WEKO3
アイテム
Application of Al2O3:C+fibre dosimeters for 290 MeV/n carbon therapeutic beam dosimetry.
https://repo.qst.go.jp/records/47285
https://repo.qst.go.jp/records/472856c7c2cec-86b4-4890-a3e0-7ec22e3d8a8b
| Item type | 学術雑誌論文 / Journal Article(1) | |||||
|---|---|---|---|---|---|---|
| 公開日 | 2015-09-15 | |||||
| タイトル | ||||||
| タイトル | Application of Al2O3:C+fibre dosimeters for 290 MeV/n carbon therapeutic beam dosimetry. | |||||
| 言語 | ||||||
| 言語 | eng | |||||
| 資源タイプ | ||||||
| 資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
| 資源タイプ | journal article | |||||
| アクセス権 | ||||||
| アクセス権 | metadata only access | |||||
| アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
| 著者 |
Nascimento, L.F
× Nascimento, L.F× Vanhavere, F.× Kodaira, Satoshi× Kitamura, Hisashi× D.Verellen× Deene, Y.De× Vangavere Filip× 小平 聡× 北村 尚 |
|||||
| 抄録 | ||||||
| 内容記述タイプ | Abstract | |||||
| 内容記述 | The capability of radioluminescence (RL) dosimeters composed of carbon-doped aluminium oxide (Al2O3:C) detectors+optical fibre has been verified for absorbed dose-rate measurements during carbon radiotherapy. The RL signals from two separate Al2O3:C detectors (single crystal 'CG' and droplet 'P1') have been systematically measured and compared along the Bragg-curve and Spread-Out Bragg-Peak of 290 MeV/n carbon beams in the water. The absorbed dose response was assessed for the range of 0.5–10 Gy. For doses up to 6 Gy, we observed a linear response for both types of detectors, while for higher doses CG presented a more prominent supraliearity than P1. The RL response for low-LET protons in the entrance from the curve was found to closely resemble that observed for a clinical 6 MV X-ray beam, while it was found that P1 has a better agreement with the reference data from standard ionization chamber than CG. We observed a significant decrease in luminescence efficiency with LET in the Bragg peak region. The Al2O3:C RL luminescence efficiency differs from Al2O3:C OSL results, which implies that the signal can be corrected for LET dependency to match the correct SOBP and Bragg Peak. | |||||
| 書誌情報 |
Radiation Physics and Chemistry 巻 115, p. 75-80, 発行日 2015-10 |
|||||
| 出版者 | ||||||
| 出版者 | Elsevier | |||||
| ISSN | ||||||
| 収録物識別子タイプ | ISSN | |||||
| 収録物識別子 | 0969-806X | |||||
| DOI | ||||||
| 識別子タイプ | DOI | |||||
| 関連識別子 | 10.1016/j.radphyschem.2015.06.001 | |||||
| 関連サイト | ||||||
| 識別子タイプ | URI | |||||
| 関連識別子 | http://www.sciencedirect.com/science/article/pii/S0969806X15002297 | |||||
| 関連名称 | http://www.sciencedirect.com/science/article/pii/S0969806X15002297 | |||||