WEKO3
アイテム
{"_buckets": {"deposit": "bdc32741-3eb9-4780-8c06-a4c849dfc0e5"}, "_deposit": {"created_by": 1, "id": "44401", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "44401"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00044401", "sets": ["1"]}, "author_link": ["441204", "441203", "441198", "441194", "441195", "441199", "441200", "441201", "441202", "441196", "441197"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1995-04", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "4", "bibliographicPageEnd": "572", "bibliographicPageStart": "569", "bibliographicVolumeNumber": "33", "bibliographic_titles": [{"bibliographic_title": "Magnetic Resonance in Medicine"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "We used deuterium magnetic resonance imaging (2H MRI) to visualize water movement in the rabbit eye. Dynamic 2H MRI was obtained every 3.5 min at 2 tesla by FLASH pulse sequence (TR, 300 ms; TE, 10 ms; alpha = 90 degrees) with a slice thickness of 10 mm using a surface coil (4 cm in diameter). After topical administration (0.2 ml D2O), only the aqueous chamber was imaged, and the signals decreased mono-exponentially. The flow rate was 0.113/min, in agreement with that already reported. After intravenous administration of deuterated saline (3 ml/kg), the aqueous chamber became visible first during imaging, then by the vitreous body. The signals around the lens were only faintly detected. Thus, deuterium MRI was determined to be useful for visualizing water movement in the eye.", "subitem_description_type": "Abstract"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Obata, Takayuki"}], "nameIdentifiers": [{"nameIdentifier": "441194", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ikehira, Hiroo"}], "nameIdentifiers": [{"nameIdentifier": "441195", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Koga, Masahisa"}], "nameIdentifiers": [{"nameIdentifier": "441196", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yoshida, Katsuya"}], "nameIdentifiers": [{"nameIdentifier": "441197", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tateno, Yukio"}], "nameIdentifiers": [{"nameIdentifier": "441198", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "et.al"}], "nameIdentifiers": [{"nameIdentifier": "441199", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "小畠 隆行", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "441200", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "池平 博夫", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "441201", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "古賀 雅久", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "441202", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "吉田 勝哉", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "441203", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "舘野 之男", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "441204", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Deuterium magnetic resonance imaging of rabbit eye in vivo.", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Deuterium magnetic resonance imaging of rabbit eye in vivo."}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/44401", "pubdate": {"attribute_name": "公開日", "attribute_value": "2006-07-04"}, "publish_date": "2006-07-04", "publish_status": "0", "recid": "44401", "relation": {}, "relation_version_is_last": true, "title": ["Deuterium magnetic resonance imaging of rabbit eye in vivo."], "weko_shared_id": -1}
Deuterium magnetic resonance imaging of rabbit eye in vivo.
https://repo.qst.go.jp/records/44401
https://repo.qst.go.jp/records/4440153a0871a-8bb3-4c3e-ba82-9f8a55e141ff
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2006-07-04 | |||||
タイトル | ||||||
タイトル | Deuterium magnetic resonance imaging of rabbit eye in vivo. | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Obata, Takayuki
× Obata, Takayuki× Ikehira, Hiroo× Koga, Masahisa× Yoshida, Katsuya× Tateno, Yukio× et.al× 小畠 隆行× 池平 博夫× 古賀 雅久× 吉田 勝哉× 舘野 之男 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | We used deuterium magnetic resonance imaging (2H MRI) to visualize water movement in the rabbit eye. Dynamic 2H MRI was obtained every 3.5 min at 2 tesla by FLASH pulse sequence (TR, 300 ms; TE, 10 ms; alpha = 90 degrees) with a slice thickness of 10 mm using a surface coil (4 cm in diameter). After topical administration (0.2 ml D2O), only the aqueous chamber was imaged, and the signals decreased mono-exponentially. The flow rate was 0.113/min, in agreement with that already reported. After intravenous administration of deuterated saline (3 ml/kg), the aqueous chamber became visible first during imaging, then by the vitreous body. The signals around the lens were only faintly detected. Thus, deuterium MRI was determined to be useful for visualizing water movement in the eye. | |||||
書誌情報 |
Magnetic Resonance in Medicine 巻 33, 号 4, p. 569-572, 発行日 1995-04 |