exchange resin.\n\\nConclusion\nUsing a cation-exchange resin and a systematic operation, we successfully reduced the contamination level of the 64Cu product. As a straightforward separation method, which shortened the entire processing time, we obtained a satisfactory amount of high-quality 64Cu available for routine use.", "subitem_description_type": "Abstract"}]}, "item_8_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Elsevier"}]}, "item_8_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1016/j.nucmedbio.2016.07.007", "subitem_relation_type_select": "DOI"}}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Ohya, Tomoyuki"}], "nameIdentifiers": [{"nameIdentifier": "476773", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Nagatsu, Kotaro"}], "nameIdentifiers": [{"nameIdentifier": "476774", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Suzuki, Hisashi"}], "nameIdentifiers": [{"nameIdentifier": "476775", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Fukada, Masami"}], "nameIdentifiers": [{"nameIdentifier": "476776", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Minegishi, Katsuyuki"}], "nameIdentifiers": [{"nameIdentifier": "476777", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hanyu, Masayuki"}], "nameIdentifiers": [{"nameIdentifier": "476778", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Fukumura, Toshimitsu"}], "nameIdentifiers": [{"nameIdentifier": "476779", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Zhang, Ming-Rong"}], "nameIdentifiers": [{"nameIdentifier": "476780", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "大矢 智幸", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "476781", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "永津 弘太郎", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "476782", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "鈴木 寿", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "476783", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "深田 正美", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "476784", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "峯岸 克行", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "476785", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "破入 正行", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "476786", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "福村 利光", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "476787", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "張 明栄", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "476788", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Efficient preparation of high-quality 64Cu for routine use", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Efficient preparation of high-quality 64Cu for routine use"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/47565", "pubdate": {"attribute_name": "公開日", "attribute_value": "2016-10-12"}, "publish_date": "2016-10-12", "publish_status": "0", "recid": "47565", "relation": {}, "relation_version_is_last": true, "title": ["Efficient preparation of high-quality 64Cu for routine use"], "weko_shared_id": -1}
Efficient preparation of high-quality 64Cu for routine use
https://repo.qst.go.jp/records/47565
https://repo.qst.go.jp/records/475656854a926-60d0-4f97-a2ec-b21f1952d74b
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2016-10-12 | |||||
タイトル | ||||||
タイトル | Efficient preparation of high-quality 64Cu for routine use | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Ohya, Tomoyuki
× Ohya, Tomoyuki× Nagatsu, Kotaro× Suzuki, Hisashi× Fukada, Masami× Minegishi, Katsuyuki× Hanyu, Masayuki× Fukumura, Toshimitsu× Zhang, Ming-Rong× 大矢 智幸× 永津 弘太郎× 鈴木 寿× 深田 正美× 峯岸 克行× 破入 正行× 福村 利光× 張 明栄 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Introduction Copper-64 is an attractive radionuclide for positron emission tomography and is emerging as a radiotherapeutic agent. The demand of 64Cu with low metallic impurities has increased because of its wide applications when incorporated with antibodies, peptides, and proteins. In this study, we propose a new separation method to produce high-quality 64Cu using a cation exchange column, as well as an automated separation system suitable for large-scale production. \nMethods 64Cu was produced from an electrodeposited 64Ni target via the 64Ni(p,n)-reaction with a 24 MeV HH+ beam at 10 eμA (electrical microampere) conducted for 1–3 h. The irradiated target was transported to a hot cell and disassembled remotely. 64Cu was separated by a solvent mixture of HCl and acetone on a cation-exchange resin, AG50W-X8. The chemical purity of 64Cu final product was evaluated using ion-chromatography coupled with a UV detector and inductively coupled plasma mass spectroscopy for quality as well as metallic impurities. \nResults We obtained 64Cu in dried form at a yield of 5.2–13 GBq at the end of separation, or 521 ± 12 MBq/eμA h as the final product within 2.5 h of processing time. The metallic impurities were a satisfactory low level in the order of ppb. Major contaminants of Co and Ni were lower than those samples obtained by a widely accepted separation using an anion-exchange resin. \nConclusion Using a cation-exchange resin and a systematic operation, we successfully reduced the contamination level of the 64Cu product. As a straightforward separation method, which shortened the entire processing time, we obtained a satisfactory amount of high-quality 64Cu available for routine use. |
|||||
書誌情報 |
Nuclear Medicine and Biology 巻 43, 号 11, p. 685-691, 発行日 2016-07 |
|||||
出版者 | ||||||
出版者 | Elsevier | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1016/j.nucmedbio.2016.07.007 |