WEKO3
アイテム
{"_buckets": {"deposit": "438f0ab0-5002-4b23-a682-36e5de1ed418"}, "_deposit": {"created_by": 1, "id": "47175", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "47175"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00047175", "sets": ["1"]}, "author_link": ["471435", "471434", "471433", "471432", "471431"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2014-05", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "2", "bibliographicPageEnd": "263", "bibliographicPageStart": "258", "bibliographicVolumeNumber": "111", "bibliographic_titles": [{"bibliographic_title": "Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Purpose: We evaluated respiratory-gated carbon-ion beam dose distribution with boost irradiation in pancreatic therapy and compared results between the passive scattering and layer-stacking (a kind of semi-active scanning) irradiation techniques.\nMaterials and Methods: A total of 21 patients who were treated with conventional passive carbon-ion beam for pancreatic cancer underwent 4DCT imaging under free-breathing conditions. We defined two types of clinical target volume (CTV) for the initial and boost irradiations: CTV1 included the gross tumor volume (GTV) and peripheral organs, and CTV2 included the GTV only with an added uniform 2-mm margin. Planning target volumes 1 and 2 (PTV1 and PTV2) were calculated by adding the range variation considered internal margin defined by 4DCT to the respective CTVs. The initial prescribed dose (= 45.6Gy(RBE); RBE-weighted absorbed dose) was given to PTV1, and the boost dose was increased up to 26.4Gy(RBE) and given to PTV2. Dose assessments were compared between irradiation techniques using the paired t-test.\nResults: D95(GTV, CTV2) values were increased from 44.2Gy(RBE) with the prescribed dose of 45.6Gy(RBE) to 69.8Gy(RBE) with the prescribed dose of 72.0Gy(RBE) with both irradiations. Layer-stacking irradiation reduced excessive dosing to normal tissues compared with passive scattering irradiation, particularly for boost irradiation. 1st-2nd portion V20/V40, and stomach V20 values up to the prescribed dose of 48.0, 60.0, and 52.8Gy(RBE) were smaller than those in passive scattering irradiation without boost. Kidney V15/V30 (0.6%(P=0.05)/0.1%(P\u003e0.20) for right kidney, 10.4%(P\u003c0.01)/3.2%(P\u003c0.01) for left kidney), pancreas V20/V40 (88.6%(P\u003c0.01)/83.0%(P\u003c0.03)), duodenum 3rd-4th portion V20/V40 (23.6%(P\u003c0.01)/9.5%(P\u003e0.06)), and stomach V20 (16.3%(P\u003c0.01)) values in layer-stacking irradiation were smaller than those in passive scattering irradiation up to the prescribed dose of 72.0Gy(RBE) and also smaller than those with passive scattering irradiation without boost irradiation (= 45.6Gy(RBE)).\nConclusions: In pancreatic particle beam therapy, delivery of the prescribed dose by layer-stacking boost irradiation provides a greater reduction in excessive dose to normal tissues than delivery by passive scattering irradiation.", "subitem_description_type": "Abstract"}]}, "item_8_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Elsevier Scientific Publishers"}]}, "item_8_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "http://dx.doi.org/10.1016/j.radonc.2014.02.014", "subitem_relation_type_select": "DOI"}}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0167-8140", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Mori, Shinichiro"}], "nameIdentifiers": [{"nameIdentifier": "471431", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Shinoto, Makoto"}], "nameIdentifiers": [{"nameIdentifier": "471432", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yamada, Shigeru"}], "nameIdentifiers": [{"nameIdentifier": "471433", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "森 慎一郎", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "471434", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "山田 滋", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "471435", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Four-dimensional treatment planning in layer-stacking boost irradiation for carbon-ion pancreatic therapy", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Four-dimensional treatment planning in layer-stacking boost irradiation for carbon-ion pancreatic therapy"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/47175", "pubdate": {"attribute_name": "公開日", "attribute_value": "2015-07-23"}, "publish_date": "2015-07-23", "publish_status": "0", "recid": "47175", "relation": {}, "relation_version_is_last": true, "title": ["Four-dimensional treatment planning in layer-stacking boost irradiation for carbon-ion pancreatic therapy"], "weko_shared_id": -1}
Four-dimensional treatment planning in layer-stacking boost irradiation for carbon-ion pancreatic therapy
https://repo.qst.go.jp/records/47175
https://repo.qst.go.jp/records/47175397ce1b7-a228-430c-b29d-b235943a524f
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2015-07-23 | |||||
タイトル | ||||||
タイトル | Four-dimensional treatment planning in layer-stacking boost irradiation for carbon-ion pancreatic therapy | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Mori, Shinichiro
× Mori, Shinichiro× Shinoto, Makoto× Yamada, Shigeru× 森 慎一郎× 山田 滋 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Purpose: We evaluated respiratory-gated carbon-ion beam dose distribution with boost irradiation in pancreatic therapy and compared results between the passive scattering and layer-stacking (a kind of semi-active scanning) irradiation techniques. Materials and Methods: A total of 21 patients who were treated with conventional passive carbon-ion beam for pancreatic cancer underwent 4DCT imaging under free-breathing conditions. We defined two types of clinical target volume (CTV) for the initial and boost irradiations: CTV1 included the gross tumor volume (GTV) and peripheral organs, and CTV2 included the GTV only with an added uniform 2-mm margin. Planning target volumes 1 and 2 (PTV1 and PTV2) were calculated by adding the range variation considered internal margin defined by 4DCT to the respective CTVs. The initial prescribed dose (= 45.6Gy(RBE); RBE-weighted absorbed dose) was given to PTV1, and the boost dose was increased up to 26.4Gy(RBE) and given to PTV2. Dose assessments were compared between irradiation techniques using the paired t-test. Results: D95(GTV, CTV2) values were increased from 44.2Gy(RBE) with the prescribed dose of 45.6Gy(RBE) to 69.8Gy(RBE) with the prescribed dose of 72.0Gy(RBE) with both irradiations. Layer-stacking irradiation reduced excessive dosing to normal tissues compared with passive scattering irradiation, particularly for boost irradiation. 1st-2nd portion V20/V40, and stomach V20 values up to the prescribed dose of 48.0, 60.0, and 52.8Gy(RBE) were smaller than those in passive scattering irradiation without boost. Kidney V15/V30 (0.6%(P=0.05)/0.1%(P>0.20) for right kidney, 10.4%(P<0.01)/3.2%(P<0.01) for left kidney), pancreas V20/V40 (88.6%(P<0.01)/83.0%(P<0.03)), duodenum 3rd-4th portion V20/V40 (23.6%(P<0.01)/9.5%(P>0.06)), and stomach V20 (16.3%(P<0.01)) values in layer-stacking irradiation were smaller than those in passive scattering irradiation up to the prescribed dose of 72.0Gy(RBE) and also smaller than those with passive scattering irradiation without boost irradiation (= 45.6Gy(RBE)). Conclusions: In pancreatic particle beam therapy, delivery of the prescribed dose by layer-stacking boost irradiation provides a greater reduction in excessive dose to normal tissues than delivery by passive scattering irradiation. |
|||||
書誌情報 |
Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology 巻 111, 号 2, p. 258-263, 発行日 2014-05 |
|||||
出版者 | ||||||
出版者 | Elsevier Scientific Publishers | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0167-8140 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | http://dx.doi.org/10.1016/j.radonc.2014.02.014 |