WEKO3
アイテム
{"_buckets": {"deposit": "e89a9f44-ef42-48a6-8bcc-61b05acaedb5"}, "_deposit": {"created_by": 1, "id": "46393", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "46393"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00046393", "sets": ["1"]}, "author_link": ["462168", "462167", "462166"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2012-09", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "1", "bibliographicPageEnd": "90", "bibliographicPageStart": "85", "bibliographicVolumeNumber": "33", "bibliographic_titles": [{"bibliographic_title": "Journal of Cerebral Blood Flow and Metabolism"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "We have developed a feedback-controlled bolus plus infusion (FC-B/I) method for monitoring the interaction between positron\nemission tomography (PET) ligands and their specific target molecules with PET. The usefulness of the FC-B/I method was evaluated\nby the direct interaction between [11C]raclopride, a dopamine D2 receptor (D2R) ligand, and cold raclopride (10 and 100 mg/kg) in\nthe brains of conscious monkeys. The present results demonstrated that the FC-B/I method could achieve the equilibrium state of\n[11C]raclopride in the striatum of monkey brain, and also that the cold raclopride-induced reduction of [11C]raclopride binding to\nD2R was observed in a dose-dependent manner. Good correlations of distribution volume ratio of the striatum to cerebellum\nbetween the conventional bolus plus infusion (B/I) method and the FC-B/I method as well as between the conventional bolus\ninjection method and the FC-B/I method were observed. These results indicated that the system could be a useful tool for the\nevaluation of interaction between drug candidates and their target molecules like enzymes, receptors, and transporters by using of\ntheir specific PET ligands.", "subitem_description_type": "Abstract"}]}, "item_8_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1038/jcbfm.2012.134", "subitem_relation_type_select": "DOI"}}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0271-678X", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Kimura, Yuichi"}], "nameIdentifiers": [{"nameIdentifier": "462166", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "et.al"}], "nameIdentifiers": [{"nameIdentifier": "462167", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "木村 裕一", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "462168", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Feedback-controlled bolus plus infusion (FC-B/I) method for quantitative drug assessment in living brain with PET", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Feedback-controlled bolus plus infusion (FC-B/I) method for quantitative drug assessment in living brain with PET"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/46393", "pubdate": {"attribute_name": "公開日", "attribute_value": "2012-09-19"}, "publish_date": "2012-09-19", "publish_status": "0", "recid": "46393", "relation": {}, "relation_version_is_last": true, "title": ["Feedback-controlled bolus plus infusion (FC-B/I) method for quantitative drug assessment in living brain with PET"], "weko_shared_id": -1}
Feedback-controlled bolus plus infusion (FC-B/I) method for quantitative drug assessment in living brain with PET
https://repo.qst.go.jp/records/46393
https://repo.qst.go.jp/records/463934ab4f61b-87f3-4962-8eab-d3a6721cc7ce
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2012-09-19 | |||||
タイトル | ||||||
タイトル | Feedback-controlled bolus plus infusion (FC-B/I) method for quantitative drug assessment in living brain with PET | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Kimura, Yuichi
× Kimura, Yuichi× et.al× 木村 裕一 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | We have developed a feedback-controlled bolus plus infusion (FC-B/I) method for monitoring the interaction between positron emission tomography (PET) ligands and their specific target molecules with PET. The usefulness of the FC-B/I method was evaluated by the direct interaction between [11C]raclopride, a dopamine D2 receptor (D2R) ligand, and cold raclopride (10 and 100 mg/kg) in the brains of conscious monkeys. The present results demonstrated that the FC-B/I method could achieve the equilibrium state of [11C]raclopride in the striatum of monkey brain, and also that the cold raclopride-induced reduction of [11C]raclopride binding to D2R was observed in a dose-dependent manner. Good correlations of distribution volume ratio of the striatum to cerebellum between the conventional bolus plus infusion (B/I) method and the FC-B/I method as well as between the conventional bolus injection method and the FC-B/I method were observed. These results indicated that the system could be a useful tool for the evaluation of interaction between drug candidates and their target molecules like enzymes, receptors, and transporters by using of their specific PET ligands. |
|||||
書誌情報 |
Journal of Cerebral Blood Flow and Metabolism 巻 33, 号 1, p. 85-90, 発行日 2012-09 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0271-678X | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1038/jcbfm.2012.134 |